1/14
Vocabulary practice flashcards covering fundamental concepts, margin definitions, quantitative indices, and planning techniques in conformal radiotherapy (CRT and 3D-CRT).
Homogeneity Index (HI)
A quantitative metric evaluating the steepness of the PTV DVH curve, calculated using the formula HI=DprescriptionD1%−D99%.
Dose Volume Histogram (DVH)
A graphical representation of the frequency distribution of radiation dose values across a 3D matrix of voxels in an anatomical structure, plotting structure volume against absorbed dose.
Homogeneity Index (HI)
A quantitative metric evaluating the steepness of the PTV DVH curve, calculated using the formula HI=DprescriptionD1%−D99%.
Digitally Reconstructed Radiograph (DRR)
A simulated 2D transmission radiograph calculated from CT dataset voxels, used as a baseline reference image for patient position verification before radiation delivery.
ICRU Reference Point
A designated point located in a region without steep dose gradients where the absorbed dose is clinically representative, accurately determinable, and typically placed at the isocenter in SAD setups.
Beam's Eye View (BEV)
A display projection of the patient's anatomy, contoured volumes, and beam-limiting devices as viewed along the central axis of the radiation beam from the radiation source.
Wedge Filter
A physical or virtual beam modifier used to tilt isodose lines across a treatment field to compensate for irregular patient contours or differential tissue thickness.
Field-in-Field (FiF) Technique
A conformal planning technique that involves using multiple static subfields with low weighting to shield hot spots and improve dose uniformity across the target volume.
Multileaf Collimator (MLC)
A motorized collimator assembly composed of adjustable high-density tungsten leaves designed to conform beam apertures to the shape of the target volume.
Density Override for Metal Artifacts
The treatment planning correction where severe imaging streak distortions from prostheses are contoured and assigned a uniform water-equivalent density to avoid dose calculation errors.
Tangential Field Alignment in Breast 3D-CRT
A planning technique where posterior edges of opposed tangent beams are precisely aligned to prevent beam divergence into the ipsilateral lung and heart.
Four-Field Box Technique
A standard arrangement using four orthogonal fields (0∘, 90∘, 180∘, and 270∘) with matched weights to deliver a uniform dose to deep-seated pelvic or abdominal targets.
Beam Weight
The relative fraction or percentage of the prescribed target dose contributed by an individual beam at the treatment plan normalization point.
Plan Normalization
The process in treatment planning of scaling beam doses so that a designated reference point, typically the isocenter, receives exactly 100% of the prescription dose.
Tissue Compensator
A device used in radiation therapy to modify the dose distribution by compensating for variations in tissue density or anatomy, ensuring uniform dose delivery to the target area.