Intro to Agricultural Mechanization and Farm Structures

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/30

encourage image

There's no tags or description

Looks like no tags are added yet.

31 Terms

1
New cards
Perspective Drawings
Single-view pictorial drawings that attempt to present an accurate visual representation of an object's realistic appearance, where distant objects recede in size.
2
New cards
Isometric Drawings
Pictorial drawings where two sides and the roof are visible simultaneously, horizontal edges are oriented at a 30∘30^\circ angle to the horizontal base line, and vertical lines remain strictly vertical.
3
New cards
Oblique Drawings
Pictorial drawings featuring one vertical axis, one horizontal axis, and one axis oriented at a 30∘30^\circ angle to the horizontal.
4
New cards
Working Drawings
Explicit technical specifications providing separate orthogonal views (top, side elevation, front elevation) drawn precisely to scale.
5
New cards
Board Foot
A volume equivalent to a square foot of lumber 1 inch1\,\text{inch} thick (12′′×12′′×1′′12'' \times 12'' \times 1'' nominal), calculated as Board Feet=T×W×L×N12\text{Board Feet} = \frac{T \times W \times L \times N}{12}.
6
New cards
U-value
A measurement of thermal conductivity representing the heat flow rate in Btu/hr\text{Btu/hr} per square foot of area per 1∘F1^\circ\text{F} temperature difference across sides.
7
New cards
R-value
A measurement of thermal resistance defined mathematically as the inverse of U-value (R=1UR = \frac{1}{U}).
8
New cards
Continuous Vapor Barrier
A moisture-control layer installed on the warm/interior side of wall, ceiling, and floor assemblies to prevent condensation from freezing inside insulation.
9
New cards
Square (Roofing)
A unit of roof area measurement equivalent to 100 sq ft100\,\text{sq ft}.
10
New cards
White Rust
Zinc carbonate formed when trapped moisture accumulates between flat-stacked galvanized steel sheets, rapidly destroying the protective coating.
11
New cards

Dry-Bulb Temperature

The temperature of ambient air measured using a standard thermometer in degrees Fahrenheit (∘F^\circ\text{F}).

12
New cards

Relative Humidity

The ratio of water vapor present in the air relative to the maximum amount the air can hold at the same temperature, expressed as a percentage.

13
New cards

Dew Point

The temperature at which water vapor in the air begins to condense into liquid droplets.

14
New cards

British Thermal Unit (Btu)

The quantity of heat energy required to raise the temperature of 1 lb1\,\text{lb} of water from 60∘F60^\circ\text{F} to 61∘F61^\circ\text{F}.

15
New cards

Conduction

The transfer of heat energy between contacting bodies or through materials, representing the primary mode of structural heat loss.

16
New cards

Dimension Lumber

Wood nominally 2 inches2\text{ inches} or thicker, planed on all four sides (S4S), and used for principal structural framing such as joists, studs, and rafters.

17
New cards

Dead Load

The permanent vertical downward force acting on a structure caused by the self-weight of its construction materials.

18
New cards

Live Load

Transient or variable forces applied to a structure, including snow accumulation, wind pressures, animals, and stored agricultural products.

19
New cards

Tensile Stress

An internal structural stress that acts to pull a material or structural element apart.

20
New cards

Compressive Stress

An internal structural stress that acts to press or squeeze a material or structural element together.

21
New cards

Shear Stress

An internal structural stress that acts to slide adjacent internal layers of a material relative to one another.

22
New cards

Cantilever Beam

A structural beam anchored solidly at one end while the opposite end remains completely free and unsupported.

23
New cards

Extension Lines

Drafting lines drawn with a 116 inch\frac{1}{16}\,\text{inch} gap from object edges to define the limits of dimension lines.

24
New cards

Common Boards

Lumber less than 2 inches2\,\text{inches} in nominal thickness (commonly 1 inch1\,\text{inch} nominal, planed to an actual thickness of 2532 inch\frac{25}{32}\,\text{inch}) used for general non-structural applications.

25
New cards

Finish Lumber

Select high-quality lumber that contains no surface defects that cannot be completely concealed by paint, rarely used in utilitarian farm structures.

26
New cards

Pattern Lumber

Lumber precision-machined into specialized architectural profiles, such as Shiplap, Bevel Siding, Drop Siding, and Tongue & Groove.

27
New cards

Simple Beam

A structural member supported at both ends without a rigid connection, allowing free rotation at its end supports.

28
New cards

Continuous Beam

A structural member that extends continuously across three or more support points.

29
New cards

Horizontal Air Flow (HAF) Fans

Small circulation fans mounted above crops that move air in circular patterns to improve temperature uniformity across a greenhouse.

30
New cards

Evaporative Fan-and-Pad Systems

Active mechanical cooling systems where exhaust fans pull air through wet cellulose pads, absorbing ambient heat as water evaporates.

31
New cards

Asphalt Shingle Slope Requirement

A minimum roof slope of 4 inches per foot4\,\text{inches per foot} of rise (16\frac{1}{6} pitch) required for standard asphalt shingle installations.