Lesson 11: Current Trends in the Laboratory (pt 1)

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/38

encourage image

There's no tags or description

Looks like no tags are added yet.

39 Terms

1
New cards

Automation has 3 stages:

  • Pre-analytic

  • Analytic

  • Post-analytic


2
New cards

Pre-analytic Stages are:

  • Pneumatic Tube System

  • Barcoding

  • Microchip

  • Specimen Prep.


3
New cards

Analytic Stages are:

  • Clinical Chemistry

  • Immunochemistry & Immunology


4
New cards

A systems that propel cylindrical containers through networks of tubes.

Pneumatic Tube System

5
New cards

Pneumatic Tube System is also known as?

  • Pneumatic Tube Transport

  • Capsule Pipe Lines


6
New cards

A systems that propel cylindrical containers through networks of tubes by?

compressed air or by partial (rapid) vacuum.

7
New cards

Pneumatic Tube System are used for?

Rapid transporting solid objects (blood bags and blood samples in evacuated collection tubes).

8
New cards

Pneumatic Tube System requires close attention to the design to prevent _______ of the specimen.

hemolysis

9
New cards

__?__ is developing a new standard for the use of two-dimensional bar codes in clinical and anatomic pathology laboratories.

CLSI

10
New cards

Two-dimensional bar codes are better than one-dimensional bar codes because?

  • It encodes more data in smaller formats

  • Have greater reliability


11
New cards

Unequivocal _______ identification of each specimen is achieved in analysers with bar code readers.

positive

12
New cards

Researchers have developed ________, embedded in the plastic of the test tube and used to store all relevant information such as:

  • when and where a sample is from

  • patient's name.


Microchip


13
New cards

The use of whole blood in the assay system shortens the ___________ time.

Specimen Preparation

14
New cards

Automated or semi automated ______________ have been incorporated into automated systems to provide test results within minutes.

  • This is now commonly used for assays of electrolytes and other analytes.


ion-selective electrodes

15
New cards

Under clinal chem. Functionalities include:

  • Diverse assay menu

  • Methods of analytical detection

  • QC management

  • LIS connectivity


16
New cards
  • Automated instruments for large-volume laboratories have:


  • Improved efficiency

  • More physical plant requirements

  • More complex maintenance procedures


17
New cards

Immunochemistry & Immunology discussed methods for testing:

  • COVID-19 Antibody Testing

  • Molecular Diagnostic Testing for SARS-COV-2


18
New cards

Serologic tests detect _________ infection indirectly.

waning or past SARS CoV-2 virus

19
New cards

Serologic tests detect waning or past SARS CoV-2 virus infection indirectly by measuring the host's _______ to the virus.

humoral immune response



20
New cards

The strength of antibody response depends on:

  • Age

  • Nutritional status

  • Severity of disease

  • Medications or infections (like HIV) that suppress the immune system


21
New cards

Studies show that majority of patients develop antibody response only in the _____ week after onset of symptoms.

second

22
New cards

Antigenic targets used in Antibody testing:

  • Spike glycoprotein (S)

  • Nucleocapsid phosphoprotein (N)


23
New cards

Types of Antibody Testing:

  • Binding Antibody Detection

  • Neutralizing Antibody Detection


24
New cards

These tests use purified proteins of SARS-CoV-2, not live virus, and can be performed in lower biosafety level laboratories

Binding Antibody Detection



25
New cards

Depending on the complexity of assays, these tests can be performed ____ in a field setting or in a few hours in a laboratory.

rapidly

26
New cards

2 categories of Binding antibody detection tests:

  • POCT

  • LAB TESTS


27
New cards

Are lateral flow devices that detect:

  • IgG and IgM

  • Total antibody in serum, plasma, or whole blood


Point-of-care Tests (POCT)

28
New cards

Use ELISA or CLIA methods for antibody detection using blood samples.

Laboratory Tests

29
New cards

Based on:

  • Reagents

  • IgG, IgM, & IgA

(Can be detected separately/combined as total antibody)

Laboratory Tests

30
New cards

The test determines the functional ability of antibodies to prevent infection of virus in vitro.

Neutralizing Antibody Detection

31
New cards

Involves incubating serum/plasma with live virus followed by infection and incubation of cells.


Neutralizing Antibody Detection

32
New cards

Testing will require either BSL-3 or BSL-2 laboratories, depending on what form of the SARS-CoV-2 virus is used

Neutralizing Antibody Detection

33
New cards

2 Types of neutralization tests:

  • Virus Neutralization Tests (VNT)

  • Pseudovirus Neutralization Tests (pVNT)


34
New cards

This neutralization test includes:

  • plaque-reduction neutralization test

  • microneutralization


Virus Neutralization Tests (VNT)

35
New cards

This neutralization test uses a SARS-CoV-2 virus from a clinical isolate or recombinant SARS-CoV-2 expressing reporter proteins.

Virus Neutralization Tests (VNT)

36
New cards

Virus Neutralization Tests (VNT) requires BSL-3 laboratories and may take up to ___ days to complete

5

37
New cards

Virus Neutralization Tests (VNT) requires ______ labs and may take up to 5 days to complete.

BSL-3

38
New cards

This neutralization test use recombinant pseudoviruses (like vesicular stomatitis virus, VSV) that incorporate the S protein of SARS-CoV-2.

Pseudovirus Neutralization Tests (pVNT)

39
New cards

Pseudovirus Neutralization Tests (pVNT) can be performed in _______ labs depending on the VSV strain used.

BSL-2