1
New cards
What are the three components of inherent filtration?
Glass window of the x-ray tube, insulating oil, and tubehead seal.
2
New cards
What is added filtration?
Aluminum discs added to the x-ray tubehead to filter radiation.
3
New cards
How much filtration does each aluminum disc provide?
0.5 mm.
4
New cards
According to the lecture, what is the required total filtration for lower kVp machines?
1.5 mm aluminum equivalent.
5
New cards
According to the lecture, what is the required total filtration for higher kVp machines?
2.5 mm aluminum equivalent.
6
New cards
What does filtration remove from the x-ray beam?
Long-wavelength, low-energy x-rays.
7
New cards
What happens to the average penetrating power of the x-ray beam after filtration?
It increases.
8
New cards
What is collimation?
Restricting the size and shape of the x-ray beam.
9
New cards
What is a collimator made of?
A lead plate with an opening for the x-ray beam.
10
New cards
What is rectangular collimation?
A rectangular opening slightly larger than the image receptor.
11
New cards
What is circular collimation?
A round opening that produces a circular x-ray beam.
12
New cards
What is the diameter of a circular collimator according to the lecture?
2.75 inches.
13
New cards
Which collimator reduces unnecessary radiation exposure more effectively?
Rectangular collimator.
14
New cards
What are the three types of position-indicating devices (PIDs)?
Conical, rectangular, and round.
15
New cards
Why are conical PIDs no longer used?
They cause too much scattered radiation.
16
New cards
What are the two common PID lengths?
8 inches and 16 inches.
17
New cards
Which PID length is preferred?
16 inches (long PID).
18
New cards
Why is a long PID preferred?
It reduces beam divergence.
19
New cards
What is the purpose of a thyroid collar?
To protect the thyroid gland from radiation.
20
New cards
Why is a thyroid collar not used during panoramic radiographs?
It can interfere with the image.
21
New cards
What is the purpose of a lead apron
To shield the torso, reproductive organs, and blood-forming tissues.
22
New cards
What is the minimum lead equivalence of a protective apron according to the lecture?
Greater than 0.25 mm.
23
New cards
What is the most effective method of reducing patient radiation exposure according to the lecture?
Using faster film speed.
24
New cards
What two film speeds are mentioned in the lecture?
D-speed and F-speed.
25
New cards
How much faster is F-speed film than D-speed film?
60% faster.
26
New cards
How much can digital sensors reduce exposure time compared with film?
50–80%.
27
New cards
What six methods help protect patients from excess radiation during exposure?
Thyroid collar, lead apron, fast film or digital sensors, beam alignment devices, proper exposure settings, and proper technique.
28
New cards
What is the purpose of a beam alignment device?
To hold the receptor, allow paralleling, and align the PID correctly.
29
New cards
What kVp range minimizes patient exposure according to the lecture?
60–80 kVp.
30
New cards
What mA range is mentioned in the lecture?
6–8 mA.
31
New cards
Why is proper radiographic technique important?
It produces a diagnostic image the first time and prevents unnecessary retakes.
32
New cards
Why is proper film or sensor handling important?
To obtain diagnostic-quality images.
33
New cards
Why is proper film processing important?
To maintain diagnostic image quality.
34
New cards
Why is proper image storage important?
To preserve diagnostic images.
35
New cards
Why is proper mounting important?
To prevent errors and unnecessary retakes.
36
New cards
How far should an operator stand from the x-ray tubehead during exposure?
At least 6 feet away, or behind a protective barrier.
37
New cards
Where should an operator stand during x-ray exposure?
Behind a lead barrier or off to the side, outside the primary beam.
38
New cards
Should an operator ever stand in the path of the primary x-ray beam?
No.
39
New cards
Should an operator hold the receptor in the patient's mouth during exposure?
No, never.
40
New cards
Should an operator hold the tubehead during exposure?
No, never.
41
New cards
What three types of radiation are identified in the operator protection section?
Primary radiation, leakage radiation, and scattered radiation.
42
New cards
What is equipment monitoring?
Checking x-ray machines for radiation leakage through mandatory inspections.
43
New cards
What is personnel monitoring?
Monitoring the radiation exposure received by workers.
44
New cards
What device is used for personnel monitoring?
A dosimeter badge.
45
New cards
Are personnel monitoring badges commonly used according to the lecture?
No, not commonly.
46
New cards
What does ALARA stand for?
As Low As Reasonably Achievable.
47
New cards
What is the purpose of ALARA?
To keep radiation exposure as low as reasonably achievable for patients and workers.
48
New cards
What federal law standardized x-ray equipment?
Radiation Control for Health and Safety Act of 1968.
49
New cards
What does Indiana require for dental radiography operators according to the lecture?
Licensure.
50
New cards
What does MPD stand for?
Maximum Permissible Dose.
51
New cards
What is MPD?
The maximum yearly radiation dose a person may receive with little or no expected injury, according to the lecture.
52
New cards
Which organization defines MPD?
National Council on Radiation Protection and Measurements (NCRP).
53
New cards
What is the annual occupational MPD according to the lecture?
5 rem, 0.05 Sv, or 50 mSv.
54
New cards
What is the annual MPD for the general public according to the lecture?
0.1 rem, 0.001 Sv, or 1 mSv.
55
New cards
What is the monthly MPD during pregnancy according to the lecture?
0.05 rem, 0.0005 Sv, or 0.5 mSv.
56
New cards
What does MAD stand for?
Maximum Accumulated Dose.
57
New cards
What is the older formula for MAD?
(N − 18) × MPD.
58
New cards
What does N represent in the MAD formula?
The person's current age.
59
New cards
What does COD stand for?
Cumulative Occupational Dose.
60
New cards
What is the current COD formula according to the lecture?
Age × 10 mSv.
61
New cards
What is the COD for a 50-year-old hygienist?
500 mSv or 0.5 Sv.
62
New cards
What radiation protection steps should be taken BEFORE exposure?
Prescribe only necessary radiographs, use filtration, and use proper collimation.
63
New cards
What radiation protection steps should be taken DURING exposure?
Use patient shielding as taught, fast receptors, beam alignment devices, correct exposure settings, and proper technique.
64
New cards
What radiation protection steps should be taken AFTER exposure?
Properly handle, process, store, and mount radiographs to prevent unnecessary retakes.
65
New cards
How should dental professionals educate patients about radiation exposure?
Explain precautions, answer questions, acknowledge risks, and discuss benefits.
66
New cards
When should dental radiographs be prescribed?
Only when necessary based on the individual patient's needs.
67
New cards
Should radiographs be retaken just to improve a grade?
No.