DNA sequencing
direct determination of the order of nucleotides in a DNA polymer
most specific and direct method for identifying genetic lesions
two types of sequencing methods develop in the 1970s
Maxam-Gilbert sequencing
Sanger sequencing
Maxam-Gilbert (chemical) sequencing
required ds or ss version of DNA region to be sequenced w/ one end radioactively labeled
this labeled template aliquoted into four tubes
each tube treated w/ different chemical w/ or w/o high salt
addition of strong reducing agent, 10% piperidine, the ssDNA would break at specific nucleotides
reading Maxam-Gilbert sequence
lane in which that band appeared identified the nucleotide, reading from bottom of gel to top
Maxam-Gilbert sequencing: chain breaks at G
base modifier: dimethylsulphate (DMS)
methylates G
Maxam-Gilbert sequencing: chain breaks at G + A
base modifier: formic acid (FA)
protenates purines
Maxam-Gilbert sequencing: chain breaks at T + C
base modifier: hydrazine (H)
splits pyrimidine rings
Maxam-Gilbert sequencing: chain breaks at C
base modifier: hydrazine + salt (H + S)
(salt changes specificity)
splits only C rings
dideoxy chain termination (Sanger) sequencing
modification of DNA replication process
short, synthetic, ssDNA primer complementary to sequences just 5’ to region of DNA to be sequenced is used
basis of Sanger sequencing
primer covalently attached to a ³²P-labeled nucleotide or fluorescent dye-labeled nucleotide (visualization)
in vitro DNA replication occurs to make full length copies of DNA template
for sequencing, modified dideoxynucleotide (ddNTP) derivatives are added to the rxn
dideoxynucleotide (ddNTP) derivatives
lack the -OH group on the 3’ ribose, stopping DNA elongation when ddNTP is added
Sanger sequencing procedure
1:1 mix of templates and labeled primer placed into 4 rxn tubes
each tube has same ingredients for PCR rxn
mixtures of all four dNTPs, and one of the four ddNTPS (A, T, C, or G) are then added to each tube
add DNA pol, after 20 min terminate the rxn by adding stop buffer
sets of synthesized fragments are resolved in a gel - sequencing ladder
Sanger sequencing tube components
ddATP + four dNTPs
ddCTP + four dNTPs
etc
what does dideoxynucleotide do?
terminates chain
Sanger sequencing - sequencing ladder
ladder read from bottom to top
smallest fragment represents first nucleotide attached to primer
band formed each interval when elongation stopped, at corresponding ddNPT in tube
automated Sanger sequencing
use fluorescent dyes instead of radioactive label
two approaches: dye primer and dye terminator
label the fragments synthesized during sequencing according to their terminal ddNTP
fragments resolved by capillary electrophoresis
detector will read the fluorescence corresponding to each ddNTP as these pass through capillary
terminal ddATP color
green
terminal ddCTP color
blue
terminal ddGTP
yellow or black
terminal ddTTP color
red
for automated Sanger sequencing, the color of the dye corresponds to what?
the ddNTP that terminated the strand
resolving fragments by capillary electrophoresis during Sanger sequencing
shorter fragments (closer to the primer) will migrate faster than longer ones
detection in automated Sanger sequencing
as fragments pass through capillary, laser excites terminator dye and signal is detected
software reads or “calls” these bases from smallest fragments to largest
compiles these signals creating an electropherogram
electropherogram
series of peaks, one for each of the 4 fluorescent dyes
a chart of light emission over time
how many bp are used to sequence on an electropherogram?
400 - 800 bp
X and Y-axis on electropherogram
Y-axis: intensity
X-axis: scan numbers
electropherogram - interpretation using base calling
process of identification of bases in a sequence by sequencing software
when base call is not clear, letter N will replace the nucleotide
beginning of chart: messy peaks, sequences before 30 bp are not reliable
what do the grey bars on an electropherogram indicate?
Q-value, which indicates the probability of correct call; anything >20 is acceptable
electropherogram - end interpretation at end of run
can get up to 1,000 reliable bases
will see peak quality begin to degrade, Q-value drops below acceptability
electropherogram - DNA contamination
presence of dye blobs - bright flashes of fluorescence that shows as large broad peaks
combination of short and large peaks indicates low DNA concentration and contamination
electropherogram - no DNA at all
no template shows as random noise
peaks are very short (~50 intensity units) indicating that there is no DNA
electropherogram - too much DNA
represented by very high intensity peaks at beginning of run. then, quickly drop
electropherogram - heterozygous mutations
software can compare two sequences to identify mutations
heterozygous mutations are observed as double peaks in affected bp
must be confirmed by running the reverse sequence
electropherogram - heterozygous deletions or insertions
InDels (insertions or deletions) affect all positions of sequence downstream of mutation
overlaid sequences will show minus bases if a deletion
application of automated Sanger sequencing
microbial, plasmid, targeted DNA, mitochondrial, HLA sequencing
validation of sequencing
gene expression analysis