1/17
Looks like no tags are added yet.
accuracy
degree of closeness between measured & true value
precision
degree of closeness between values obtained in repeated measurements
reliability
degree of consistency in scientific measurements --> repeated exp have similar results
validity
degree to which an experiment investigates what it is intended to study
random error
differ unpredictably from value + individual differences between samples/environmental factors (can be averaged out)
systemic error
all values shift consistently in one direction from true value + poor experimental design + calibration error (error would be reproduced in retrials)
choice of measurement method: reading error
taking measurements with quantities smaller than half of limit of reading --> use measuring instruments with higher sensitivity + use digital measuring tools
choice of measurement method: qualitative measurement
comparing results using subjective terms --> take quantitative measurements (objective measurements e.g. height in cm)
choice of range/interval: inappropriate range/interval
result in incomplete data + invalid conclusion --> conduct trial runs to determine appropriate range + use smaller intervals
calibration of measuring instruments: zero error
measuring instrument not set to zero before measurement --> calibrate measuring instruments properly
calibration of measuring instruments: without using standard reference
readings of pH meter are inaccurate if not calibrated in standard buffer solution --> calibrate measuring instruments properly
human error: parallax error
scale on measurement instrument/meniscus is read at an incorrect level --> ensure eyes are level with scalee/mensicus to minimize distortion
human error: subjective judgement
endpoints of experiments may vary from person to person --> involve multiple observers to minimize bias + use color chart to identify endpoint color
3 key elements of reliability
precision: consistency of results from rep measurements within same exp
repeatability: consistency of measurements made by same person with same equipment
reproducibility: consistency of measurements made by diff people/diff equipment
improve reliability
multiple trials:
- ensure consistency (inc precision)
- calc average (inc repeatability)
repeat entire exp:
- same set of equip (inc repeatability)
- diff set of equip/person (inc reproducibility)
reduce sampling error (minimizes dec in precision):
- random sampling --> avoid selection bias
- inc sample size --> average out individual variations
evaluating validity - how well does exp design align with aim
importance:
ensure exp is well suited to achieve aim
measure to improve validity:
pick most suitable parameter for measuring DV
evaluating validity - how well exp design eliminates effects of confounding factors
importance:
ensure change is only caused by IV
measure to improve validity:
keep CV constant
improve validity
proper choice of experimental design: evaluate strengths & drawbacks of diff setups --> pick best
careful design of exp to ensure fair testing:
- suitable controls and CV must be constant
- randomly assign samples to exp/control groups --> ensure variations in internal factors are evenly distributed
- take necessary precautions