NAME: Powerplant Electrical Power — Grounding and Bonding AC 43.13
NAME: Powerplant Electrical Power — Grounding and Bonding AC 43.13
Front:
What is the maximum allowable resistance for a bonding jumper connection?
A. 0.03 ohm.
B. 0.003 ohm.
C. 0.3 ohm.
Back:
B. 0.003 ohm.
Explanation:
Bonding connections must have very low resistance to allow electricity to flow safely between components.
0.003 ohm (3 milliohms) is the maximum specified for each bonding jumper connection in Section 11-189.
Higher resistance can cause excessive voltage drop, heating, and poor electrical bonding.
What must be done to a surface before installing an electrical bonding connection?
A. Apply paint or anodizing to prevent corrosion.
B. Leave the existing protective finish intact.
C. Remove paint, anodizing, and other nonconductive finishes from the contact area.
Back:
C. Remove paint, anodizing, and other nonconductive finishes from the contact area.
Explanation:
Bonding connections require good electrical contact between conductive surfaces.
Paint and anodizing can act as electrical insulators, increasing resistance.
Removing nonconductive finishes allows a low-resistance connection.
After preparation, aluminum surfaces require appropriate conductive surface treatment, and completed connections need corrosion protection.
How should bonding jumpers be installed on an aircraft?
A. As long as possible to allow flexibility.
B. As short as practicable without interfering with movable aircraft components.
C. Tightly against movable aircraft components.
B. As short as practicable without interfering with movable aircraft components.
Explanation:
Bonding jumpers provide electrical continuity between aircraft components.
Shorter jumpers generally provide lower resistance.
Jumpers must allow normal movement of aircraft components without becoming damaged.
Improper routing can cause chafing, stretching, or interference with flight controls.
Which practice is correct when attaching electrical bonding connections to aircraft structure?
A. Use self-tapping screws to attach bonds through other bonded components.
B. Attach bonds directly to the basic aircraft structure using standard threaded screws or bolts.
C. Attach bonds to any convenient aircraft component using self-tapping screws.
B. Attach bonds directly to the basic aircraft structure using standard threaded screws or bolts.
Explanation:
Bonding connections must provide a secure, reliable electrical path.
Standard threaded screws or bolts of appropriate size provide a secure attachment.
Self-tapping screws are prohibited for bonding purposes.
Bonds should connect directly to the basic aircraft structure rather than relying on other bonded components.
What should be checked when inspecting aircraft electrical bonding connections?
A. Connections are secure, corrosion-free, and use appropriate washers for dissimilar metals.
B. Connections are loose enough to allow movement.
C. Corrosion is acceptable as long as electrical continuity exists.
A. Connections are secure, corrosion-free, and use appropriate washers for dissimilar metals.
Explanation:
Bonding connections must maintain reliable electrical conductivity.
Loose connections can increase resistance and cause intermittent electrical contact.
Corrosion can interfere with conductivity and eventually cause connection failure.
Appropriate washers help protect against corrosion when bonding dissimilar metals, such as aluminum and copper.
What is the proper method of attaching bonding jumpers to tubular aircraft structures?
A. Solder the bonding jumpers directly to the structure.
B. Use suitable clamps with appropriate corrosion protection.
C. Wrap the bonding jumpers around the structure without clamps.
B. Use suitable clamps with appropriate corrosion protection.
Explanation:
Bonding jumpers must be mechanically secure and maintain electrical continuity.
Suitable clamps provide a secure attachment to tubular structures.
Soldering should be avoided when attaching bonding jumpers.
Clamp materials must be selected to minimize corrosion between dissimilar metals.
Which aircraft structural materials must not be used for electrical ground return paths?
A. Aluminum and copper.
B. Stainless steel and brass.
C. Magnesium and carbon fiber composite structures.
C. Magnesium and carbon fiber composite structures.
Explanation:
Ground return paths must safely conduct electrical current without excessive resistance or heating.
Magnesium: Direct electrical ground return connections must not be made to magnesium structure because of the fire hazard.
Carbon fiber composite (CFC): Must not be used as a power return path because its higher electrical resistance can cause localized heating and structural damage.
Why the other answers are incorrect:
A. Aluminum and copper: Both are good electrical conductors. Aluminum alloy jumpers are recommended for most bonding applications, while copper is also widely used.
B. Stainless steel and brass: These materials can be bonded. Copper jumpers are recommended when bonding stainless steel, brass, bronze, copper, or cadmium-plated steel components.
Important distinction: Carbon fiber composite aircraft can still have electrical grounding systems, but power return currents must use suitable alternative conductive paths.
Front:
When bonding jumpers carry substantial ground return current, what must be ensured?
A. The jumper has adequate current-carrying capacity and produces negligible voltage drop.
B. The jumper has high resistance to limit current flow.
C. The jumper is as small as possible regardless of current requirements.
A. The jumper has adequate current-carrying capacity and produces negligible voltage drop.
Explanation:
Bonding jumpers carrying ground return current must safely handle the electrical load.
Adequate current-carrying capacity prevents overheating.
Low resistance minimizes voltage drop.
Undersized jumpers may overheat or fail when carrying excessive current.
The jumper must be selected based on the current it will carry, rather than simply choosing the smallest available wire.
NAME: Powerplant Electrical Power — Clamping AC 43.13
NAME: Powerplant Electrical Power — Clamping AC 43.13
Front:
What is the maximum allowable spacing between clamps supporting aircraft electrical wire bundles?
A. 12 inches.
B. 24 inches.
C. 36 inches.
B. 24 inches.
Explanation:
Wire bundles must be supported by clamps spaced no more than 24 inches apart.
Proper spacing prevents excessive movement, vibration, and chafing.
Additional clamps may be necessary depending on the installation.
Clamps must securely support the wires without damaging their insulation.
How should clamps fit electrical wire bundles compared to RF coaxial cables?
A. Both must be clamped tightly enough to prevent all movement.
B. Wire bundles must not slide through clamps, while RF coaxial cables may slide slightly without being crushed.
C. Both must remain loose enough to slide freely.
B. Wire bundles must not slide through clamps, while RF coaxial cables may slide slightly without being crushed.
Explanation:
Wire bundles: Clamps must hold the bundle snugly so it cannot slide through when a slight axial pull is applied.
RF coaxial cables: Clamps must prevent free movement without crushing or distorting the cable. Slight sliding under a light axial pull is permitted.
Crushing a coaxial cable can distort its cross-sectional shape and interfere with its electrical performance.
Which method is acceptable for supporting electrical wire bundles in aircraft?
A. Adhesive tape can replace clamps if wrapped tightly.
B. Nonmetallic-lined clamps should be used, with cable ties permitted between clamps.
C. Cable ties can completely replace clamps.
B. Nonmetallic-lined clamps should be used, with cable ties permitted between clamps.
Explanation:
Nonmetallic-lined clamps support the bundle while protecting the wires from abrasion and chafing.
Cable ties may be used between clamps but cannot replace adequate clamping.
Adhesive tape deteriorates with age and is not an acceptable substitute for clamps.
According to FAA Figure 11-11, what is the proper mounting angle for electrical cable clamps?
A. Any angle is acceptable if the clamp is tight.
B. The clamp loop should hang below the attachment, within 45° of the downward position.
C. The clamp loop should point upward at a 90° angle.
B. The clamp loop should hang below the attachment, within 45° of the downward position.
Explanation:
The diagram identifies safe clamp orientations within 45° to either side of the downward position.
The attachment hardware should be positioned above the clamp loop whenever practicable.
Improper angles can allow the clamp to rotate under the weight of the wire bundle, potentially causing chafing.

Front:
When must a suitable grommet be installed where a clamped wire bundle passes through a bulkhead opening?
A. Whenever the clearance is less than 1 inch.
B. Whenever the clearance is less than 3/8 inch.
C. Only when the wire bundle touches the bulkhead.
B. Whenever the clearance is less than 3/8 inch.
Explanation:
3/8 inch or greater clearance: Proper clamping can keep the bundle away from the hole edges.
Less than 3/8 inch clearance: A suitable grommet must be installed to protect against abrasion and chafing.
The bundle must remain properly supported by its clamp.

NAME: Powerplant Electrical Power — Worksheet Flashcards
NAME: Powerplant Electrical Power — Worksheet Flashcards
Why do aircraft wire bundles use cord to secure them?
Ties, lacing, and straps are used to secure wire groups or bundles to provide ease of maintenance, inspection, and installation.
Source: AC 43.13-1B, Paragraph 11-158.
What type of lacing cord is used to secure coax cables, and why?
Flat nylon braided waxed lacing tape.
Explanation: Prevents deformation of the soft dielectric insulation, which can cause short circuits or impedance changes.
When installing a new wire installation, what factors determine the wire selection?
Sufficient mechanical strength for service conditions.
Must not exceed allowable voltage drop levels.
Must be protected by system circuit protection devices.
Must meet circuit current-carrying requirements.
Source: AC 43.13-1B, Paragraph 11-66, page 11-21.
Federal Aviation Administration
Why should the length of bonding jumpers be kept to a minimum?
Bonding jumpers should be made as short as practicable and installed so that the resistance of each connection does not exceed 0.003 ohm.
They must not interfere with movable aircraft components or be damaged by their normal movement.
Source: AC 43.13-1B, Paragraph 11-189, page 11-84.
Federal Aviation Administration
What installation precautions apply to bonding jumpers?
Bonding jumpers must not interfere with movable aircraft components, such as flight controls, or be damaged by their normal movement. Connections should be secure and free from corrosion.
Source: AC 43.13-1B, paragraphs 11-188(c–d) and 11-189, pages 11-83–84.
Federal Aviation Administration
Per AC 43.13, what should the resistance of each bonding jumper connection not exceed?
0.003 ohm (3 milliohms).
Source: AC 43.13-1B, Paragraph 11-189, page 11-84.
Federal Aviation Administration
When installing a bonding jumper, how do you ensure a low-resistance connection?
Remove nonconductive finishes, such as paint and anodizing films, from the surface contacted by the bonding terminal.
On aluminum surfaces, apply a suitable conductive chemical surface treatment (chromate conversion coating) within 24 hours of removing the original finish.
Source: AC 43.13-1B, Paragraph 11-189(a), page 11-84.
Federal Aviation Administration
How are bonding jumpers fabricated? List the applicable part numbers and descriptions of materials you would order for the assembly.
I would choose the proper bonding jumper material based on the aircraft materials, then select the correct size, crimp terminals, and compatible hardware to prevent corrosion. Relevant parts include AN735 (clamp), AN960JD10L (washer), and MS25440-5 (washer).
Note: MS25440-5 has not been verified in AC 43.13-1B, so I would not label it as an AC-listed part number.
Should you use solder to attach bonding jumpers? Explain.
No. Solder should be avoided when attaching bonding jumpers.
Source: AC 43.13-1B, Paragraph 11-189(d).
NAME: BOOK
NAME: BOOK
The smallest gauge aluminum wire recommended for use in aircraft systems is _____ gauge.
6 AWG (American Wire Gauge).
No wire bundle should be closer than _____ inches from a control cable.
3 inches.
Explanation: Prevents chafing and interference with moving flight control cables.
Electrical wire bundles are fastened to the aircraft structure with insulated _____ clamps.
Cushion clamps.
Explanation: Secure wire bundles while protecting them from vibration and chafing.
The inside diameter of a conduit must be about _____ percent larger than the maximum diameter of the wire bundle it encloses.
25%.
Explanation: Provides sufficient clearance for the wires inside the conduit.
Give the color code for the insulation on a solderless terminal used on each of the following size wires:
A. 16 gauge
B. 22 gauge
C. 10 gauge
D. 18 gauge
A. 16 gauge = Blue
B. 22 gauge = Red
C. 10 gauge = Yellow
D. 18 gauge = Red
Explanation: Terminal insulation colors identify the wire-size range the terminal is designed to accept.
There should never be more than _____ terminals on any one stud.
4 terminals.
Explanation: Limiting the number of terminals helps maintain secure electrical connections.
NAME: Powerplant Electrical Power — Additional Flashcards (50–55)
NAME: Powerplant Electrical Power — Additional Flashcards (50–55)
What determines the correct torque specification for aircraft hardware?
Torque is determined by the shank diameter, thread count, and material. Hex-head size determines only the wrench size, not the hardware size.
What procedures should be followed when torquing aircraft hardware?
Use a calibrated torque wrench, apply smooth controlled force, reach the specified torque while in motion, and account for drag torque.
Never overtorque hardware to align safety holes.
What type of hardware is AC 43.13-1B, Table 7-1, used for?
Oil-free, cadmium-plated steel nuts and bolts, such as AN310 and AN320 nuts.
The table should not be used for hardware made from other materials.
What are the requirements for lacing and securing aircraft wire bundles? (List 4)
Single-cord lacing: Bundles 1 inch in diameter or less.
Double-cord lacing: Bundles 1 inch or larger.
Bundle ties: Where wire supports are more than 12 inches apart.
Clamping: Secure wire bundles every 24 inches or less.
What is electrical shielding, and what is its purpose in aircraft wiring?
Shielding is an outer metal covering over a wire or component that prevents electromagnetic interference (EMI) from entering or leaving the wire and directs the interference to ground.
Why must the correct type of RTV silicone sealant be used on aircraft?
Some RTV silicone sealants release acetic acid during curing, which can cause corrosion.
Only the correct aircraft-approved grade should be used.
What is T-1223 Koro Seal lacing, and why is it preferred over cable ties?
T-1223 Koro Seal is a 5/32 × 3/32-inch oval vinyl cord used to tie and bundle aircraft electrical wires and cables.
It is preferred because it leaves no sharp edges in the finished product.
When should manufacturer torque specifications be used instead of standard torque tables?
Always use the manufacturer's specified torque value and procedure when provided. Use standard torque tables only when a specific torque value is not given.
What types of lacing cord or tape are used to secure aircraft electrical wires?
Braided lacing tape (A-A-52080): Used for tying and lacing wire bundles.
T-1223 Koro Seal: Oval vinyl cord used for securing wires and cables without leaving sharp edges.
Note: Single-cord and double-cord lacing are installation methods, not separate materials.
NAME: Section 12C — Additional Flashcards
NAME: Section 12C — Additional Flashcards
Avionics equipment _____ (is or is not) easily damaged by heat.
Is. Excessive heat can damage sensitive electronic components.
Avionics equipment should be turned off during engine starting and shutdown to prevent damage from _____ currents and voltage _____.
Surge currents and voltage spikes.
Aircraft switches must be of the - type.
Snap-action.
Aircraft circuit breakers must be of the - type.
Trip-free.
Explanation: The breaker will trip and remain open during a fault, regardless of the operating control position.
Static _____, also called static _____, are usually located on the _____ edges of primary control surfaces and discharge static electricity to the _____.
Static dischargers, also called static wicks, are located on the trailing edges and discharge static electricity into the atmosphere.
What type of antenna cable consists of a center conductor surrounded by a dielectric, an outer conductor or shield, and protective insulation?
Coaxial cable.
When should aircraft antenna cables be replaced?
When they are dented, kinked, distorted, crushed, or have exposed wire braid.
NAME: Summary Checklist — Additional Flashcards
NAME: Summary Checklist — Additional Flashcards
What should aircraft electronic equipment be kept free of?
Dust, foreign material, corrosion, and oxidation.
What type of cable carries radio frequency (RF) signals between aircraft radios and their antennas?
Coaxial cable.
How far should the ground plane extend around a VHF communications antenna?
24 inches outward in all directions.
The general rule is a distance equal to the antenna's height.
What are the minimum separation distances between aircraft communications antennas?
VHF to VHF: 5 feet
ELT to VHF: 5 feet
DME to transponder: 2 feet
Where are glideslope antennas typically installed on large aircraft, and why?
In the nose radome, because glideslope signals are received from the front of the aircraft.
Why must ADF antennas be installed and calibrated correctly?
ADF antennas are highly directional and require proper installation and calibration to provide accurate navigation information.
What precautions apply when installing WAAS and GPS antennas?
They are sensitive to active antennas and must be installed in precise locations according to the manufacturer's instructions.
What is the purpose of an avionics master switch?
It allows avionics to be turned on and off separately, protecting them from electrical surges and spikes during engine startup and shutdown.
NAME: Powerplant Electrical Power — Additional Flashcards (74–82)
NAME: Powerplant Electrical Power — Additional Flashcards (74–82)
How should aircraft wiring be routed to prevent electromagnetic interference (EMI)?
Antenna leads should be routed away from equipment that produces electromagnetic interference, such as inverters, strobe lights, and ignition components.
Explanation: EMI can interfere with radio communication and navigation signals.
Example: Routing a VHF antenna cable too close to an engine ignition system may introduce noise into radio communications.
How can you determine if an AN/MS electrical connector is fully engaged?
AN/MS electrical connectors generally have a visual indication of full engagement.
Explanation: This helps confirm the connector is properly secured, preventing accidental disconnection or intermittent electrical contact.
Example: After connecting an AN/MS connector, a mechanic checks its engagement indicator to verify the connection is secure.
How are coaxial connector pins attached to wires, and how does this differ from standard AN/MS electrical connectors?
Coaxial connector pins: May be crimped or soldered.
Standard AN/MS connector pins: Are typically crimped.
Explanation: The attachment method depends on the connector design and manufacturer's instructions.
Example: A coaxial antenna connector may require a soldered center pin, while a standard MS electrical connector uses a crimped contact.
What is the difference between grounding and bonding in aircraft electrical systems?
Grounding: Electrically connects a conductive object to the aircraft's primary structure.
Bonding: Creates a low-impedance electrical connection between two or more conductive objects.
Explanation: Grounding can provide a current return path and prevent radio-frequency potentials. Bonding helps equalize electrical potential and reduce interference.
Example: A bonding jumper connects two metal components, while a grounding connection connects electrical equipment to the airframe.
What do the numbers in PRC sealant designations indicate, and how do PR1422 A-1/2 and A-2 differ?
The numbers indicate the maximum application time.
PR1422 A-1/2: 30 minutes.
PR1422 A-2: 2 hours.
Explanation: The A-2 has a longer application time but takes approximately twice as long to fully cure (48 hours, according to the class PowerPoint).
Example: A mechanic needing more time to apply sealant may select PR1422 A-2 rather than A-1/2, when suitable for the application.
What are the common types of electrical circuit faults in aircraft, and which is the most common?
Open circuit: Broken or interrupted electrical path. Most common fault.
High resistance: Often caused by corrosion at connections.
Bypass or short: Can result from damaged wire insulation.
Short to ground: Should cause the circuit protection device to open.
Example: A broken wire causes an open circuit, preventing a landing light from operating.
What is the difference between dry and wet torque conditions, and which specifications should be followed for aircraft electrical connections?
Dry torque: Torque applied to clean, unlubricated threads.
Wet torque: Torque applied to threads with lubricant or an approved compound.
Explanation: Thread lubrication changes friction and the clamping force produced by a given torque. Follow the applicable manufacturer's specifications and installation requirements.
The class PowerPoint references SAE ARP1928 for electrical connection torque, but does not specify when to apply that standard.
Example: A mechanic must determine whether the specified torque assumes dry or lubricated
How is T-1223 Koro Seal lacing used to secure aircraft electrical wires?
Stretch and wrap the Koro Seal three times around both lines.
Route the loose ends through the middle of both lines and the wrapped Koro Seal.
Pull the ends tight to form a knot.
Finish with a square knot.
Explanation: This secures the wires together without leaving sharp edges that could damage nearby wiring.
Example: A mechanic uses Koro Seal to secure two electrical wires together during installation.
Why must sufficient slack be provided at electrical wire termination points?
Enough slack must be provided to allow movement of shock-mounted equipment without damaging the wires or electrical connections.
Explanation: Shock mounts allow equipment to move slightly during vibration. Insufficient slack can place tension on terminals and cause wire damage.
Example: Wiring connected to a shock-mounted instrument needs enough slack to accommodate movement without pulling on its connector.
What determines aircraft hardware size and torque, and what does the hex-head size determine?
Shank diameter and thread count: Determine hardware size.
Hex-head size: Determines the wrench size, not the hardware size.
Torque specification: Depends on hardware size, material, and applicable manufacturer requirements.
Example: A 1/4-inch bolt may use a 7/16-inch wrench, but its hardware size remains 1/4 inch.
What is the proper technique for tightening aircraft hardware with a torque wrench?
Use a calibrated torque wrench.
Apply smooth, controlled force.
Pull the wrench toward your body for better control.
Reach the specified torque while the fastener is moving.
Account for drag torque.
Never overtorque to align safety holes.
Example: When tightening a nut, pull the wrench smoothly toward yourself until the specified torque is reached.
What instrument is used to measure bonding resistance in aircraft, and what is the maximum allowable resistance?
An M1 milliohm meter or similar instrument is used to measure bonding resistance.
Maximum resistance: 0.003 ohm (3 milliohms).
Purpose: Verify that electrical bonding connections have sufficiently low resistance.
Explanation: A milliohm meter measures very small electrical resistances that ordinary multimeters may not measure accurately.
Example: A bonding jumper measures 0.002 ohm (2 milliohms), which is within the 0.003-ohm limit.