home automation and HMI

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/25

flashcard set

Earn XP

Description and Tags

Vocabulary flashcards covering core definitions, operating modes, design configurations, PLC I/O mappings, and ladder logic rules for Human Machine Interfaces (HMIs).

26 Terms

1
New cards

Human Machine Interface (HMI)

Any interface that permits interaction between a human and a machine in order to control or monitor a process.

2
New cards

Operator Machine Interface (OMI)

An alternative industry term for a Human Machine Interface (HMI).

3
New cards

Man Machine Interface (MMI)

An alternative industry term for a Human Machine Interface (HMI).

4
New cards

Role of HMI

To provide interpretation of raw PLC data and add value, converting simple numerical data (such as Output Y01 ON) into meaningful information (such as 'The discharge pump is running').

5
New cards

Design / Configuration Mode

An operational mode of an HMI that allows the user to create and design display screens.

6
New cards

Runtime Mode

An operational mode of an HMI that displays the screens and populates them with real-time operational information.

7
New cards

Static Objects

HMI application objects that form the screen background or provide fixed data displays.

8
New cards

Dynamic Objects

HMI application objects that can be animated to present changing process data.

9
New cards

HMI Runtime Tasks

The three sequential operations executed in runtime mode: 1. Get data from the PLC (via driver/protocol/cable); 2. Store data in the HMI internal storage area; 3. Use data to update screen dynamic fields.

10
New cards

PLC Analogue Devices

PLC devices such as timers and counters whose data values can be numbers other than 0 and 1.

11
New cards

PLC Digital Devices

Binary PLC devices (such as inputs and outputs) whose data values are strictly 0 or 1.

12
New cards

Affordance

A technical term used to describe the way in which an object's appearance suggests its intended purpose (e.g., a box/border drawn around changing dynamic text to reinforce that it needs to be monitored).

13
New cards

Touch Key

A defined field on an HMI screen that reacts to an operator action, such as executing a momentary command to set a tag.

14
New cards

Start Conditions Rule

The ladder programming rule specifying that all start conditions (e.g., physical push button X3, contactor run feedback X10, and HMI start tag M10) must be placed in parallel.

15
New cards

Stop Conditions Rule

The ladder programming rule specifying that all stop conditions (e.g., physical stop button X2 and HMI stop tag M11) must be placed in series.

16
New cards

Tag M10

An HMI I/O tag assigned to a momentary touch field labeled START to trigger conveyor start via ladder logic.

17
New cards

Tag M11

An HMI I/O tag assigned to a momentary touch field labeled STOP to trigger conveyor stop via ladder logic.

18
New cards

Input X0

PLC input connected to the auxiliary O/L RELAY; indicates Inactive when OFF and OVERLOAD when ON.

19
New cards

Input X1

PLC input connected to the auxiliary EMERGENCY STOP; indicates Inactive when OFF and E-STOP when ON.

20
New cards

Input X2

PLC input connected to the STOP PB (normally closed); indicates STOP when OFF and Inactive when ON.

21
New cards

Input X3

PLC input connected to the START COUNTER RESET / Start PB (normally open); indicates Inactive when OFF and START when ON.

22
New cards

Input X10

PLC input providing MOTOR RUN FB (feedback); indicates STOPPED when OFF and RUNNING when ON.

23
New cards

Output Y2

PLC output connected to the MOTOR CONTACTOR (Cont KM1); indicates STOP when OFF and RUN when ON.

24
New cards

Output Y4

PLC output connected to the EJECT SOLENOID; states are RETRACT / 'retracted' when OFF and EXTEND / 'extended' when ON.

25
New cards

Counter C0

The PLC counter signal linked to the dynamic Analogue Numeric field on the HMI to display the reject product count (configured with 3 or more positions and 0 decimals).

26
New cards

E1043