Which is an example of a primary engineering control, PEC?
Laminar airflow workbench
Which is an example of a secondary engineering control, SEC?
Buffer room
Which area should provide ISO Class 5 conditions?
PEC/direct compounding area
As the ISO classification number decreases, the environment generally becomes:
Cleaner
What ISO classification is associated with the buffer room in the course material?
ISO 7
Positive pressure produces net airflow:
Out the room
Why is negative pressure used in hazardous-drug compounding environments?
To help contain hazardous contamination
The direct compounding area is located within the:
PEC
In a cleanroom suite, the PEC is located within the:
Buffer room
Which feature is inappropriate for cleanroom design?
Dust-collecting ledges