Steam sterilization
Most effective, preferred choice if product can stay intact
Requires lower temperature than dry heat ~121C vs 170C
Bacteria coagulated and destroyed at lower temperature in the presence of moisture than in the absence of moisture
121C for 20 minutes
When can steam sterilization be used
Aqeuous solutions
Sealed empty vials with small quantity of water inside
Bulk solutions
Glassware
Surgical dressings
Surgical instruments
When is steam sterilization not applicable
Oils
Fats
Materials not penetrated by moisture
Exposed powders that may be damaged by condensed moisture
Sterilization for suspensions and emulsions
Steam sterilization is preferred if the product can withstand it
Autoclaving can affect viscosity, suspend ability and particle size of the product
Can break/destroy the suspension or emulsion
Components may be sterilized individually before combining
Dry heat sterilization
Thermostatically controlled ovens
Dehydrate microorganisms
Less effective than steam
Higher temp for longer periods of time (150-170C for no less than 2 hours)
When can dry heat sterilization be used
Non-aqueous solutions (oil)
Heat stable dry powders
Dry containers
Glassware
Surgical instruments
Sterilization by filtration
Physical removal of microorganisms by absorption on the filter medium or by sieving microorganisms
Used for heat sensitive solutions
Filter pore sizes range: 0.025-14 um
Can use nylon, cellulose acetate, cellulose nitrate, PVC, polyester
Fast filtration of small quantities of solution is relatively inexpensive
Complete removal of dead or living organisms
Applicable in hospitals for small volumes
Difficult for viscous materials, drug can be removed
Gas sterilization
By exposure to ethylene oxide or propylene oxide
Highly flammable - should be mixed with inert gases
Requires specialized equipment
Enhanced by humidity and elevated temp at 50-60C
4-16 hours
Interferes with bacteria metabolism
Gas can penetrate plastic bags
For heat sensitive and moisture sensitive materials
Can remove enzymes and certain bacteria
Sterilization by ionizing radiation
Gamma rays and cathode rays
Destruction of cells by radiation
Limited because of specialized equipment needed and effect of radiation on the product and container
may denature the product
Validation of sterility
Testing to confirm the absence of microorganisms
Biological indicators
A characterized preparation of specific microorganisms resistant to a particular sterilization process. Used to monitor sterilization process, revalidate process. Spores can be added to allow sterilization of act as a representative unit of product being sterilized.
D value
Decimal reduction time. Time required to achieve one log (90%) reduction in microbial population at a sterilization temperature.
Z value
The increase in temperature for steam (under pressure) or dry heat sterilization or the dose of radiation sterilization required to produce one log (90%) reduction in the D value for particular microorganisms
F value
Time required to kill a known population of microorganisms under specified condition. Can be used to compare the lethality of different heat sterilization processes.
Ft equation
Ft = Dt (logA - logB)
Dt= the time for one log reduction in microbial population at temperature T
A = initial population
B = population after a defined time
Sterility Assurance Level
The degree of assurance for a sterilizing process to render a population of products sterile. SAL of 10-6 or better is required.
Inactivation factor
Measures the reduction in the number of microorganisms of a known D value brought about by a defined sterilization process
IF equation
IF = A/B = 10t/D
t is contact time with heat or radiation dose
D is the D value appropriate to the process employed
Assumed bacterial inactivation is a first order process
Endotoxins
Are a subset of pyrogens that come from gram negative bacteria
Natural complex of LPS occurring in the outer cell wall of bacteria
Cause fever, irreversible fatal septic shock, hypotension, lymphopenia, neutrophilia, elevated cortisol
They are water soluble and thermostable
Endotoxin elimination
Can be precipitated using potassium permanganate, bactrium hydroxide, followed by distillation in water
Can be eliminated by dry heat 210C for 3-4 hours
or
250C for 30 minutes
650C for 60 seconds
EL
Tolerable endotoxin load per dose
EL equation
EL = K/M
K- threshold of human pyrogenic dose of endotoxin per kg of body weight per hours
M - maximum recommended human dose per kg of body weight that would be administered in a single 1 hour period
Pyrogen testing
A regulatory requirement for release of sterile parenteral drugs
Rabbit pyrogen testing
Measuring rise in temperature of rabbits following IV injection of tested product
Low sensitivity and poor robustness
Limulus Amebocyte lysate test
An extract from RBCs of horseshoe crab contains an enzyme and protein system that coagulates in the presence of low levels of LPS
More heat sensitive
Packaging of parenteral products
Containers cannot interact with preparation
Containers must allow inspection of the components
Single dose containers
A hermetic container holding a quantity of sterile drug intended for parenteral administration as a single dose
When opened it cannot be resealed
Ampules or single dose vials
Multiple dose containers
A hermetic container that permits withdrawal of successive portions of the contents without changing the strength, quality, or purity
Vials or bags