Why do we do speech audiometry?
-Speech measures provide important info:
regarding effects of reduced sensitivity on communication
As a cross check of other test results (i.e. PTA/SRT)
To assist with differential diagnosis
For rehabilitative interventions and verification
need for and benefit from auditory prosthetics
we also test “suprathreshold” speech processing abilities because they can provide
diagnostic information
information about communicative function
Why not just measure pure tone thresholds instead of speech audiometry?
PT thresholds aren’t always as predictive of speech understanding abilities
Types of speech tests
-Detection/awareness
analogous to pure tone threshold detection
-Discrimination
Same/different task
-recognition
requires ability to label the stimulus
Point to, write or repeat the stimulus
-Comprehension
requires understanding of the stimulus meaning
Which types of speech tests can be part of the diagnostic test battery?
-detection/awareness
-recognition
Speech test materials
-single syllable phonemes
-multisyllabic nonsense syllable
-words
monosyllabic words
bisyllabic (spondee) words
-sentence materials
nonsense sentences
low context sentences
high context sentences
running speech
which speech test materials do we use?
-the most appropriate material depends on your test purpose
diagnostic assessment?
communication assessment?
rehabilitative evaluation?
Performance intensity (PI) Functions for speech
-shows the change in speech understanding with changes in speech level
-note that for the same speech level, scores can vary dramatically depending on the test materials!
Factors affecting PI functions
-Task type
detection versus recognition
open versus closed set
number of items
-Context
better understanding at lower levels with high context materials
-Familiarity
better understanding at lower levels for familiar vs unfamiliar words
-Talker proficiency
clear speech vs conversational
-Calibration
the relationship between dB HL and dB SPL for recorded speech materials is variable!
Diagnostic Battery: speech tests
-Speech recognition threshold (SRT)
also speech reception threshold (SRT) and spondee threshold (ST)
speech recognition is preferred
-Speech detection threshold (SDT)
also speech awareness threshold (SAT)
SDT is preferred
-Word recognition score (WRS)
also speech discrimination (SDS) or word discrimination score (WDS)
WRS is preferred
What is SRT?
-minimum hearing level (dB HL) for speech at which an individual can recognize approximately 50% of the speech materials
hearing threshold for speech
-Test materials
spondee (bi-syllabic) words
two syllable words with equal stress on each syllable.. airplane, baseball…
Why measure SRT?
-validate pure-tone thresholds
SRT (in dB HL) should be very close to PTA (in dB HL)
very important cross check
-Quantify hearing loss for speech
face validity
-provide a reference level for other speech tests
ex: word recognition
-Estimate hearing loss in infants and young children (who cannot do pure-tone audiometry)
-assess/compare hearing aid benefit for speech
Why are PTA and SRT related?
-if you can’t hear the speech you can’t recognize and repeat the word…
speech banana
What speech material should we use to measure SRT?
-the “best” speech material depends on the test purpose
SRT purpose: find “threshold” for hearing speech
Why use spondees?
-for a threshold speech test, stimuli should:
be familiar to the listener
be phonetically dissimilar (not rhyming)
contain a normal sampling of speech sounds
be representative of “normal” speech
have equal difficulty across stimuli (homogeneity)
this results in a steeper, stable, psychometric function which helps make the test sensitive to variations in threshold
-original spondee words met these criteria
-Steep PI function for spondees suggests similar difficulty across test items (homogenous)
lends itself to sensitive and reliable threshold estimates
spondee scores increase from ~20-80% correct over a 6 dB range
How do we measure SRT?
-2 primary methods
ASHA method:
currently used by veterans administration for compensation and pension (C&P) exams
Clinical method (martin & Dowdy, 1986)
based on the modified Hughson-westlake procedure for measuring PT thresholds
you’ll use this method in clinic
Instructions for SRT
-specific instructions can vary but must be understandable by the patient
familiarize them with the words
details to follow
explain the nature of the task
tell them how to respond
-instructions should emphasize:
only respond using words from the test
i.e. this is a closed set task
respond even when faint, guessing is o.k.
-for example, after familiarization:
“ok, I am going to say the same words again and I want you to repeat them back. But this time they are going to get very soft. repeat the words back as best as you can, and if you are not sure, take your best guess.”
Familiarization phase
-this phase ensures:
the test vocab is familiar
the patient can auditorily recognize each word
the clinician can understand the patient’s responses
-to familiarize, give them a list of the test words
present speech to both ears at a comfortable level
face to face/MLV is ok but no visual cues
eliminate words that are difficult to identify during the familiarization phase
How many spondees to use for SRT?
-likely vary by clinician
-research says using recorded stimuli, a 15 word subset provides similar results to the full 36 word set
ASHA guidelines provide 18 word half-lists and a 15 word short list
but no work using MLV or for various talkers
ASHA Method SRT - Obtaining start level
-first, you have to find a starting level
set the level 30-40 dB above presumed SRT
or 50 dB HL if no estimate is possible
Present one word,
if correct, descend 10 dB
if incorrect, ascend 20 dB until a correct response is obtained,
then descend in 10 dB steps
continue descending in 10 dB steps until…
one word is missed
once one word is missed, present a second spondee at the same level
if they get that spondee correct, decrease level another 10 dB
Continue until two spondees are missed at the same level
Once 2 spondees are missed at the same level, increase the level by 10 dB. this is your starting level
i.e. 10 dB above the level where 2 words were missed
ASHA method SRT - Threshold testing
-Descending procedure
you can descend using either a 2 dB or 5 dB step size
-when using a 2 dB step size:
present 2 words at the starting level and at each successive lower level
-for both step sizes, you must get five out of the first six words correct
if not, increase start level by 4-10 dB and start again
-continue presenting 2 (or 5) words at each level and decrease in 2 (or 5) dB steps until stopping rules are met
-stopping rules: testing ends (stop decreasing levels) when:
5 of the last 6 words are incorrect (2 dB step size)
5 words presented at a single level are incorrect (5 dB step size)
-once you’ve met a stopping rule, you can calculate your SRT (threshold)
ASHA Method SRT - Calculating threshold
SRT = start level - # correct + CF (correction factor)
2 dB CF = 1 dB
5 dB CF = 2 dB
Clinical SRT Method
-Martin and Dowdy
uses a modified Hughson-Westlake approach
use the same familiarization procedure as for the ASHA method
-Starting level - present a single word at a given level
30 dB, increase to 50 dB, then increase 10 dB steps until correct response
after correct response, decrease 10 dB. this is your starting level
-Present a single word at each level
down 10 dB; up 5 dB procedure
-Threshold: minimum of three correct responses, on ascending trials, at one level
many audiologists use “2 out of 3” rule
Martin and Dowdy’s method pros and cons
-Pros:
SRTs (recorded stimuli) and PTA - strongly correlated (r=.97)
Test time ~2.5 minutes (similar or a bit faster than ASHA method)
-Cons:
mean SRT was ~5 dB>PTA
only ~50% of SRTs ± 5 dB of PTA
compared to ~78% for the current ASHA method
ASHA method vs Martin and Dowdy SRT method
-ASHA method provides better agreement between PTA and SRT
-less empirical work using MArtin and Dowdy method but…
it appears to achieve the goal of validating PTA
it is fast and familiar to clinicians
it is being used routinely without evidence of systematic problems
-Either is fine!
Variations on the SRT theme
-Variations in response mode: whatever you pick it must be appropriate for the patient
verbal or written repetition
closed set picture pointing (use smaller set size)
-Presentation mode- MLV versus recorded
flexibility versus standardization
some work (and ASHA guidelines) suggest both methods are valid
Measuring spondee SRTs via MLV
-both spondaic syllables need to peak at 0 dB on the meter
-Adjust VU meter gain so you can talk naturally and peak the meter at 0 on both syllables
Reliability: MLV vs Recorded
-when experienced audiologists conduct testing both methods are reliable
similar mean test-retest differences (both ~<1 dB)
strong, positive test-retest correlations
but stronger correlation for recorded (.96) vs MLV (.89) presentation
SRT-PTA correlations are similar, and high, with both methods (both ~.91-.92)
Mean SRT-PTA differences are small and similar
but a little smaller for recorded, compared to MLV
SRT>PTA by ~1 dB for recorded and SRT<PTA by ~3 dB for MLV
Clinical guidelines for “agreement” between PTA and SRT
-Brandy suggests that aabsolute differences between SRT and PTA (2 or 3 frequency) of
<7 dB- good agreement (no concerns)
7-12 dB- fair agreement (not great, but ok)
>13 dB- poor agreement (look for cause of discrepancy)
-The VBWC follows this protocol
others assume an SRT ± 10 dB of PTA is adequate
-based on both criteria the martin and dowdy method is acceptable
Speech detection threshold
-only obtain SDT if SRT not possible
e.g. speech/language issues, cognitive impairment
-may use descending or ascending approach
commonly use modified hughson-westlake method
-Materials: most speech materials work
spondees, multiple words, running speech, single word repeated over and over
-SDT should approximate best PT threshold (250-4000 Hz)
within 5-10 dB
If difference >10 dB then question your results
-SDTs are generally better (lower) than SRT
When to mask SRT conceptually and how much
-mask if SRT of TE could be result of cross hearing, enough to effectively mask the NTE
-Initial masking level:
SRT (NTE) + 10 dB safety factor
same as pure tone masking
-Maximum masker level:
compare BC thresholds in TE to masker level in the NTE. You may be overmasking if:
Masker level-IA is >BC (TE) (PTA at .5, 1, and 2 kHz) or
Masker level - IA is > best BC (TE) (.5, 1, 2, or 4 kHz)
When to mask SRT Quantitatively
-Mask whenever the test ear and non-test ear SRTs differ by >IA
assume speech IA = 45 dB (supra-aural) or 55 dB (inserts)
-Mask if:
SRT (TE) - SRT (NTE) (or BC NTE PTA at .5, 1, 2, kHz) >45 dB
Some rx: SRT (TE) - Best BC (NTE) (.5, 1, 2, or 4 kHz) >45 dB
General methods for assessing speech recognition
-there are two primary methods for quantifying speech understanding
adaptive tasks- level/SNR varies across individuals
outcome: level/SNR needed for a fixed performance level
level/SNR needed to get 50% correct (or 71% correct, etc.)
we use this approach to determine our clinical SRT
Fixed level/fixed SNR tasks- % correct varies
outcome: a “percent correct” score for a given level/SNR
-Word recognition testing in quiet is a “fixed level” task that is a part of the standard diagnostic test battery
-both methods have advantages and disadvantages
Slide 4