1/101
Looks like no tags are added yet.
what is a common residential amperage
200 a
what is a common commercial amperage
400 a +
lock out/ tag out
a safety procedure to ensure equipment are shut off and connect restart while workers perform maintenence
what is the purpose of LOGO
prevent people from getting in there and becoming injured
mutual inductance
the effect of one coil inducing a voltage in another coil
transformer (xmfr)
an electrical device that uses electromagnetism to change voltage from one level to another or to isolate one voltage to another
what is the general purpose of xmfr’s
to step UP or step DOWN voltage
what principles do xmfr’s use to operate?
electromagnetic mutual inductance
pole mounted xmfr - purpose ?
used for powerlines running overhead
overhead distribution
pole mounted xmfr - typical locations
rural areas and older neighborhoods
pole mounted xmfr - pros & cons
pro - low installation cost
con - harder maintenance
pad mounted xmfr - purpose
used when powerlines are underground
underground distribution
pad mounted xmfr - typical locations
commercial, campuses, and new residential developments
pad mounted xmfr - pros
pro - cleaner appearance, safety, and reliable
overhead power lines
electrical conductors suspended above ground using utility poles or transmission towers to transport electrical power over short/long distances
overhead primary (oh1)
carry high-voltage medium electricity
overhead secondary (oh2)
delivered stepped down low-voltage
how can you tell the difference between electrical lines vs. telephone lines?
electrical lines are almost always at the highest point
weather head / service head
a waterproof service point where overhead service drop conductors enter the service entrance riser pipe going to the meter socket
weather head - purpose
protect overhead from weather
weather heads - typical locations
near the power meters, lower to the ground
single phase power
uses one alternating current (ac) waveform
it periodically drop to 0V every cycle, creating a pulsating torque
single phase - typ. locations
residential and light commerical (phases)
which voltage is typically used for general receptacles and lighting
1P-120V
which voltage is typically used for heating, cooling, and cooking
1P-240V
three phase power
a combination of 3 alternating voltage waveforms, each displaced 120 electrical degrees apart
3 overlapping waves that never drop to 0 simultaneously delivering continuous flow of power
three phase - typ. locations
industrial factories, data centers, hospitals, large commercial, and heavy duty machinery
voltage (volts/v/E)
the amount of electrical pressure in a circuit
how is voltage produced
by electromagnetism (generators)
compared to water, voltage is similar to ?
water pressure
amperage (amperes/amps/I)
measures the flow rate of electric current
compared to water, amps are similar to ?
water flow
power (watts/w/P)
volts (v) x amps (a)
what is the unit of measure for power
watts (w) / kilo-watts (kw) / million-watts (mw)
volt-amps (va)
disconnect switch
a mechanical safety device used to completely de-energize an electrical circuit or equipment for service, maintenance, or emergency shutoff
disconnect switch - simple terms
turn power on/off
equipment rating
the max voltage the switch can safely handle (in volts alternating current / vac)
conduits
a metallic tube that protects and routes electrical wiring
conduits - simple def.
wires runing thru metallic tubes
tugger / cable puller
a mechanical tool used to pull wires and heavy feeder cables thru conduits
name common conduit materials
pvc
emt
imc, rmc, fmc
romex (plastic)
metal clad
polyvinyl chloride (pvc) conduits
strong, lightweight plastic pipe used for underground, indoor, and outdoor installation
pvc - typ. locations
underground
pvc - pros
cheap labor & cost > easy to cut
rust / corrosion resistant
high impact resistance & tensile strength
pvc - sizing
sch 40 & 80
electric metallic tubing (emt)
light gauge metallic tubing used to route wires
emt - typ. locations
commerical apps, indoors, retail spaces
emt - pros & cons
pros - easy to cut, lightweight, inexpensive, easy to bend
cons - galvanized (aka not good underground or in wet/corrosive areas
emt - connections
compression fittings
set-screw
what is another name used for emt
thin-wall conduit
intermediate & rigid metal conduit (imc, rmc)
a heavy-duty galv. steel tubing designed to protect and route electrical wiring
how does imc compare to rmc and pvc
33% lighter & thinner than rmc
stronger than emt
imc, rmc - pros & cons
pros - strong, corrosion-resistant interior
cons - not good underground
imc, rmc - connections
threaded couplings / fittings
imc, rmc - typ. locations
areas prone to physical dmg.
parking garages
how does rmc compare to imc and emt
heaviest & thickest wall (most durable)
conduit body
a tubular junction fitting with a removable cover that connects sections of electrical conduit
conduit body - purpose
gives electricians access to the interior of a raceway to pull, splice, inspect, and redirect wires
conduit body - type lb
a conduit body that features a back exit for an immediate 90 deg. turn through a wall (pull point + change in direction)
junction box (j-box)
a protective enclosure that houses/secures electrical wires
jbox - purpose
used to join, splice, tap, or terminate conductors
focuses on wire connections
pull box
an enclosure installed in a raceway system to assist with pulling conductors through conduit runs
pull box - purpose
reduce difficulty when pulling wires thru long runs or runs w/ multiple bends
focuses on wires pulling and passing through
does NOT deal with splices
gutters
an elongated enclosure used to contain, distribute, and organize conductors over a distance
gutters - purpose
serve as a wiring distribution channel
focuses on conductor distribution
aka “trough” or “wire way”
nec - 360 degree bend rule
limits the total sum of all bends a single continuous conduit can make between pull points to a max of 360
inline (direct) meter
measures current flowing directly through meter
why would an inline meter be pref.
simple installation & low cost
inline meter - typ. location
residential & small commericial (metering)
inline meter - range
low to medium currents ~ 5a-100a
current transformer (ct) meters
measures current indirectly through external current transformers (ct)
how does a ct meter work
the ct reduces the primary current to a standardized secondary current. there is a ct ratio
ct meter - cons
complex installation & high cost
ct meter - typ. locations
large commerical & industrial
ct meter - range
high current apps ~ 5a-6000a
service panel
an electrical box designed to contain fuses or circuit breakers for protecting the individual circuits of a bldg. from the distribution system
what are other names for the service panel?
breaker box, load center, or main panel
service panel - components
main breaker, bus bars, circuit breakers, dead front, lugs
service panel - typ. locations
electrical rooms, utility rooms, or in basements
service panel - purpose
receives incoming power from the utility company and divides it into individual circuits throughout a bldg.
subpanel
a panel supplied by the main service panel and distributes circuits to a specific area of the bldg
how does the relationship between service panels and subpanels work?
the service panel must have a circuit breaker large enough to meet the demands of the subpanel
subpanel - components
branch circuit breakers, feeder wires, neutral & ground bars
subpanel - typ. locations
near the areas they serve or they may extend to a seperate bldg
subpanel - purpose
divide and manage the power loads more efficiently
prevent overloading the main panel
generator
an electromechanical device that converts mechanical energy into electrical energy by means of electromagnetism induction
part of emergency power family
a generator must have what?
the same voltage output and # of phases as the regular bldg. supply system
how are generators powered?
diesel, gasoline, natural gas, or propane
diesel generators - pros & cons
pros - best for large power requirements, lower maintenance cost, long operating life
cons - high installation & operating cost
what is the start up time for a diesel generator?
10 seconds
name the 3 types of generators mentioned
portable
mobile
stationary
portable generator
a hand-carries generator that can easily be moved from location to location
mobile generator
a vehicle mounted generator that is moved on wheels or rollers
stationary generator
a generator that is permanently installed as part of a standby or emergency backup power system
how are generators chosen?
based on voltage output of the regular bldg supply system and the amount of load required to supply
automatic transfer switch (ats)
a device that switches a load between two diff. sources of electrical power (ac -> dc)
how does an ats work
continuously monitors utility power for fluctuations or outages
power failure is detected
triggers a generator to start up (utility power → generator power)
uninterruptable power supply (ups)
an electrical storage device that provides stable and reliable power during fluctuations or failures of the primary power source
ups - purpose
used to maintain the operation of critical loads during short interruptions in the primary power source
how does ups work during normal operating hours
utility power supplies the ups to charge it like a battery pack