1/90
Looks like no tags are added yet.

Relief Vent
A vertical vent line, the primary function of which is to provide additional circulation of air between the drainage and vent systems or to act as an auxiliary vent on a specially designed system such as a ''yoke vent" connection between the soil and vent stacks.
Developed Length
Developed length in plumbing is the true center-line length of a pipe path, measured along the actual curve, center, and turns of the pipe and fittings. Unlike a straight line point-to-point measurement, it accounts for every foot of pipe run and is often multiplied by a safety factor (e.g., 1.2) to estimate pressure drops across fittings
The length of a pipe along its centerline and fittings.
Sewer
A pipe or conduit for carrying sewage and wastewater

Indirect Waste Pipe
An indirect waste pipe is a drainage pipe that does not connect directly to the main sanitary sewer system. Instead, it discharges liquid waste through an open air gap or air break into an approved waste receptor, such as a floor sink, standpipe, or laundry tub, preventing sewage and sewer gases from contaminating food, ice, or appliances.
Common Uses and ApplicationsFood and Beverage Equipment: Food prep sinks, ice makers, commercial dishwashers, steam kettles, and dipper wells must use indirect waste to avoid bacterial contamination.
Residential Appliances: Clothes washers (via a standpipe) and domestic dishwashers frequently use indirect connections.Mechanical Equipment: Temperature relief valves, water heaters, boilers, and AC condensate lines drain indirectly to protect potable water and equipment.
It is a pipe that does not connect directly with the drainage system but conveys liquid wastes by discharging into a plumbing fixture, interceptor, or receptacle directly connected to the drainage system.

Stack Vent
The extension of a soil or waste stack above the highest horizontal drain connected to the stack. The uppermost end above the roof is called stack vent through roof (SVTR)
Air Break
A physical separation, which may be a low inlet into the indirect waste receptor from the fixture, appliance, or device indirectly connected.

Septic Tank
A water-tight receptacle which receives the discharge of a sanitary plumbing system or part thereof, designed and constructed to retain solids, digest organic matter through a period of detention and to allow the liquids to discharge into the soil outside of the tank through a system of open-jointed sub-surface pipings or a seepage pit meeting the requirements of this Code.
Liquid Waste
It is the discharge from any fixture, appliance, or appurtenance in connection with a plumbing system that does not receive fecal matter

Branch Interval
A length of soil or waste stack corresponding in general to a story height, but in no case less than 2.43 meters within which the horizontal branches from one floor or story of a building are connected to the stack
Board
Licensure Board for Master Plumbers

Ball Cock
A valve opened and closed by the fall and rise, respectively, of an attached ball floating on the surface of the liquid
higher than 449 degrees
Brazed Joint is any joint obtained by joining of metal parts with alloys which melt at temperatures ______ degrees centigrade, but lower than the melting temperature of the parts to be joined
Existing Work
The on-going installation of the plumbing system or any part thereof which has been installed prior to the effectivity of this Code.
Welded Joint or Seam
Any joint or seam obtained by the joining of metal parts in a plastic molten state.
Approved
Accepted or acceptable under an applicable specifications or standard stated or cited in this Code., or accepted as suitable for any proposed use under procedures and powers of the Administrative Authority.
Dual Vent
Unit Vent is synonymous to _____.

Wye
A hose connection with two-gated outlets permitting two connections of the same or smaller coupling diameter to be taken from a single supply line. Also, a pipe fitting of three branches that form the letter “Wye”
Combination Waste and Vent System
A specially designed system of waste piping embodying the horizontal wet venting of one or more sinks or floor drains by means of a common horizontal waste and vent pipe adequately sized to provide free movement of air above the flow line of the drain.
Main
Any system of continuous piping, which is the principal artery of the system where branches are connected.

A pipe fitting with adjacent reverse bends and shaped like the letter "S''
Double-bend fitting
Water Treatment
A device which conditions or treats water supply to improve water quality, remove suspended solids by filtration
Court
An open, unoccupied space, bounded on two (2) or more sides by the walls of the building. An inner court is a court entirely within the exterior walls of a building.

Mobile Home Park Sewer
That part of the horizontal piping of a sanitary drainage system which measures 0.6 meter downstream from the last mobile home site and conveys sewage to a public sewer, private sewer, individual sewage disposal system or other points of disposal
It is a sewer system collects and treats wastewater from individual lots using a municipal city connection, private lagoon, package treatment plant, or local septic tanks. Individual lot connections generally require a 3- to 4-inch wide pipe positioned slightly above ground and sealed tight.

Yoke Vent
The purpose of a yoke vent is pressure equalization, air balancing, and stack protection. It connects a drainage or soil stack to a nearby vent stack in tall buildings to stop sudden air pressure changes that can empty water traps
A pipe connecting upward from a soil or waste stack below the floor and below horizontal connection to an adjacent vent stack at a point above the floor and higher than the highest spill level of fixtures for preventing pressure changes in the stacks.

Battery of Fixtures
Any of two or more similar adjacent fixtures that discharge into a common horizontal soil or waste branch
Plumbing System
Includes all potable water supply and distribution pipes, all plumbing fixtures and traps; all sanitary and storm drainage systems; vent pipes, roof drains, leaders and downspouts; and all building drains and sewers, including their respective joints and connections; devices, receptacles, and appurtenances within the property; water lines in the premises: potable, tap, hot and chilled water pipings; potable water treating or using equipment; fuel gas piping; water heaters and vents for same.
Automatic Standpipe System
A standpipe that operates automatically by opening a hose valve.
Grade
It is the slope or fall of a line of pipe with reference to a horizontal plane. In drainage, it is usually expressed as the fall in centimeters per meter or percentage slope of pipe.
Jurisdiction
The Administrative Authority under the Department of Health, the Department of Public Works & Highways, the Department of Interior and Local Government, the City Mayors of Chartered Cities, Environmental Management Bureau (D.E.N.R), and other government: entities that regulate the practice of Registered & Licensed Master Plumbers.
Soldered Joint
A pipe joint obtained by joining metal parts with metallic mixtures or alloys which melt at a temperature below 427 degrees centigrade and above 149 degrees centigrade
Plumbing Appurtenance
A manufactured device or a prefabricated assembly or an on-the-job assembly of component parts, and serves as an adjunct to the basic piping system and plumbing fixtures. An appurtenance demands no additional water supply nor does it add any discharge load to a fixture or the drainage system. It performs some useful functions in the operation, maintenance, servicing, economy or safety of the plumbing system.
28.3 liters per minute ( 1 cu. ft./minute)
1 Fixture unit is equivalent to a rate of flow at ______
Polyethylene (PE)
Tube made of plastic material and colored black. The cross-sectional shape is circular and is denoted by its outside diameter or O.D.

Tapped Tee
A tee with the branch tapped to receive a threaded pipe or fittings

Return Bend
An open return bend usually made up two 90° bends with inside and outside threads, flanged or welded fittings; and applied also to a one hundred eighty degrees bend in copper tubings.
Slip Joint
An adjustable tubing connection, consisting of a compression nut, a friction ring, and a compression washer. designed to fit a threaded adapter fitting or a standard taper pipe thread
Person
A natural person, his heirs, executors, administrators or assigns; and also includes a firm, partnership or corporation, its or their successors or assigns or agents of any of the aforesaid
Backflow Connection
Condition or any arrangement whereby reverse flow can occur.
Conductor
A vertical rainwater conductor and a downspout are actually the exact same thing. "Downspout" is the common, everyday term used by homeowners, while "vertical rainwater conductor" (or simply "conductor") is the technical or architectural term used in building codes and plumbing plans to describe the pipe that carries water down from a roof.
A vertical pipe to convey rainwater
Seal
The vertical distance between the dip and the crown weir of a trap. Also, the water in the trap between the dip and the crown weir.
Caulking
Plugging an opening with oakum, lead, or other materials that are pounded into the annular space. Also, the material pounded into the annular opening.
Oakum
Hemp or old hemp rope soaked in oil or tar to make it waterproof.
Pollution
An impairment of the quality of the water to a degree which creates a hazard to public health and adversely affects the aesthetic and potable qualities of water for domestic use.
Vertical Pipe
Any pipe or fitting installed in a vertical position or which forms an angle of not more than forty-five (45) degrees with the vertical line.
Flooded
A fixture is flooded when the liquid therein rises to the flood-level rim
Pressure
The normal force exerted by a homogeneous liquid or gas, per unit of area on the wall of the container
Height of Building
The vertical distance from the "Grade Line" to the highest point of the coping of a flat roof or to the top line of a measured roof or to the average height of the highest gable of a pitch or hip-roof

Gate Valve
A valve in which the flow of water is cut off by means of a circular disc fitted against machine-smoothed faces, at right angles to the direction of flow. The disk is raised or lowered by means of a threaded stern connected to the handle of the valve. The opening in the valve is usually as large as the full bore of the pipe.

Grease Trap
A device designed to retain grease from one to a maximum of four fixtures.
Siphonage
A suction created by the flow of liquids in pipes. A pressure less than atmospheric.
Riser
A water supply pipe, which extends vertically to one full story or more to convey water into pipe branches or plumbing fixtures.
at least 1.4 cu. m.
Unconfined Space - A room space having a volume equal to ________ of the aggregate input rating of the fuel-burning appliance installed in that space. Rooms adjacent and open to the space where the appliance is installed, through openings not furnished with doors, are considered a part of the unconfined space.

Invert
The lowest portion of the interior part of any pipe or conduit that is not vertical.
less than 1.4 cu. m
Plumbing work in confined spaces involves tight or enclosed areas like sewer pits, utility vaults, crawlspaces, large pipelines, and tanks. These zones have limited entry and exit points and pose extreme risks, including toxic gases, low oxygen, and engulfment, requiring strict safety protocols and specialized tools.
Confined Space - A room or space having a volume of _______ with 250 kilogram calorie of the aggregate input rating of all fuel-burning appliances installed in that space
Grade
In Plumbing Code, referred to as "Pitch".
Storm Water
That portion of the rainfall or other precipitation which runs off over the earth surface after a storm.

Ferrule
A metallic sleeve, caulked or joined to an opening in a pipe, into which a plug is screwed that can be removed for cleaning or examining the interior of the pipe.

Latrine
A water closet consisting of a continuous trough containing water. The trough extends under two or more adjacent seats. Prohibited by health authorities for permanent installations
Sanitary Sewage
The wastewater containing human excrements and liquid household waste. Also called domestic sewage
30 cm and 7.5 cm
Gooseneck dimensions one end of which is about ___cm. long and the other end is about ___cm.
Back-Siphonage
The flowing back of used, contaminated, or polluted water from a plumbing fixture or vessel into a water supply pipe due to a negative pressure in such pipe.
Leaching Cesspool
A cesspool that is not watertight.

Absorption Field
A trench wider than 36 in (914 mm) containing coarse aggregate and two or
more distribution pipes through which the effluent from a septic tank May seep
into the surrounding soil. Also called seepage bed.
250 kilogram calorie
Confined Space - A room or space having a volume of less than 1.4 cu. m with ____ kilogram calorie of the aggregate input rating of all fuel-burning appliances installed in that space.
Vent Pipe
A pipe or opening used for ensuring the circulation of air in a plumbing system and for relieving the negative pressure exerted on trap seals.

Brazed Joint
Any joint obtained by joining of metal parts with alloys which melt at temperatures higher than 449 degrees centigrade, but lower than the melting temperature of the parts to be joined.
Bibb
Synonymous with faucet, cock, tap, plug, etc. The word "faucet" is preferred.
Private
In a classification of plumbing fixtures, "______" applies to plumbing fixtures in residences and apartments, to private bathrooms in hotels and hospitals, to restrooms in commercial establishments for restricted use, single fixture or group of single fixtures and to similar installations where the fixtures are intended for the use of a family or an individual.
Horizontal Pipe
angle of not more than forty-five (45) degrees with the horizontal plane.
Public Sewer
A common sewer directly controlled by a public authority to which all abutters have equal rights of connections.
Cross-Connection
Any connection or arrangement, physical or otherwise, between a potable water supply system and any plumbing fixture or any tank. receptacle, equipment, or device, through which enables non-potable, used, unclean, polluted, contaminated water or other substances to enter into any part of such potable water system under any condition.

Stack
The vertical main of a system of soil, waste or vent piping extending through one or more stories and extended thru the roof.
Building Sewer
That part of the horizontal piping of a drainage system that starts from the end of the building drain and which receives the discharge of the building drain and conveys it to a public sewer, private sewer, individual sewage disposal system, or other points of disposal.
Fixture Drain
The drainpipe from the trap of a fixture to the junction of that drain with any other drainpipe.

Blank Flange
A blank flange (also called a blind flange) is a solid metal or plastic disc with bolt holes around its perimeter. It has no center bore and is used to seal the ends of pipelines, valves, or pressure vessel openings to stop fluid or gas flow.
A pipe flange that is not drilled for bolt holes.
Alteration
Any change, addition, or modification in construction or occupancy
Loop or Circuit Vent
A vertical vent connection on a horizontal soil or waste pipe branch at a point downstream of the last fixture correction and turning to a horizontal line above the highest overflow level of the highest fixture connected thereat; the terminus connected to the stack vent in the case of loop venting or to the vent stack nearby in the case of circuit venting.
Flush Valve
It is a device located at the bottom of the tank for the purpose of flushing water closet and similar fixtures
Iron Pipe Size
I.P.S
Drain
A pipe, which carries ground and surface waters, storm water, or wastewater into a building drainage system.

Water Main
Also known as Street Main
Gooseneck
This term means the flexible tubing connection between a service pipe and a water main
Quality of Materials
All plumbing fixtures and materials used in any discharge or plumbing system or parts thereof shall be free from defects.

Trap Seal
The maximum vertical depth of liquid that a trap will retain, measured between the crown weir and the top of the dip of the trap.
PRC
Referred to as the "Commission"
Building
A structure built, erected, and framed of component structural parts designed for the housing, shelter, enclosure, or support of persons, animals, or property of any kind.
Surface Water
That portion of rainfall or other precipitation which runs off over the surface of the ground
Privy
The terms privy and latrine both refer to non-flushing toilets or systems for human waste disposal, but they differ slightly in focus: a privy usually emphasizes a small outdoor building or outhouse structure, while a latrine is a broader, more functional term often used for institutional, military, or basic pit-digging setups.
An outhouse or structure used for the deposition of excrement.
Certified Backflow Assembly Tester
A person who has shown competence to test and maintain backflow assemblies to the satisfaction of the Administrative Authority having jurisdiction.

Check Valve
A valve that automatically closes to prevent the flow of liquid or gas in a reverse direction
Contamination
Also, defined as High Hazard