Kitchen Countertop Receptacle Height Limit

The maximum height of a receptacle outlet above a kitchen countertop per PEC is 500 mm500\,\text{mm}.

2
New cards

Show Window Receptacle Spacing

The minimum distance required between receptacle outlets installed in a show window per PEC is 3 meters3\,\text{meters}.

3
New cards

Dwelling Unit Hallway Receptacle Requirement

The minimum hallway length in dwelling units that requires at least one receptacle outlet is 3 meters3\,\text{meters}.

4
New cards

Appliance Receptacle Outlet Maximum Distance

The maximum permissible distance of an appliance receptacle outlet from its intended location is 1800 mm1800\,\text{mm}.

5
New cards

Minimum Feeder Ampacity (Motor + Non-Motor Loads)

Calculated as 125%125\% of the motor full-load current (FLC) plus the other non-motor load currents.

6
New cards

One-Family Dwelling Outdoor Receptacle Maximum Height

The maximum permissible height of an outdoor receptacle outlet in a one-family dwelling is 2000 mm2000\,\text{mm} above grade.

7
New cards

Buchholz Relay

A protective relay utilized specifically for detecting internal faults in oil-immersed transformers.

8
New cards

MHO Relay

The protective relay preferred for detecting phase faults on long transmission lines.

9
New cards

Negative Sequence Current Heating Protection

A specialized protective scheme applied specifically to protect generators against rotor heating.

10
New cards

Load Bus

A power system bus where the voltage magnitude and phase angle are both unknown.

11
New cards

SF6SF_6 Circuit Breaker

A type of circuit breaker offering the highest reliability and requiring the minimum amount of maintenance.

12
New cards

Ferranti Effect

The phenomenon where the receiving-end voltage of a transmission line exceeds the sending-end voltage under no-load or lightly loaded conditions.

13
New cards

Arcing Ground

A destructive high-voltage phenomenon that is eliminated through effective neutral grounding.

14
New cards

Normal Operating Frequency (Philippine Grid Code)

The standard frequency band maintained between 59.7 Hz59.7\,\text{Hz} and 60.3 Hz60.3\,\text{Hz}.

15
New cards

Normal Grid Operating State Loading Limit

The condition where transmission equipment loading is maintained below 100%100\% of its continuous rating.

16
New cards

Critical Loading

A transmission equipment loading state operating between 90%90\% and 100%100\% of its rating.

17
New cards

Red Alert

A notice issued under the Philippine Grid Code when the system contingency reserve has dropped to zero.

18
New cards

Yellow Alert

A notice issued under the Philippine Grid Code when the system contingency reserve is low.

19
New cards

Pelton Turbine

A type of impulse hydro turbine selected specifically for high-head installations.

20
New cards

Kaplan Turbine

A type of reaction hydro turbine selected for low-head and large water flow applications.

21
New cards

Hydro Power Station

A type of generating station characterized by having the minimum running and fuel costs.

22
New cards

High-Speed Steam Turbo-Alternator Poles

The standard pole configuration consisting of 2 poles2\,\text{poles}.

23
New cards

Synchronous Speed Formula

The mathematical relationship for an AC machine given by Ns=120fPN_s = \frac{120f}{P}.

24
New cards

Operating Rotor Speed Formula

The equation determining induction rotor speed from synchronous speed NsN_s and slip ss, given by Nr=Ns×(1−s)N_r = N_s \times (1 - s).

25
New cards

Open-Delta Bank Maximum Capacity

The maximum permissible load capacity of an open-delta (V-V) transformer bank, equal to 1.732×kVA of one transformer1.732 \times \text{kVA of one transformer}.

26
New cards

Joule (Erg Equivalence)

The metric unit of energy equivalent to 107 ergs10^7\,\text{ergs}.

27
New cards

Mechanical Equivalent of Heat (Metric)

The conversion factor relating mechanical work to thermal energy in metric units, equal to 4.186 kJ/kcal4.186\,\text{kJ/kcal}.

28
New cards

Mechanical Equivalent of Heat (English)

The conversion factor relating mechanical work to thermal energy in English units, equal to 778.16 ft-lb/BTU778.16\,\text{ft-lb/BTU}.

29
New cards

Circular Mil Conductor Area

The cross-sectional area in circular mils calculated from diameter dd in mils using the formula A=d2A = d^2.

30
New cards

Square Mils to Circular Mils Conversion Formula

The relationship used to convert square mils into circular mils, defined as ACM=(4π)×Asq_milsA_{\text{CM}} = \left(\frac{4}{\pi}\right) \times A_{\text{sq\_mils}}.

31
New cards

Wire Resistance Multiplier (Doubled Length)

The resistance increases by a factor of 4 times4\,\text{times} when a wire is stretched to double its original length.

32
New cards

Wire Resistance Multiplier (Tripled Length)

The resistance increases by a factor of 9 times9\,\text{times} when a wire is drawn to triple its original length.

33
New cards

Standard Resistivity of Annealed Copper (20 ∘C20\,^\circ\text{C})

The standard electrical resistivity of annealed copper at 20 ∘C20\,^\circ\text{C}, equal to 10.37 Ω-cmil/ft10.37\,\Omega\text{-cmil/ft}.

34
New cards

Inferred Absolute Zero Temperature of Annealed Copper

The inferred temperature at which the resistance of annealed copper extrapolates to zero, equal to −234.5 ∘C-234.5\,^\circ\text{C}.

35
New cards

Inferred Absolute Zero Temperature of Aluminum

The inferred temperature at which the resistance of aluminum extrapolates to zero, equal to −236 ∘C-236\,^\circ\text{C}.

36
New cards

Manganin

An electrical alloy known for possessing a nearly zero temperature coefficient of resistance.

37
New cards

Nichrome

A high-resistivity alloy composed of nickel and chromium commonly used in heating elements.

38
New cards

Maximum Power Transfer Efficiency

The percentage efficiency of power transfer occurring under the maximum power transfer condition, which is exactly 50%50\%.

39
New cards

Maximum Power Transfer Condition

The resistance relationship required for maximum power delivery from a DC source to a load resistor, defined as Rload=RsourceR_{\text{load}} = R_{\text{source}}.

40
New cards

Maximum Transferred Power Formula

The expression computing peak power transfer using Thévenin parameters: Pmax⁡=Vth24×RthP_{\max} = \frac{V_{\text{th}}^2}{4 \times R_{\text{th}}}.

41
New cards

Ideal Constant Voltage Source Internal Resistance

The internal resistance of a theoretically ideal constant voltage source, which is 0 Ω0\,\Omega (zero ohms).

42
New cards

Ideal Constant Current Source Internal Resistance

The internal resistance of a theoretically ideal constant current source, which is infinite ohms (∞ Ω\infty\,\Omega).

43
New cards

Independent Voltage Source Deactivation

The method of replacing an independent voltage source with a short circuit when applying the Superposition Theorem.

44
New cards

Independent Current Source Deactivation

The method of replacing an independent current source with an open circuit when applying the Superposition Theorem.

45
New cards

Ampere-Hour Efficiency

The ratio of ampere-hour output delivered during battery discharge to the ampere-hour input supplied during recharge.

46
New cards

Absolute Permittivity of Free Space (ε0\varepsilon_0)

The physical constant representing the dielectric permittivity of a vacuum, equal to 8.854×10−12 F/m8.854 \times 10^{-12}\,\text{F/m}.

47
New cards

Relative Permittivity of Free Space

The dimensionless relative permittivity value assigned to a vacuum or free space, which is exactly 11.

48
New cards

Capacitor Electrostatic Stored Energy

The energy stored in the electrostatic field of a charged capacitor, given by W=0.5×C×V2W = 0.5 \times C \times V^2.

49
New cards

RC Circuit Time Constant

The characteristic response time of a series resistor-capacitor circuit, determined by τ=R×C\tau = R \times C.

50
New cards

Elastance

The electrical parameter defined as the reciprocal of capacitance (S=1CS = \frac{1}{C}).