1/42
How to set up Apera vue system, Robot Communication, and work cell layout
What is the first thing you should do when at the Apera Vue Pc
Open setup > camera > Camera settings and set the IP address and mask to the appropriate values that match network settings.
where do you go to see the ip address for the cameras on the Apera pc
Settings > Network > you will see three active connection, two are the cameras the one is the PC
what numbers can you change in the camera ip address if the ip is 192.168.1.20 with a 255.255.255.0 subnet mask
the number in the fourth section(20)
what numbers can you change in the camera ip address if the ip is 192.168.2.20 with a 255.255.0.0 subnet mask
the third and fourth section ( 2 and 20 )
how would you check the computer connection to the robot?
go to the terminal on the apera pc and type ping 192.168.1.20 ( robot ip) and see if all sent messages are received by the robot.
how do you stop the terminal on the computer from pinging the robot or running a command in general?
CTRL + C
where do you set the cameras to be a stereo pair on the apera pc?
setup > cameras > camera groups > Add and a stereo pair and select the two camera s you are configuring.
you have two cameras set up on the apera pc. one camera is giving you an image but the other one is black. what could the issue be?
check the Ip address in the network settings on the PC making sure the Ip and subnet mask match in apera vue, if they do match then check cable connections it would most likely be a bad cable.
when setting up the camera groups for the stereo pair what would be the max ethernet throughput be?
1.0Gbps
what would happen if the max ethernet throughput isn’t set correctly?
the camera pair would not give you a image
what is the difference between fixed frame and eye to hand mount types?
A fixed frame mount type is when the camera is mounted to a fixed position like a fixture in a workcell. A eye to hand mount type is when the camera is mounted to the robot Eoat.
where do you find the Calibration file for the camera.
either on the USB that came with the camera or go to computer
what type of calibration do you use for a pre-calibrated camera?
in field calibration
where do you mount the Procal Board when running calibration for a eye in hand application?
either on a fixture or on the floor
where do you mount the Procal Board when running calibration for a fixed frame application?
on the EOAT on the robot
what is a PROCal Board
a board with patterns used to calibrate a apera vue camera position and robot joint positions.
why do we need to perform a in field or full camera calibration?
to set the cameras position in space
why do we need to run robot calibration?
so the 3D pose from the Aperas camera coordinate system can be converted to a robots coordinate system.
you are given a “Flat” scene why is it flat / lacks depth
the search minimum and maximum are outside the working distance of the camera
VuePoet XS working Distance
357 - 1948 mm
VuePort S working Distance
844 - 1483 mm
VuePort M working distance
996 - 1977 mm
VuePort M+ working distance
1201 - 3201 mm
VuePort L working Distance
1340 - 3941 mm
VuePort LT working distance
2375 - 4850 mm
what Vue Port Camera is only used on EOAT? Vueport M, VuePort L+, Vue Port W+, Vueport XS
VuePort XS
what program do you run to calibrate robot on apera ( fanuc robot)
Apera hand eye calibration with miscal
when setting up the pick point automatically in your pipe line what must you do before you select find part in vision region
move to the capture position and run set up capture.
when setting up the pick point automatically in your pipe line what must you do before you set primary pick pose
move to the pick position and run set up capture
after setting your pick point what do you need to finish before you move on to setting your deviations?
set reference pose under the advance tab
once your done making you pipelie you need to?
restart apera vue
what type of application is a eye in hand camera set up used for
Derack
what type of scene do derack applications use?
Search region
where do you go to set Apera Ip Address on Fanuc robot TP
Host comms > TCP/IP > select first unused numbered row
where do you go to set client
Host Comms > Tcp/Ip > show > Clients
what ip address do you put in your server ip/host name for your client
Apera PC
what do you put under remote port for you client
14040
what do you set the protocol to under your client
SM
where do you configure the system variables on Robot TP
menu > next > system > variables >$hostc_CFG > detail
what Number row should you select under $Hostc_CFG
the number row that correspond with the client you previously configured
in the system variables what do you set the $server_Port to
14040
how do you start the server on the Robot TP
Setup > next > host Comm > TCP/IP > show > Clients > highlight your client then select action > define > action > start
what string register do you use to set your camera pair id
SR 22