e- therapy

55 Terms

1
New cards

Most clinical useful energy range for electron therapy

6 - 20 MeV

2
New cards

electron therapy treats…

superficial tumors

  • less than 5 cm deep


3
New cards

main uses of e- therapy

treatment of skin and lip cancers

chest wall irradiation for breast cancer

administering boost dose to nodes

treatment of head and neck cancers

4
New cards

2 inelastic collisions w/ atomic e-

ionization & excitation

5
New cards

inelastic collisions

KE can be lost producing:

  • ionization or excitation

  • converted to brems photons


6
New cards

ionization/excitation is dominant in

lower atomic number

7
New cards

brems is dominant in

high atomic number

high E

8
New cards

elastic collisions w/ atomic e-

electron-electron scattering

9
New cards

elastic collisons

KE is not lost but redistributed among particles after collision

10
New cards

collisional vs radiative processes

collisional: e- interacting w/ e- surrounding atoms

radiative: brems (e- passing by nucleus)

11
New cards

sum of collisonal and radiative losses

total mass stopping power

12
New cards

Gradient

rate of change of a value (dose) w/ a change position

(basically change in dose over change in distance)

13
New cards

beyond what range is the dose due to x-ray contamination of the beam

Practical range

E/2

(indicated by the tail on the depth dose curve)

14
New cards

most useful treatment depth of electrons is at what % of the depth dose

90%

15
New cards

estimate beam E based on depth dose curves

knowt flashcard image
16
New cards

dmax for co-60

0.5 cm

17
New cards

dmax for 4 MV

1

18
New cards

dmax for 6 MV

1.5 cm

19
New cards

dmax for 10 MV

2.5 cm

20
New cards

dmax for 15 MV

3 cm

21
New cards

dmax for 18 MV

3.5 cm

22
New cards

skin sparing vs e-

e- do not provide skin sparing

(provide depth sparing)

23
New cards

increasing E will …… to percent surface dose for e-

increase

24
New cards

how is field size varied for e-

variable jaws are fixed

applicators (cones) change the size of the field

25
New cards

for smaller fields what happens to the dmax

dmax shifts toward the surface

26
New cards

as field size increase the output factor…

increases

due to extra scatter from sides adding to direct beam

27
New cards

virtual source

intersection point where the beam appears to diverge from a point source

  • right before scattering foil


28
New cards

e- vs inverse square law

they don’t follow it

  • because of heavy scattering and no true point source


29
New cards

scattering foil

widens the e- beam

(second may be used to improve flatness of beam)

30
New cards

most e- beam treatments are planned for

single field techniques

31
New cards

beam E is set to cover target volume at

90 to 95% isodose curve

32
New cards

E is decided on what 3 factors

  • depth of target

  • minimal target dose required

  • acceptable dose to critical structures


33
New cards

block margins for photons vs e-

photon = 0.5 - 1 cm

e- = 1.5 - 2 cm

34
New cards

larger skin obliquity = ….. dose

larger dose

35
New cards

higher E = … photon tail

increased photon tail

36
New cards

sharp edges can be smoothed with a

shaped bolus

37
New cards

CET

coefficient of equivalent thickness

38
New cards

what is CET used for

approximates dose when there is tissue inhomogeneities by comparing it to a uniform slab (equivalent thickness) of water

39
New cards

bolus is used in e- beams to

  • flatten out irregular surface

  • reduce penetration of e- to parts in field

  • increase surface dose


40
New cards

bolus is measured againist what

water

41
New cards

risks of overlapping/abutted fields vs seperated fields

overlapping - risks overdosing

seperated - risks underdosing

42
New cards

when e- and photon fields are abutted which side will have the hotspot vs coldspot

e- will have coldspot

photon field will have hotpsot because of how e- scatter laterally

43
New cards

what MeV range is used for TSI

2 - 9 Mev

44
New cards

2 types of TSI treatment categories

translational technique

large field technique

45
New cards

translational technique

pt lies on a motor driven couch and moved across the beam

(or pt stationary and beam is moved across pt)

  • uses strontium-90


46
New cards

Large field technique

scattering e- through wide angles and large treatment distances

  • pt treated standing w/ 4 to 6 fields equally spaced

  • stanford technique


47
New cards

limiting factor for TSI

x-ray contamination

48
New cards

stanford technique

uses 6 fields (AP, PA, 4 obliques) (all 60 degrees apart)

3 dual fields per day

  • AP, 2 posterior obliques

  • PA, 2 anterior obliques


49
New cards

90% isodose at

E/4

50
New cards

80% isodose at

E/3

51
New cards

50% isodose at

E/2.5

52
New cards

Practical range (Rp) at

E/2

53
New cards

higher E = .. contamination in e- beam

more contamination

54
New cards

penumbra is more noticeable on what field size

smaller field sizes

55
New cards

rate of E loss of e- >= 1 MeV is

2 MeV/cm