1/25
Vocabulary flashcards covering x-ray interactions with matter, attenuation concepts, interaction energy thresholds, mathematical relationships, and contrast effects.

Attenuation
The reduction in the number of x-ray photons in the beam as a result of photons interacting with matter and giving up their energy.
Low Energy Photon Interaction Location
Low energy photons interact with the whole atom.
Moderate Energy Photon Interaction Location
Moderate energy photons interact with orbital electrons.
High Energy Photon Interaction Location
High energy photons interact with the nucleus of an atom.
Five Basic Interactions Between X-rays and Matter
Coherent scattering, Photoelectric (PE) absorption, Compton scattering, Pair production, and Photodisintegration.
Photoelectric Absorption
An interaction where an incident photon's energy is completely absorbed by an inner-shell electron, ejecting the electron as a photoelectron and creating an inner-shell vacancy.
Photoelectron Energy Equation
Ei=Eb+Eke, where Ei is the energy of the incident photon, Eb is the binding energy of the electron, and Eke is the kinetic energy of the photoelectron.
Photoelectron Characteristics
Possesses kinetic energy (Eke) and mass, and is reabsorbed quickly within 1–2mm of tissue.
Characteristic Cascade
The process where an inner-shell vacancy in an ionized atom is filled by an outer-shell electron, which undergoes a change in energy level and emits a characteristic photon.
Secondary Radiation
Radiation that originates from irradiated material outside of the x-ray tube, such as characteristic photons emitted from patient tissue after photoelectric absorption.
Photoelectric Absorption Condition #1
The incident photon energy (Ei) must be greater than or equal to the binding energy (Eb) of the inner-shell electron (Ei≥Eb).
Photoelectric Absorption Condition #2
PE interaction is more likely if incident photon energy (Ei) and inner-shell electron binding energy (Eb) are close to each other, decreasing dramatically as photon energy increases according to an inverse cubed relationship (E31).
Photoelectric Absorption Condition #3
PE absorption is more likely to occur in elements with a higher atomic number (Z#), possessing a direct cubed relationship (Z3) where doubling the Z# increases the chance of PE absorption by a factor of 8.

Coherent Scatter
A non-ionizing interaction involving low energy photons (below 10keV) where electrons vibrate at photon frequency without being ejected, causing the atom to release a photon equal in energy to the incident photon in a different direction.
Thompson Scatter
A type of coherent scatter that involves interaction with a single outer-shell electron.
Rayleigh Scatter
A type of coherent scatter that involves interaction with all electrons of the atom.

Compton Scatter
An interaction where an incident photon (Ei) interacts with a loosely bound outer-shell electron, ejecting it as a recoil electron and continuing in a different direction as a scattered photon with reduced energy.
Compton Scatter Energy Equation
Ei=Es+Eb+Eke, where incident photon energy (Ei) is distributed between scattered photon energy (Es), binding energy (Eb), and recoil electron kinetic energy (Eke).

Compton Scattering Angle Effects
Diagram illustrating how photon energy (ranging from 0.05MeV to 2.0MeV) influences the angle of scattering and energy distribution.
Recoil Electron (Compton Electron)
The outer-shell electron ejected during a Compton interaction that travels until it fills a vacancy in another atom.

Pair Production
An interaction requiring incident photon energies of 1.02MeV or higher where the photon energy is absorbed by the nucleus, making it unstable and causing it to release an electron pair (a positron and a negatron).
Annihilation Reaction
An event in pair production where an unstable positron combines with a nearby electron, converting their mass into two 0.511MeV photons traveling at 180∘ to each other.
Photodisintegration
An interaction occurring at extremely high energies (10MeV or greater) where photon absorption by the nucleus causes the excited nucleus to release an alpha particle.
Technical Factor Selection: Increasing kVp
Increases overall photon transmission through tissue without interaction, while within the attenuated beam, it decreases PE absorption and increases the relative percentage of Compton scatter.
Short Scale Contrast Conditions
Image contrast produced when PE absorption interactions predominate, associated with low kVp/high mAs, lower energy ranges (25–45keV produced by 40–70kVp), and high Z# materials or contrast agents.
Long Scale Contrast Conditions
Image contrast produced when Compton interactions predominate in the diagnostic energy range, associated with high kVp and low mAs.