1/53
Flashcards covering core terminology and concepts from the Electrical Technology Reviewer, including AC generation, conductor color coding, testing instruments, protective devices, transformer equations, and three-phase motor principles.
Electric Generator
A device that converts mechanical energy into electrical energy through electromagnetic induction.
Electromagnetic Induction
The production of voltage when a conductor experiences a changing magnetic field.
Magnetic Field
An area where magnetic forces act.
Electric Current
The flow of electric charge.
Slip Rings
Components in an AC generator that maintain electrical connection between the rotating coil and the external circuit.
Commutator
A device in a DC generator that reverses the coil connections every half-turn, keeping the external current flowing in one direction.
Conventional Current Flow
The flow of electric current directed from positive to negative.
Electron Flow
Also called true current flow; the flow of electrons directed from negative to positive.
Right-Hand Rule
A rule used to determine the direction of the magnetic field around a current-carrying conductor, where the thumb points in the direction of conventional current and the fingers indicate the direction of the magnetic field.
Left-Hand Rule
A rule used to determine the magnetic field direction around a conductor based on electron flow.
Fleming's Left-Hand Rule
A rule used to determine the direction of force or motion on a current-carrying conductor placed in a magnetic field.
Electrical Insulation
A nonconductive covering that prevents unwanted current flow, avoids short circuits by keeping conductors separated, and protects against electric shock.
Resistivity
A material's opposition to the flow of electric current; materials with high resistivity strongly resist current flow and make suitable insulators.
Electrical Cable
An assembly of one or more insulated conductors enclosed within a protective covering or sheath.
Line Conductors (Philippines Color Code)
Conductors identified by the colors black, blue, red, or orange.
Neutral Conductor Color
Identified by the color white.
Grounding Conductor Identification
Identified by the colors green, green with yellow stripes, or by bare copper.
Megger
An electrical testing instrument that measures insulation resistance; a low reading indicates damaged or deteriorated insulation.
Multimeter (VOM)
A test instrument commonly called a volt-ohm-milliammeter that measures voltage in volts (V), resistance in ohms (Ω), and current in amperes (A).
Analog Multimeter
A meter that displays readings with a moving pointer on a graduated scale, making changes in readings easy to observe.
Digital Multimeter
A meter that displays measured electrical quantities as numerical values on a digital screen.
Clamp Meter
A measuring instrument that detects current via jaws sensing the magnetic field around one conductor only, without direct electrical connection.
Fuse
A circuit protective device containing an element that melts and interrupts current when excessive current flows through it.
Circuit Breaker
A protective device that automatically opens a circuit during an overload or short circuit and can be reset once the fault is corrected.
PolySwitch
A resettable fuse designed to protect electrical circuits against overcurrent.
Residual Current Circuit Breaker (RCCB)
Also called a Residual Current Device (RCD); a safety device that helps reduce electric shock caused by earth-leakage current.
Inrush Current
The brief, high surge of current drawn when electrical equipment is first switched on.
Inrush Current Limiter
A protective component that reduces the initial surge of current when equipment is powered on.
Metal-Oxide Varistor (MOV)
A voltage-dependent resistor (VDR) whose resistance changes depending on the applied voltage.
Gas Discharge Tube
A surge-protection device that diverts high-voltage surges by conducting and directing surge current away from protected equipment.
Lightning Arrester
A protective device that safeguards electrical equipment by providing a path for lightning surges to travel safely to ground.
Thermal Overload Relay
A protective relay designed to safeguard motors against overload and overheating caused by excessive current.
Magnetic Relay
An electromechanical switch operated by an electric current energizing a coil to create a magnetic field that moves an armature and alters contacts.
Electronic Motor Protection Relay
A device that monitors motor conditions and trips the circuit when faults such as overload, phase loss, or imbalance occur.
Reverse Power Relay
A relay used on generators to prevent them from acting as a motor when electrical power flows back into the machine.
Transformer
A device that transfers electrical energy between circuits through electromagnetic induction and changes AC voltage levels.
Mutual Induction
The production of voltage in one coil when the changing current in a nearby coil changes the magnetic flux linking it.
Primary Winding
The transformer coil that receives electrical energy from the AC input source.
Secondary Winding
The transformer coil that delivers transformed voltage to the load.
Step-Up Transformer
A transformer that increases voltage from the primary winding to the secondary winding.
Step-Down Transformer
A transformer that decreases voltage from the primary winding to the secondary winding, having fewer turns on the secondary than on the primary.
Turns-Ratio Formula
The transformer voltage and winding relationship given by VsVp=NsNp, which rearranges to solve for secondary turns as Ns=VpNp×Vs.
Ideal Transformer Power Equation
The principle stating that input power equals output power with zero energy loss: Vp×Ip=Vs×Is.
Three-Phase Electrical System
An AC power system producing three alternating waveforms of the same frequency separated by equal phase angles of 120 electrical degrees.
Delta Connection (Δ)
A three-phase wiring configuration normally using three line wires, where VL=Vph and IL=13×Iph.
Wye Connection (Y / Star)
A three-phase wiring configuration that can use four wires (three line wires and one neutral), where VL=3×Vph and IL=Iph.
Apparent Power (S)
The total power in a three-phase circuit calculated as S=3×VL×IL with units in volt-amperes (VA).
Active Power (P)
The real power delivered in a three-phase circuit expressed as P=3×VL×IL×power factor with units in watts (W).
Reactive Power (Q)
The power that oscillates between source and load in a three-phase system, calculated as Q=3×VL×IL×sin(θ) with units in vars (var).
Power Factor (PF)
The ratio of real power to apparent power represented by PF=SP=cos(θ), indicating how effectively electrical power is utilized.
Field Magnet
A key motor part that produces the magnetic field required for motor operation.
Armature Core
The part of an electric motor that mechanically supports the armature coil and provides a low-reluctance path for magnetic flux.
Armature Coil
The winding in an electric motor that carries current and interacts with the magnetic field to produce torque.
Motor Brushes
Conductive components that transfer electric current between the stationary external circuit and the rotating commutator of a motor.