1/47
Looks like no tags are added yet.
Acid
Donates a proton
Base
Accepts a proton
Buffer
A weak acid (HA) and conjugate base (A-)
Resists change in pH
Henderson-Hasselback Equation
pH = pKa + log [A-]/[HA]
pH depends on the ratio of [HCO3-] : [pCO2]
normal = ~20 : 1
Buffers
Act within seconds:
bicarbonate, phosphate, protein, and Hb
Respiration Buffer
1. 1-15 minutes
2. Increases or decreases pCO2 by changing resp rate
3. Hyperventilation
4. Hypoventilation
Hyperventilation
- Body is acidotic
- Lowers pCO2
- Increases pH
- Expels excess CO2
Hypoventilation
- Body is alkaline
- Raises pCO2
- Decreases pH
- Keeps pCO2
Renal Buffer
- takes hours to days to kick in
- can retain or excrete HCO3-
- can retain or excrete H+
Acidosis - excrete H+, retains HCO3-
Alkaline - retain H+, excretes HCO3-
Bicarbonate Buffer System
CO2 + H2O
carbonic acid - acids from metabolic processes, lactic acid from muscles due to exercising
Protein Buffer System
Low pH (acidic) - carboxylic group accepts H+
Neutral - Carboxylic acid is (-) and amine is (+) = neutral
High pH (alkaline) - amine group donates H+
Hemoglobin Buffer System
in circulation, there is high CO2
in RBC, CO2 converted to carbonic acid, converted to HCO3- + H+
Nonfunctional Hbs regulate pH
Base Excess
uses pH, pCO2, and Hb
Amount of BASE needed to titrate a strong acid to reach pH of 7.4 under Standard Temp and Pressure
Normal BE = 0
POS = metabolic alkalosis (excess bicarb)
- Treatment: flush bicarb with ammonium chloride
NEG = metabolic acidosis (lacks bicarb)
- Treatment: sodium bicarb
Respiration
Exchange of O2 and CO2
Occurs due to pressure/concentration gradients
Diffusion - gas moves from high conc. to low conc.
External Respiration
Inhalation of O2 and exhalation of CO2 in the lungs
Internal Respiration
Occurs in capillary beds and is the release of O2 to tissues and uptake of CO2 in order to remove it
-between cells and blood
Partial Pressure
Amount of pressure contributed by a gas to the total pressure
Measured in mmHg
Dalton's Law
total pressure of a mixture of gases is the sum of the partial pressures that make up the mixture
(pO2 + pCO2 = blood gas; total pressure)
Henry's Law
The amount of gas dissolved in a solution is directly proportional to the partial pressure of the gas and the solubility of the gas
Hypercapnia
1. HIGH pCO2 in arterial blood
2. Can be caused by
- breathing in too much CO2
- decreased alveolar ventilation (drugs)
Hypocapnia
1. LOW pCO2 in arterial blood
2. Can be caused by:
- hyperventilation (excess CO2 exhaled)
- Exercise
Arterial pCO2 Reference Range
35 - 45 mmHg
HCO3- Reference Range
22 - 29 mmol/L
Oxygen-Hb Dissociation Curve
1. sigmoidal curve from increasing efficiency of Hb to bind O2 once some O2 has already bound
2. pO2 reaching tissue depends on binding capacity of Hb to O2 and Hb concentration
Affinity of Hb for O2 Depends on:
1. 2,3-bisphosphoglycerate (2,3-BPG; RBC glycolysis byproduct)
2. pH
3. Temperature
4. pCO2
5. CarboxyHb
6. Methemoglobin
Increased Hb Affinity for O2
Decrease in:
Temp, 2,3-BPG, pCO2
- left shift on curve results in INCREASED affinity for O2
- Hb will not release O2
-High affinity - LOW dissociation
Decreased Affinity for O2
Increase in:
Temp, 2,3-BPG, pCO2
-right shift results in DECREASED affinity for O2
- Hb will dissociate O2 and release to tissues when needed
- low affinity - high dissociation
Bohr Effect
pH
decrease in pH results in Right Shift (acidosis)
- decreased affinity, INCREASED dissociation
- Release O2
Increase in pH results in Left Shift (alkalosis)
- increased affinity, DECREASED dissociation
-do not release O2
Determining Oxygen Saturation in Blood
1. Oxygen saturation (sO2)
2. Fractional oxyhemoglobin (FO2Hb)
3. Estimated oxygen saturation (O2Sat)
Factors that Affect Oxygen Transport
1. pO2
2. Diffusion of O2 across alveolar membranes
3. Affinity of Hb for O2
-including non-functional Hb varieties (reduce affinity)
4. Decreased RBC number
Oxygen Saturation (SO2%)
1. Calculation of % of functional Hb that is saturated with O2
2. Normal = >95%
3. Indirect measurement by pulse oximetry
4. [oxyHb] / ([oxyHb] + [deoxyHb]) x 100= SO2%
Hypoxia
low pO2 and low SO2%
- from lack of O2
Causes: suffocation, drowning, low ambient O2, venous/arterial blood mixing, pneumonia, respiratory distress
-environmental/ outside the body
Cyanosis
LOW SO2% from non-functioning Hb
Causes: CO exposure, environmental exposure, medications, congenital
Hypoxemia
LOW arterial oxygen
Causes: decreased pulmonary diffusion or alveolar spaces, obstructed airways, emphysema
-internal issue
-Hb has low SO2
Fractional Oxyhemoglobin (FO2Sat)
1. The fraction of the Hb that is saturated with O2
2. Includes concentrations of all Hbs (functional and non-functional)
3. Measured by co-oximetry
4. [oxyHb] / [Total Hb] = FO2Sat
5. Normal= 0.90 - 0.95
Estimated Oxygen Saturation (O2Sat)
1. not directly measured
2. estimated from measured pH, pO2, and using empirical equations
3. assumes normal O2 affinity for Hb and normal factors elsewhere
4. values can vary by as much as 6%
5. Use is discouraged
Blood Gas Analysis
Directly Measured Parameters:
1. pH
2. pCO2
3. pO2 (Clark electrode)
Calculated Parameters:
1. Bicarbonate = 10(pH 6.11) x pCO2 x 0.0307
2. Carbonic acid
3. Total CO2
4. Saturated Oxygen % (sO2)
5. Base Excess
Blood Gas Analyzers
Can Expand with more ISEs and measure:
Na+
K+
Ca2+
Cl-
glucose
lactate
different forms of Hb (co-oximetry)
pH Electrode
1. Glass membrane with AgCl solution in inner compartment
2. H+ ions at the external surface of glass membrane attract Cl- inside the electrode
3. Causes more Cl- to leave AgCl, creating Ag+ ions
4. Creates potential (potentiometry)
pO2 Electrode
1. Amperometric Clark electrode
2. Oxygen-permeable membrane
3. Platinum Cathode
4. Ag/AgCl anode
pCO2 Electrode
1. Uses pH electrode with gas permeable membrane
2. Teflon, silicone, polypropylene
3. Phosphate buffer
4. Ag/AgCl electrode
5. CO2 diffuses thru membrane, equilibrates with bicarb, then dissociates to H+ and HCO3-
6. Results in pH change
7. creates potential (potentiometry)
Pulse Oximetry
1. Spectrophotometric
2. Red light absorbed by deoxygenated blood
3. IR light absorbed by oxygenated blood
4. Relative absorption of red and IR used to calculate arterial blood oxygen saturations
Blood Gas Control Material
For pCO2 and pO2:
1. RBC or synthetic fluorocarbon material with normal Hb and HCT
2. Must be run as soon as it is opened to prevent drop in pCO2 and rise in pO2 levels
For pH:
1. Aqueous buffer
Collection of Blood Gas Specimens
Arterial Blood is specimen of choice
-capillary blood is similar
-venous blood is LAST choice (only measure pH and pCO2)
NO TQ used - blood stasis low pH and pO2
NO hemolysis
NO clots
Mix Well - expel air bubbles, mix by rolling
Transport on ice; analyze within 1 hour
room temp - stable for 30 min
KEEP ANAEROBIC until analyzed
Prepackaged Blood Gas Collection Kits
1. Self-filling syringe with Li heparin; premeasured amount
2. Rubber block for needle
3. 23-gauge needle or smaller
Analytical Error in Blood Gas Analysis
1. Calibration
2. Inadequate mixing of blood
3. Lack of temp control
Blood Gas Pre-Analytical Errors
if not assayed ASAP:
-low pH - glucose converted to lactate
- high pCO2 - tissue respiration (HCO3-)
-low pO2 - oxygen consumed by cell metabolism
If exposed to air:
-high pH - pCO2 decreases
-low pCO2 - low CO2 in air
-high pO2 - high O2 in air
Blood Gas: Sample Temperature
LOW Temp:
-high affinity of Hb for O2 (less O2 dissociates)
- low pO2, high pCO2, low pH
HIGH Temp:
- increased glycolysis and pCO2 (more O2 dissociates)
-high pCO2, high pO2, low pH