1/30
Looks like no tags are added yet.
Dry-Bulb Temperature
The temperature of ambient air measured using a standard thermometer in degrees Fahrenheit (∘F).
Relative Humidity
The ratio of water vapor present in the air relative to the maximum amount the air can hold at the same temperature, expressed as a percentage.
Dew Point
The temperature at which water vapor in the air begins to condense into liquid droplets.
British Thermal Unit (Btu)
The quantity of heat energy required to raise the temperature of 1lb of water from 60∘F to 61∘F.
Conduction
The transfer of heat energy between contacting bodies or through materials, representing the primary mode of structural heat loss.
Dimension Lumber
Wood nominally 2 inches or thicker, planed on all four sides (S4S), and used for principal structural framing such as joists, studs, and rafters.
Dead Load
The permanent vertical downward force acting on a structure caused by the self-weight of its construction materials.
Live Load
Transient or variable forces applied to a structure, including snow accumulation, wind pressures, animals, and stored agricultural products.
Tensile Stress
An internal structural stress that acts to pull a material or structural element apart.
Compressive Stress
An internal structural stress that acts to press or squeeze a material or structural element together.
Shear Stress
An internal structural stress that acts to slide adjacent internal layers of a material relative to one another.
Cantilever Beam
A structural beam anchored solidly at one end while the opposite end remains completely free and unsupported.
Extension Lines
Drafting lines drawn with a 161inch gap from object edges to define the limits of dimension lines.
Common Boards
Lumber less than 2inches in nominal thickness (commonly 1inch nominal, planed to an actual thickness of 3225inch) used for general non-structural applications.
Finish Lumber
Select high-quality lumber that contains no surface defects that cannot be completely concealed by paint, rarely used in utilitarian farm structures.
Pattern Lumber
Lumber precision-machined into specialized architectural profiles, such as Shiplap, Bevel Siding, Drop Siding, and Tongue & Groove.
Simple Beam
A structural member supported at both ends without a rigid connection, allowing free rotation at its end supports.
Continuous Beam
A structural member that extends continuously across three or more support points.
Horizontal Air Flow (HAF) Fans
Small circulation fans mounted above crops that move air in circular patterns to improve temperature uniformity across a greenhouse.
Evaporative Fan-and-Pad Systems
Active mechanical cooling systems where exhaust fans pull air through wet cellulose pads, absorbing ambient heat as water evaporates.
Asphalt Shingle Slope Requirement
A minimum roof slope of 4inches per foot of rise (61 pitch) required for standard asphalt shingle installations.