1
New cards

power supply to mobile homes shall be a feeder assembly consisting of not more than one listed ? - ampere mobile home power supply cord or a permanently installed feeder

50

2
New cards

The area around an outdoor, grade level gasoline dispensing pump extending up 18 inches above grade level and within? horizontally is classified as a class 1 division 2 location

20 feet

3
New cards

each patient bed location shall be provided with a minimum of ? receptacles with specific circuits they shall be connected to

14 receptacles

4
New cards

capable of being inadvertently touched or approached nearer than a safe distance by a person defines which of the following terms

exposed (as applied to live parts)

5
New cards

which article is for stationary or stands by batteries

480

6
New cards

transformers exceeding 112.5 kilovolt amps shall not be located within ?

12 inches of conbustable materials of buildings…. 450.22

7
New cards

manifaurig wiring system definition

a system containing component parts that are assembled in the process of manufacture and cannot be inspected

8
New cards

LED sign illumination system

articles 100

9
New cards

what do you need at disconnecting means

a directory

10
New cards

how many respectables are permitted office lighting furnishing lighting accessories

receptacles shall not be permitted in lighting accessories….. this is in 605.6 c

11
New cards

article 668

scope of this article

12
New cards

irrigation cable for electrically driven irrigation machines is required to be supported at intervals not exceding?

4 feet

13
New cards

where shall cable trays are not to be used

in hoist ways or where subject to physical damage

14
New cards

cable trays splices and type MV cable joints made and insulated by approved methods shall be permitted to be located within a cable tray provided they are?

accessible

15
New cards

the definition of cable tray system

article 100

16
New cards

cable tray shall have? strength and rigidly to provide adequate support for all contained wiring

suitable

17
New cards

surface metal raceway shall not be used where the voltage is? or more between conductors unless the metal has a thickness of not less than 0.040 in nominal

300 v

18
New cards

surface metal raceways and associated fitting shall be ?

listed

19
New cards

surface metal raceways shall not be used where subject to severe physical damage unless otherwise ?

approved

20
New cards

covers and accessories of non metallic materials are used on surface metal raceways, they shall be? for such use

identified