Streptococcus aureus
cluster-forming, catalase-positive staphylococcus must not be confused with chain-forming, catalasenegative streptococci; the distinction directs confirmatory testing and clinical interpretation.
Kingdom Protista
Modern classification reflects rRNA-based evolutionary relationships and prevents cyanobacteria, fungi, and protozoa from being treated as one uniform group
Blue-green algae
They lack a membrane-bound nucleus and chloroplasts; harmful cyanobacterial blooms can produce clinically important toxins.
Higher bacteria such as Actinomycetales
Branching bacterial forms can resemble fungal hyphae. Gram stain and modified acid-fast methods help distinguish clinically important genera
Observe bacteria under HPO
Most bacteria are near the resolving limit of brightfield microscopy; species identification cannot be made reliably from unstained morphology alone
Prepared slides using Google
Digital images do not teach specimen scanning, depth-of-field control, artifact recognition, or biosafety
compound light microscope
foundational diagnostic instrument because many infectious agents, host cells, crystals, and tissue changes are too small to evaluate with the unaided eye. In clinical microbiology, microscopy can rapidly provide a presumptive answer before culture or molecular testing is complete
Gram-stained cerebrospinal fluid
showing intracellular gram-negative diplococci, for example, can trigger urgent clinical action.
Moves to left
slide is moved to the right
Image is seem observer
if the slide is pushed away
Magnification
How many times larger the image appears than the object.
Necessary for visibility, but not proof of added detail or accurate identification.
Resolution
Ability to distinguish two close points as separate.
Determines whether adjacent cocci, nuclear details, cilia, hyphae, or intracellular organisms can be separated.
Contrast
Difference in brightness or color between the specimen and background.
Improved by stains, condenser/iris adjustment, phase contrast, fluorescence, or dark-field optics.
Numerical aperture
Light-gathering ability of an objective/condenser; increases with refractive index and acceptance angle.
Higher numerical aperture improves resolution.
Correct condenser position and immersion oil are therefore functional, not cosmetic.
Refractive index
Extent to which a medium bends light.
Oil approximates the refractive index of glass, reducing refraction and allowing more light into the 100x objective.
Depth of field
Thickness of specimen that remains acceptably focused at one setting.
Decreases as magnification/NA increase. Fine focusing through planes reveals layered structures and prevents missed organisms.
Field of view
Diameter of the circular area visible.
Decreases as objective magnification increases; systematic scanning at low power prevents sampling error.
d = 0.61λ/NA
classical relationship for lateral resolution
d
minimum resolvable distance
λ
wavelength of light
NA
numerical aperture. Shorter
wavelengths and higher numerical aperture improve resolution
bright-field light microscopy
generally resolves structures on the order of about 0.2 micrometers under optimal conditions.
Bacteria, Archaea, and Eukarya.
three domains and cellular organization
Bacteria
nucleus Absent
one main circular chromosome
70S cytoplasmic
Often peptidoglycan; absent in some bacteria
Ester-linked fatty acids
Most recognized bacterialpathogens
Small cells often require staining and oil immersion
Archaea

Eukarya

Mitochondria and chloroplasts
appear on the bacterial side of the tree because endosymbiotic theory proposes that ancestral bacteria were incorporated into early eukaryotic cells.
Bacterial cells
lack a membrane-bound nucleus
Eukaryotes
more structurally complex
Protozoa
may show nuclei, motility organelles, food vacuoles,
Fungi
form yeasts, pseudohyphae, or true hyphae and reproductive structures.
Algae
possess chloroplasts and pigments, although medically important microalgae may be recognized because of toxin production rather than tissue
invasion.
Base and arm

Head or body tube

Revolving nosepiece

Stage and mechanical stage

Coarse-focus knob

Fine-focus knob

Rack stop

Interpupillary and diopter controls

Mechanical parts

OBJECTIVE LENSES

Ocular or eyepiece

Scanning objective

Low-power objective

High-dry objective

Oil-immersion objective

Illuminating parts
Lamp or mirror
Condenser
Iris diaphragm
Field diaphragm
Brightness control
Lamp or mirror

Condenser

Iris diaphragm

Field diaphragm

Brightness control

Use oil if indicated

Biosafety
part of microscopy
Bacillus subtilis

Pseudomonas aeruginosa

Staphylococcus aureus

Streptococcus species

Actinomycete correlation

Bacteria
Bacillus subtilis
Pseudomonas aeruginosa
Staphylococcus aureus
Streptococcus species
Actinomycete correlation
Protozoa
Entamoeba histolytica
Balantioides coli formerly Balantidium coli
Trichomonas vaginalis
Amoeba proteus
Paramecium
Entamoeba histolytica

Balantioides coli formerly Balantidium coli

Trichomonas vaginalis

Amoeba proteus

Paramecium

Algae and related aquatic microorganisms
Diatoms
Chlamydomonas
Dinoflagellates
Spirogyra
Cyanobacteria
Cyanobacteria

Spirogyra

Dinoflagellates

Chlamydomonas

Diatoms

Fungi
Aspergillus niger
Penicillium species
Rhizopus stolonifer
Aspergillus versus Mucorales
Aspergillus versus Mucorales

Rhizopus stolonifer

Penicillium species

Aspergillus niger

Bacillus subtilis

Staphylococcus species

Streptococcus species

Amoeba proteus

Paramecium

Spirogyra

Parfocal
object that is focused with one objective remains approximately focused after another objective is rotated into place.
improves speed and reduces the chance of losing a sparse organism
Working distance
between the front lens of the objective and the specimen when the image is in focus
decreases as magnification and numerical aperture increase.
short working distance at 40x and especially 100x explains why coarse focus should not be used at high power.
Field of view
diameter of the circular area visible through the microscope
divided by objective magnification gives an approximation when the system is compatible.
Micrometer
micrometre or micrometer
symbol µm
equals 10^-6 meter
unit or a measuring device
18 mm
ocular has field number
naked eye
specimen appears smaller, upright, and only gross features are visible
Under the low-power objective
The image is enlarged, inverted and reversed, and shows detail that
cannot be resolved unaided.
Scanning

Low power OBJECTIVE

High dry

Oil immersion

Field diameter
is approximately inversely proportional to objective magnification
Moving from 10x to 40x reduces field diameter to roughly one fourth and field area to roughly one sixteenth, assuming the same ocular
Moving from 10x to 100x reduces field diameter to about one tenth and field area to about one hundredth.
Dark-field MICROSCOPY

Phase-contrast MICROSCOPE

Differential interference contrast

Fluorescence MICROSCOPE