1/74
RT 204
Recorded Detail
refers to the sharpness and clarity with which anatomical structures are represented in a radiographic image
Clearly defined anatomical margins.
Visibility of fine anatomical structures.
Minimal image blurring.
Accurate representation of structural boundaries.
Characteristics of good recorded detail
Supports accurate anatomical evaluation.
Helps demonstrate subtle anatomical details.
Contributes to diagnostic image quality
Importance of good recorded Detail
Motion in radiography
refers to movement of the patient, anatomical structures, or imaging equipment during the exposure
Motion Unsharpness
Motion blur is called
Loss of image sharpness caused by movement during exposure.
Produces blurred or indistinct anatomical margins.
Reduces recorded detail
Motion Unsharpness
Blurred anatomical margins.
Reduced image sharpness.
Loss of fine structural detail.
Decreased visibility of small anatomical structures.
Motion unsharpness is characterized by
Recorded Detail
Movement during exposure results in loss of ____________
Involuntary Motion
Voluntary Motion
2 types of Motion in Radiography
Voluntary Motion
refers to movement that occurs under conscious control
Patient movement during exposure.
Failure to remain still.
Movement of the extremities.
Movement caused by discomfort or anxiety.
Failure to follow breathing instructions.
Examples of Voluntary Motion
Proper patient instructions.
Clear communication.
Comfortable positioning.
Appropriate immobilization when indicated
Voluntary motion methods of control
Involuntary Motion
movement that occurs without conscious control
Cardiac pulsation.
Respiratory movement.
Peristalsis.
Muscle tremors.
Muscle spasms.
Vascular pulsation.
Examples of Involuntary motion
Use appropriately short exposure times.
Provide proper patient support.
Use immobilization when appropriate.
Select appropriate exposure factors.
Involuntary Motion Methods of control
Equipment Motion
Patient Support Instability
What are the other sources of Motion?
Movement of the X-ray tube.
Instability of the tube support.
Movement of the image receptor.
Equipment motion
Unstable positioning devices.
Improper patient support.
Movement of the examination table
Patient Support Instability
Secure the imaging equipment.
Ensure proper positioning.
Check equipment stability before exposure.
the prevention of other sources of motion
Effects of Motion on Image Quality
Motion can compromise the diagnostic usefulness of a radiographic image
Reduced recorded detail.
Blurring of anatomical margins.
Loss of visibility of fine structures.
Decreased spatial resolution.
Reduced diagnostic confidence.
Possible need for repeat examination
Motion can results in:
Exposure time.
Speed of movement.
Magnitude or amplitude of movement.
Direction of movement relative to image geometry
The degree of motion unsharpness depends on several factors
Longer exposure time increases the opportunity for motion.
Faster movement increases motion unsharpness.
Greater displacement during exposure produces more blur
Factors affecting motion unsharpness: General Principle
Exposure time and motion
is the duration during which the X-ray tube produces radiation for image acquisition
Longer Exposure
Greater opportunity for motion
Shorter Exposure
Less opportunity for motion
TRUE
Short exposure time helps minimize motion unsharpness.
The role and mA and Exposure Time
is the relationship between tube current, exposure time, and mAs is: mAs = mA × exposure time (seconds)
mAs = mA x Exposure time (seconds)
What is the formula of mA and exposure time?
Increasing mA
___________ while proportionally decreasing exposure time can maintain the same mAs
Patient Related Measures
Equipment Related Measures
Techniques to minimize motion
Use appropriately short exposure time.
Select suitable exposure factors.
Use appropriate immobilization devices.
Ensure equipment stability
Equipment Related Measures
Explain the procedure clearly.
Give simple and understandable instructions.
Ensure patient comfort.
Provide proper support and immobilization when appropriate
Patient Related Measures
TRUE
Proper preparation before exposure is essential.
TARGET OBJECT FILM ALIGNMENT
TOF
The X-ray tube focal spot (target).
The anatomical structure being examined (object).
The film or image receptor (IR)
Target–Object–Film (TOF) alignment refers to the geometric relationship among
Minimize geometric distortion.
Maintain accurate anatomical representation.
Produce diagnostically acceptable images
Purpose of Proper Alignment
Target
Object Film/ Image Receptor
3 Components TOF
Target
Refers to the focal spot of the X-ray tube.
Source of the X-ray beam
Object
The anatomical structure being examined.
Example: hand, wrist, chest, or knee.
Film/ Image receptor
The device that receives the transmitted X-rays.
Records the radiographic image.
The target or Focal Spot
is the area of the anode target where electrons interact to produce X-rays
Serves as the origin of the X-ray beam.
Has a direct influence on geometric image quality.
A smaller effective focal spot generally produces less geometric unsharpness
The important characteristics of target or focal spot
Smaller focal spot
Less focal-spot geometric unsharpness, all else being equal
The Object
The object refers to the anatomical structure being examined.
Bones
Joints
Soft tissues
Organs
Examples of Object
Proper anatomical placement.
Appropriate relationship to the image receptor.
Correct centering.
Avoidance of unnecessary rotation or tilt.
Positioning Considerations of Object
The film or Image Receptor
receives the transmitted X-ray photons and records the radiographic image
Computed radiography imaging plate.
Digital radiography flat-panel detector.
Traditional radiographic film.
Examples of film or image receptor
Correct placement.
Appropriate orientation.
Proper alignment with the anatomical part.
Adequate coverage of the region of interest
Positioning Considerations of Film/ or Image receptor
1.The object should be parallel to the image receptor.
2.The central ray should be perpendicular to the object and image receptor.
3.The central ray should be accurately centered to the anatomical region of interest
The ideal Target-object-film relation for a routine projection intended to minimize shape distortion
Mnemonic PPC
Part parallel to the image receptor.
Perpendicular central ray.
Correct centering.
Reduce shape distortion.
.Control magnification.
.Improve anatomical representation.
.Maintain appropriate spatial relationships.
.Produce diagnostically useful images
Importance of proper alignment that helps
Foreshortening.
Elongation.
Unequal magnification.
Unnecessary anatomical overlap
Poor alignment may cause in
Geometric Distortion
refers to the misrepresentation of the actual size or shape of an anatomical structure.
Foreshortening
Elongation
Two major forms of shape to distortion
Incorrect object–image receptor alignment.
Incorrect central ray angulation.
Improper positioning
Factors contributing to distortions
Foreshortening
occurs when the radiographic image appears shorter than the actual object
The object is not parallel to the image receptor.
With the central ray perpendicular to the image receptor, an angled object may appear shortened in its projected dimension.
Common Geometric causes: Foreshortening
Compressed or shortened appearance.
Results to foreshortening
Elongation
occurs when the radiographic image appears longer than the actual object
Incorrect central ray angulation relative to the object and image receptor.
For example, an object parallel to the image receptor may appear elongated when the central ray is angled relative to the receptor.
Common Geometric causes: Elongation
Stretched or lengthened appearance
Results of elongation
TRUE
The important thing is to understand that distortion is determined by the relationship among the object, central ray, and image receptor
Central Ray Alignment and Centering
is the central portion of the X-ray beam
Appropriate CR direction.
Correct angulation.
Proper centering.
Correct relationship with the object and image receptor
Proper CR alignment involves
Reduces geometric distortion.
Ensures proper anatomical coverage.
Supports consistent image quality
Importance of central ray alignment
Hand and wrist
Foot
Knee
Clinical application of alignment are always consider the required positioning criteria for the specific placement of proper alignment
Hand and Wrist
Proper positioning of the hand relative to the image receptor.
Avoid unnecessary rotation or tilt.
Foot
Appropriate object positioning and projection-specific CR direction
Knee
Correct anatomical positioning and CR alignment
Motion
Target object film alignment
Two important considerations in radiographic image quality
True
A diagnostic radiograph requires both adequate sharpness and appropriate geometric representation
Motion
Affects image sharpness.
Reduces recorded detail.
Controlled through appropriate exposure time, positioning, and immobilization
Target Object Film Alignment
Affects image geometry.
Influences magnification and shape distortion.
Controlled through proper positioning and central ray alignment.