Identify two medical devices commonly found in each of the following hospital areas: Intensive Care Unit (ICU), Obstetrics and Gynaecology (O&G) Ward, and Imaging Department.
Intensive Care Unit (ICU): Mechanical ventilator, multi-parameter patient monitor (or infusion pump, defibrillator). 2. Obstetrics and Gynaecology (O&G) Ward: Cardiotocograph (CTG), fetal Doppler (or infant incubator). 3. Imaging Department: X-ray machine, ultrasound machine (or CT scanner, MRI scanner).
Briefly describe the following three categories of medical devices: Radiology & Imaging, Laboratory, and Diagnostics.
A 32-year-old patient named Daniel arrives at the emergency department with severe chest pain and shortness of breath. Which five medical devices could be used during his emergency assessment and treatment?
Classify the three risk levels of medical devices and give one example for each class.
Assign each of the following three patients to their appropriate specialized hospital clinic: Patient A has persistent chest pain and irregular heartbeat; Patient B is a 4-year-old child with persistent fever and loss of appetite; Patient C has knee pain and difficulty walking.
During emergency ambulance transit of an injured mother with breathing difficulties and an infant needing temperature control, identify two appropriate devices used and their roles.

Identify the hospital environment depicted in the image and state two essential medical devices located in this setting along with their functions.
The image shows an Operating Theatre (OT) or surgical suite. Two essential devices: 1. Operating Theatre (OT) Surgical Light: Provides high-intensity, shadowless illumination over the surgical field. 2. Operating Table: Safely supports and adjusts patient positioning during surgical interventions (other valid devices include the anaesthesia machine, patient monitor, and electro-surgical unit).
What is the definition and primary clinical function of a cardiotocograph (CTG)?
A Cardiotocograph (CTG) is an electronic diagnostic monitoring device used during pregnancy and labor to simultaneously record and display the Fetal Heart Rate (FHR) and uterine contractions.
If a cardiotocography (CTG) machine displays the Fetal Heart Rate (FHR) on screen but fails to print the FHR chart on paper, what three immediate steps should technical personnel take?

Identify the biomedical diagnostic device shown in the figure and state two critical operational safety procedures to observe during its use.
The device is an Electrocardiograph (ECG) machine. Two critical safety procedures: 1. Ensure the device and patient cables are properly grounded and electrically isolated to avoid microshock hazard. 2. Verify skin contact sites are clean and dry, use fresh conductive gel or proper electrode placements, and avoid placing electrodes over broken skin or uninsulated conductive surfaces.
Name the two transducers utilized in a Cardiotocograph (CTG) and specify the physiological parameter monitored by each.
List four standard physiological parameters monitored by a multi-parameter patient monitoring system.
Contrast the transmission mode and reflection mode of pulse oximeter (SpO2) sensors.
Describe Einthoven's Triangle, including the polarity and electrode attachments for Leads I, II, and III.
Einthoven's Triangle is an imaginary equilateral triangle centered on the heart formed by three standard bipolar limb leads: 1. Lead I: Negative electrode on the Right Arm (RA), positive electrode on the Left Arm (LA). 2. Lead II: Negative electrode on the Right Arm (RA), positive electrode on the Left Leg (LL). 3. Lead III: Negative electrode on the Left Arm (LA), positive electrode on the Left Leg (LL). (The Right Leg [RL] serves as reference ground).

Identify the diagnostic device shown in the figure and list five safety and operational procedures required before operating it.
The device is a Spirometer (Schiller Spirovit SP-1). Five procedures: 1. Fit a clean, single-use disposable mouthpiece or viral/bacterial filter to prevent cross-contamination. 2. Perform volume calibration using a certified calibration syringe (e.g., 3dm3 syringe). 3. Verify electrical cord integrity and battery charging status. 4. Ensure ambient conditions (temperature, barometric pressure, humidity) are properly zeroed/calibrated in the system. 5. Instruct and seat the patient comfortably to prevent falls due to hyperventilation or dizziness.
List four common clinical types of infusion devices.

Identify the two infusion devices shown in the image and describe their primary functional distinction.
Left: Syringe Pump; Right: Volumetric Infusion Pump. Functional distinction: The syringe pump is designed for precise, low-volume, and low-flow-rate delivery of concentrated, potent drugs (e.g., inotropes, anaesthetics). The volumetric infusion pump delivers larger volumes of intravenous fluids, medications, or total parenteral nutrition (TPN) over sustained periods at higher flow rates.
State two cardiac arrhythmias treatable with a manual defibrillator, and name the clinical condition associated with an Automated External Defibrillator (AED).
Manual Defibrillator: 1. Ventricular Fibrillation (VF). 2. Pulseless Ventricular Tachycardia (pVT). Automated External Defibrillator (AED): Sudden Cardiac Arrest (SCA) exhibiting shockable ventricular fibrillation or pulseless ventricular tachycardia.
Distinguish between the two operational modes of a defibrillator: Asynchronous mode and Synchronized mode.
State three primary functions of a hospital anaesthesia workstation.
Define the roles of the scavenging system, breathing circuit, ventilator, and vaporiser within an anaesthesia workstation.
Explain the four physical mechanisms of heat loss that must be managed to maintain neonatal body temperature.
Describe three good engineering handling practices for maintaining an optical spectrophotometer.
Describe the function and operating principle of the pCO2 and pO2 electrode systems used in an Arterial Blood Gas (ABG) analyzer.

Based on the optical microscope diagram, identify the components designated by letters A through F.
A: Eyepiece (Ocular Lens); B: Coarse and Fine Adjustment Knobs; C: Revolving Nosepiece / Objective Lens (40× shown); D: Specimen Stage (with Slide Clips); E: Condenser and Iris Diaphragm; F: Light Source (Illuminator).

Identify the laboratory equipment shown in the figure and name the two primary rotor types used in this device.
The device is a Laboratory Centrifuge (Hettich MIKRO 220). The two primary rotor types are: 1. Fixed-Angle Rotor (holds sample tubes at a rigid, fixed angle during rotation). 2. Swing-Out / Swinging-Bucket Rotor (allows buckets to swing horizontally perpendicular to the rotational axis during spinning).

Identify the medical imaging device shown and name three of its key structural or operational sub-assemblies.
The device is an Ultrasound Imaging System. Key components include: 1. Ultrasound Transducer / Probe (houses piezoelectric crystals). 2. Central Processing Unit (CPU) / Beamformer Console (processes returning acoustic echoes). 3. Video Display Monitor (visualizes real-time B-mode, M-mode, or Doppler images).
During Planned Preventive Maintenance (PPM) of a diagnostic X-ray machine, name three key parameters evaluated and the test analyzer used.
Key parameters: 1. Tube potential accuracy (kVp). 2. Exposure duration / timer accuracy (ms). 3. Radiation output linearity and repeatability (mAs or mGy). Test analyzer: Non-invasive X-ray Multimeter / Beam Quality Analyzer (with solid-state detectors or ionization chamber).
Azhar suffered a broken leg, chest swelling, and suspected internal brain bleeding following a road accident. Which radiology/biomedical diagnostic devices are indicated for each injury?
List five key components comprising a hospital Picture Archiving and Communication System (PACS).
Explain two primary distinctions between an Electronic Medical Record (EMR) and an Electronic Health Record (EHR) regarding data sharing and accessibility.
What are four core safety precautions a biomedical technician must execute prior to opening and troubleshooting a Switch Mode Power Supply (SMPS)?