53 Terms

1
New cards

The air entering a desiccant air dryer can have a maximum temperature of ___°F.

94

2
New cards

Drip lubricators must be installed no more than ___' away from the components that require lubrication.

10

3
New cards

A(n) ___ is a device designed to lower the temperature of compressed air to 35°F.

refrigerated air dryer

4
New cards

It takes __ cu ft of atmospheric air to produce 1.0 cu ft of compressed air at 100 psi.

7.8

5
New cards

Oil contamination in a pneumatic system can possibly come from ___.

overlubrication of the air compressor

6
New cards

At standard pressure and temperature, the weight of 1 cu ft of air equals ___ lb.

0.076

7
New cards

Pressure drops on pneumatic filters should not exceed ___ psi.

2

8
New cards

A properly maintained coalescing filter should have approximately ___ operational hours.

2000

9
New cards

___ is small quantities of liquid condensation.

Moisture

10
New cards

Most contaminants enter a pneumatic system through the ___.

air intake

11
New cards

A(n) __ is a device that removes water vapor from compressed air through adsorption.

desiccant air dryer

12
New cards

A(n) ___ is used to remove contaminants from the air before it travels to the inlet of the compressor.

intake filter

13
New cards

A(n) ___ is a heat exchanger used for cooling the discharged air from an air compressor.

aftercooler

14
New cards

Dew point is also known as ___.

saturation temperature

15
New cards

___ is the pressure differential between upstream and downstream airflow caused by resistance.

Pressure drop

16
New cards

A venturi is a tube that creates a(n) ___.

vortex

17
New cards

Surface-type elements are usually constructed of ___.

treated paper

18
New cards

___ is the conversion of a substance from a vapor state to a denser liquid state, usually initiated by a reduction in temperature during its vapor state.

Condensation

19
New cards

A(n) ___ is a pneumatic device that is used to filter, regulate, and lubricate compressed air before it reaches the point of work.

filter-regulator-lubricator (FRL)

20
New cards

The higher the temperature of the air, the higher percentage of ___ it can hold.

water vapor

21
New cards

Coalescing filters are sometimes referred to as ___ filters.

inline liquid filters

22
New cards

Solid contaminants in pneumatic systems are rated in ___.

micrometers/microns

23
New cards

___ is the amount of moisture in the air.

Humidity

24
New cards

Depth-type elements are typically constructed from a(n) ___.

bronze alloy

25
New cards

A(n) ___ is a pneumatic device that separates moisture from compressed air by forcing it to flow against baffles.

moisture separator

26
New cards

A(n) ___ is a device that injects a lubricant into the airflow.

lubricator

27
New cards

___ air is air that holds as much moisture as it is capable of holding.

Saturated

28
New cards

A(n) ___ is a normally-open pressure valve that is used to control downstream pressure.

regulator

29
New cards

A(n) ___ filter is a filter that removes contaminants from within a pneumatic system.

inline

30
New cards

___ air is air that is located inside a facility.

Ambient

31
New cards

Breathable air contaminated with oil can cause health hazards.

T

32
New cards

Intercooling reduces the temperature of the compressed air, as well as its volume, before it reaches the next stage.

T

33
New cards

Pneumatic components are never available prelubricated.

F; certain components are

34
New cards

Contaminants in a pneumatic system are different than those present in a hydraulic system.

F; similar

35
New cards

Desiccant material becomes saturated because adsorption can remove 99.9% of the water vapor in the air.

T

36
New cards

The temperature is a determining factor for the percentage of water vapor in the air.

T

37
New cards

Liquid contaminants can be as destructive as solid contaminants.

T

38
New cards

Air is always pushed into a pneumatic system, rather than pulled.

T

39
New cards

The filters used with most FRLs are different than inline filters.

F; similar

40
New cards

Ambient air is air that is located outside a facility.

F; atmospheric

41
New cards

A regulator can only be used alone.

F; alone or with filter/lubricator

42
New cards

The total amount of moisture that air is capable of holding varies based on the temperature of the air.

T

43
New cards

The inside air of a facility typically contains more airborne contaminants than outside air.

T

44
New cards

The higher the temperature of the air, the lower percentage of water vapor it can hold.

F; the lower the temperature

45
New cards

Coalescing filters are most effective when placed in the coolest locations in the system.

T

46
New cards

When an intake filter becomes clogged, the air compressor must work harder to acquire its air, which can cause the filter element to collapse.

T

47
New cards

Coalescing filters should be installed as far as possible from the point of work.

F; as close as possible

48
New cards

Lubricators must never be installed before a filter.

T

49
New cards

Remote intake filters are never installed in facilities that have contaminated air but need to keep the air compressors near the work devices.

F; are typically installed

50
New cards

Desiccant air dryers are normally placed in the warmest downstream location.

F; coolest

51
New cards

Explain how a regulator operates.

(1) Compressed air from the piping enters the inlet of the regulator. Compressed air then flows through the outlet and pilot ports.

(2) If system pressure is higher than the pressure of the main biasing spring, the piston moves up.

(3) As the piston moves up, the small biasing spring under the poppet forces the poppet to rise.

(4) As the poppet rises, the size of the orifice that the compressed air is flowing through decreases, reducing the airflow, thereby after the regulator.

52
New cards

Explain how solid contaminants can damage a pneumatic system.

Contaminated pneumatic equipment must work harder to maintain pressure, which leads to premature wear and wasted energy. Solid contaminants can also cause premature wear on seals, creating leaks within the pneumatic system and wasting energy.

53
New cards

List seven common solid contaminants found in pneumatic systems.

(1) dirt

(2) dust

(3) metal chips

(4) pipe scale

(5) rubber particles

(6) water droplet residue

(7) rust particles