1/34
Comprehensive vocabulary flashcards covering basic and advanced mechanical ventilation modes, synchrony graphics, weaning criteria, and clinical capnography principles.
Peak Inspiratory Pressure (PIP)
The maximum pressure measured in the patient's airway at the end of the inspiratory phase during mechanical positive-pressure ventilation.
Plateau Pressure
The pressure measured during an end-inspiratory pause representing alveolar pressure under static, zero-flow conditions; clinically targeted below 30cmH2O.
Positive End-Expiratory Pressure (PEEP)
Mechanical positive pressure maintained in the airway at end-expiration to prevent alveolar collapse, increase functional residual capacity (FRC), and improve oxygenation.
Triggering Variable
The parameter (time, pressure, flow, or volume) sensed by the ventilator that initiates the inspiratory cycle.
Auto-Triggering (Auto-Cycling)
A form of ventilator asynchrony where the ventilator cycles into inspiration without patient effort, commonly caused by water or leaks in the circuit, inappropriate sensitivity settings, cardiac contractions, or external gas sources such as nebulizers.
Double Triggering (Breath Stacking)
Asynchrony that occurs when a patient demands more volume or flow than delivered, resulting in two consecutive ventilator breaths triggered in rapid succession; corrected by increasing VT, increasing peak flow, adjusting inspiratory time (Ti), or switching to pressure support.
Pressure Support (PS)
A patient-triggered, pressure-limited, and flow-cycled mode that provides constant positive pressure during inspiration to reduce the work of breathing (WOB) and overcome endotracheal tube resistance.
Flow Termination (Flow Cycling)
The mechanism terminating inspiration in Pressure Support mode, cycling off when the inspiratory flow decreases to a specific set percentage of peak flow.

Auto-PEEP (Intrinsic PEEP / Air Trapping)
Incomplete exhalation causing alveolar gas trapping and increased end-expiratory pressure, recognized on a flow-time scalar when expiratory flow fails to return to baseline before the next breath begins.

Alveolar Overdistension ("Beaking")
An abnormal change in the inspiratory limb of a dynamic pressure-volume loop appearing as a bird-like beak at high pressures, indicating decreasing lung compliance and excessive tidal volume.
Airway Pressure Release Ventilation (APRV)
A time-triggered, pressure-limited mode that maintains a high CPAP level (Phigh) for lung recruitment across a prolonged duration (Thigh) with brief, intermittent releases to lower pressure (Plow) for carbon dioxide clearance while allowing unrestricted spontaneous breathing.
Pressure Control Inverse Ratio Ventilation (PCIRV)
Pressure-controlled mechanical ventilation utilizing an inspiratory-to-expiratory (I:E) ratio greater than 1:1 (such as 4:1) to improve oxygenation, carrying risks of auto-PEEP and decreased cardiac output.
Independent Lung Ventilation (ILV)
A specialized technique using two synchronized ventilators and a double-lumen endotracheal tube to independently ventilate each lung with tailored tidal volumes and PEEP levels in unilateral lung disease.

Carlens Endotracheal Tube
A specialized double-lumen endotracheal tube designed for independent lung isolation and differential ventilation of the right and left lungs.
Pressure Regulated Volume Control (PRVC)
An adaptive dual-control mode delivering a clinician-set target tidal volume using a decelerating flow pattern while automatically adjusting the inspiratory pressure breath-by-breath based on lung compliance changes.
Permissive Hypercapnia
A lung-protective ventilatory strategy used in acute respiratory distress syndrome (ARDS) where arterial CO2 is intentionally allowed to rise while limiting tidal volumes and pressures, targeting an SaO2 of 85–90%.
High-Frequency Oscillatory Ventilation (HFOV)
A non-conventional ventilatory modality operating at respiratory rates exceeding 60bpm (1Hz=60bpm) delivering sub-deadspace tidal volumes (VT<VD) to provide gas exchange while minimizing cyclic lung stress.
Neurally Adjusted Ventilatory Assist (NAVA)
A mode of mechanical ventilation that monitors the electrical activity of the diaphragm (Edi) using a specialized esophageal catheter to deliver proportional pressure support synchronized in timing and magnitude with the patient's neural respiratory drive.
Electrical Activity of the Diaphragm (Edi)
The microvolt (μV) signal generated by the diaphragm during neural drive to breathe, captured by specialized esophageal sensors in NAVA to trigger and regulate ventilatory assist.
Adaptive Support Ventilation (ASV)
A closed-loop ventilatory mode available on ventilators like the Hamilton Galileo that continuously adjusts respiratory rate and tidal volume based on patient ideal body weight (IBW), lung mechanics, and a target percent of predicted minute volume.
SmartCare
An automated protocol-driven weaning software on the Dräger Evita XL ventilator that monitors patient parameters including VT, respiratory rate, and ETCO2 to titrate pressure support down as tolerated.
Rapid Shallow Breathing Index (RSBI)
A bedside weaning predictor calculated as the ratio of spontaneous respiratory frequency to tidal volume in liters (f/VT); values <60–105breaths/min/L indicate weaning readiness.
Maximal Inspiratory Pressure (PImax / NIF)
A measure of inspiratory muscle strength determined during an occluded inspiratory effort from residual volume; values more negative than −20 to −30cmH2O represent acceptable strength for extubation.
Spontaneous Breathing Trial (SBT)
The diagnostic procedure of placing a patient on minimal or zero ventilatory assistance for 30 to 120minutes to evaluate their readiness for extubation.
Capnography
The continuous, non-invasive measurement and graphic numerical display of carbon dioxide concentration at the patient's airway during the respiratory cycle.
Capnogram
The graphical waveform tracking real-time carbon dioxide concentration plotted against time or expired volume.
Mainstream Capnography
A capnography configuration where the infrared sensor is placed directly in-line at the airway adapter at the endotracheal tube, offering rapid response times without aspiration tubing or water traps.
Sidestream Capnography
A capnography configuration where respiratory gas is continuously aspirated from the airway via small-bore tubing into an internal analyzer chamber located in the monitor.

Capnogram Phases (Phase I - IV)
Phase I (A-B) represents anatomical dead space exhalation; Phase II (B-C) is the rapid rise from mixed alveolar-dead space gas; Phase III (C-D) is the alveolar plateau ending at end-tidal CO2 (D); Phase IV (D-E) is the rapid descending inspiratory phase.
Arterial to End-Tidal CO2 Gradient (PaCO2−PETCO2)
The physiological difference between arterial and end-tidal carbon dioxide, normally measuring 2 to 5mmHg in healthy lungs.
Shunt Perfusion (Low V/Q)
A pulmonary mismatch where alveoli are perfused but unventilated (e.g., atelectasis, pneumonia, mucus plugging), causing the PaCO2−PETCO2 gradient to widen to 4 to 10mmHg.
Alveolar Dead Space (High V/Q)
A pulmonary mismatch characterized by ventilation without adequate capillary perfusion (e.g., pulmonary embolism, shock, cardiac arrest), resulting in a marked drop in ETCO2 and a large arterial-to-end-tidal gradient.
Curare Cleft
A downward notch or indentation appearing in the alveolar plateau (Phase III) of a capnogram indicating spontaneous inspiratory efforts as neuromuscular blocking agents begin to wear off.
Cardiac Oscillations
Small, rhythmic, ripple-like fluctuations visible on the terminal portion of Phase III and Phase IV of a capnogram caused by mechanical heart contractions shifting intrathoracic gas.
Return of Spontaneous Circulation (ROSC)
The clinical re-establishment of a pulse and perfusion during CPR, heralded on a capnogram by an immediate, abrupt rise in ETCO2.