1
New cards

Carbon footprint is the;

amount of carbon dioxide that is produced from a process

2
New cards

What can be used to predict the effects of energy conservation measures used in a building?

Building information modeling

3
New cards

When selecting residential energy upgrades, the concept of cost versus benefits is referred to as;

saving to investment

4
New cards

What best represents the part of a structure that is in contact with both the conditioned and unconditioned spaces?

Building envelope

5
New cards

Renewable energy is;

A repeatable source of energy

6
New cards

Sustainable energy is defined as a;

Source of energy that has no effect or impact on current or future resources

7
New cards

What test is used to diagnose and measure a building’s air tightness and help locate air leaks?

Blower door

8
New cards

Effective energy conservation measures can be determined by;

conducting an energy audit

9
New cards

The Energy Information Administration;

Supplies energy usage data

10
New cards

An energy audit is;

a collective inspection, survey, and analysis of a structure

11
New cards

Which of the following is an energy conservation measure?

Replacing all long life incandescent bulbs to LED bulbs

12
New cards

Conducting a blower door test to quantify air leakage rates is a test to determine the air infiltration and heat transfer energy losses after which process?

Energy audit

13
New cards

Energy managers can detect potential energy problems by;

constant analysis and documentation

14
New cards

The electrical “Demand” rate for commercial enterprises can be reduced by;

reducing power consumption during peak periods

15
New cards

A heat load calculation for a residential home is based on the;

indoor design and outdoor design temperatures

16
New cards

In an effort to reduce the energy usage in a building, which four construction techniques play an integral role?

Initial home design, insulation, appliances, and lighting

17
New cards

Life Cycle Assessment or Life Cycle Cost Analysis is the;

total cost of purchasing, operating, and maintaining equipment

18
New cards

What can be done to increase overall energy efficiency in a building?

establish and implement maintenance procedures and policies for all mechanical systemsW

19
New cards

What is R-value

It is the thermal resistance of a material based on a thickness and density

20
New cards

Ethanol is a renewable energy source because it is produced through the;

distillation of crops

21
New cards

What term is considered the process which estimates and evaluates the life cycle cost over the life expectancy of raw materials from the point at which they are compiled, until the time when they are returned back to the earth?

Cradle-to-grave

22
New cards

What is fenestration?

Any area which allows light to pass through an external wall of a building

23
New cards

In order to determine the required capacity of heating or cooling equipment for a structure;

a “Heat Load Calculation” should be performed

24
New cards

In the life cycle assessment, what process is the continued use and reuse of a product that has little or no environment impact?

Cradle-to-cradle

25
New cards

Which of the following is a source of sustainable energy?

Ethanol

26
New cards

A measure of the relative efficiency of a room air conditioner appliance is;

Energy Efficient Ratio (EER)

27
New cards

Which of the following is used to rate a central cooling system?

Seasonal Energy Efficiency Ratio (SEER)

28
New cards

Which of the following is a rating of how efficiently a furnace consumes fuel over the entire heating season?

Annual Fuel Utilization Efficiency (AFUE)

29
New cards

Heating Season Performance Factor is used as an energy rating for;

heat pumps

30
New cards

The standard temperature used to calculate COP (Coefficient of Performance) for an air to air heat pump is;

47F and 17F outdoor temperature

31
New cards

Heating and cooling efficiency ratings such as SEER, EER, COP, and HSPF are regulated by;

Air Conditioning, Heating, Refrigeration Institute (AHRI)

32
New cards

The Coefficient of Performance (COP);

varies based on outdoor temperature

33
New cards

HSPF air source heat pump equipment ratings range from;

8 to 12

34
New cards

In order to maintain an acceptable indoor air quality in tight structures, ventilation standards were established by;

American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE)

35
New cards

Mechanical vapor compression air conditioning systems;

Provide comfort, cooling, and dehumidification

36
New cards

Which of the following cooling systems work best in dry climates?

Evaporative

37
New cards

Passive cooling is;

A form of natural cooling from shading and directing outdoor air flow

38
New cards

Solar cooling may be accomplished by;

using solar energy to power an absorption system

39
New cards

Thermal storage is;

used to store energy for heating or cooling until needed

40
New cards

Systems that can have multiple indoor units connected to a single outdoor unit are known as;

Ductless mini-splits

41
New cards

HCFC-22 is;

an ozone depleting substance and a greenhouse gas

42
New cards

GreenChill is a cooperative alliance between;

Industry and the U.S. Environmental Protection Agency

43
New cards

A test performed to assure a fossil fuel system is operating as close to design specification is called;

combustion analysis

44
New cards

In forced air heating systems, the;

air is circulated over the surfaces of the heat exchanger where it absorbs heat

45
New cards

A fossil fuel modulating furnace varies its fuel input and blower motor speed;

using advanced control technology

46
New cards

A condensing boiler;

condenses moisture from the flue gases

47
New cards

An instantaneous boiler;

heats water to satisfy demand at a particular location and time

48
New cards

Waste-Heat Recovery systems can be adapted to air conditioning systems for;

water heating

49
New cards

Radiant heat transfers its energy when;

it contacts an object, such as a wall, desk, chair, or person

50
New cards

The type of system that uses the earth as both a heating and cooling medium is a;

geothermal system

51
New cards

What would be the annual operating cost of an appliance that uses 400 watts for 5 continuous hours per day if the current electrical rate is 10 cents per kilowatt

$73

52
New cards

The electrical energy efficiency of an appliance or device is determined by;

how well the device converts the electricity to useful work

53
New cards

A Green Alternative for producing massive amounts of electrical energy is;

photovoltaic cells

54
New cards

The difference between a nuclear power plant and a fossil fuel plant is;

the method used to heat the water to produce steam

55
New cards

The first fuel cell was designed in;

the year 1839

56
New cards

To produce the voltage necessary for a process;

Fuel cells can be stacked

57
New cards

Photovoltaic panels are used to power;

almost everything including street lighting, NASA satellite equipment, and even the grid

58
New cards

When photovoltaic modules are interconnected, they are called;

Solar photovoltaic array

59
New cards

The power generated by “Wind Turbines”

must be altered before it can be used by the grid

60
New cards

The term “Wind Farm” refers to the;

business of generating power for sale to the grid

61
New cards

“Tidal and Ocean Energy” is;

electrical power produced from ocean waves, tides, and currents

62
New cards

Unlike “Wind generators”, “Tidal generators” are;

predictable for power generation

63
New cards

Appliances such as computers, televisions, and most chargers when powered off continue to use electricity. These devices are known as;

ghost loads

64
New cards

The Electronic Commutated Motor (ECM);

has the highest efficiency ratings for air conditioning purposes

65
New cards

The ECM (Electronic Commutated Motor);

is a Direct Current (DC) brushless synchronous motor

66
New cards

Variable Frequency Drive (VFD) motors;

are typically used on most high efficiency commercial AC systems

67
New cards

Luminous efficacy is how efficient a lightbulb is at creating;

visible light versus heat

68
New cards

Historically, most lighting has been purchased based on the;

wattage of the bulb

69
New cards

A lumen is the;

amount of light on one square foot of surface created by a candle one foot away

70
New cards

High voltage transformers used in fluorescent lighting are called;

ballasts

71
New cards

Which control can be used to dim fluorescent lighting?

Electronic dimming ballasts

72
New cards

LED is the acronym for which of the following?

Light Emitting Diode

73
New cards

How long can flashlights that use LED’s be used continuously before new batteries are needed?

150 hours

74
New cards

Two major appliances in the home that use the most kW/H are the;

electrical water heater and the clothes drier

75
New cards

An appliance using 7500 watts of power continuously for 5 hours would use;

7.5 × 5 = 37.5 kilowatt hours

76
New cards

Of all the available water on the planet, how much is fresh water and also attainable?

0.3%

77
New cards

The 1992 Energy Policy Act passed requiring that showerheads and faucets were rated at 2.5 Gpm @;

80 psi

78
New cards

Showers can use as much as;

12% of the water used in a home

79
New cards

Pre-rinse spray valves are used in commercial kitchens to rinse the;

food containers before washing

80
New cards

A faucet water flow restriction device which adds air to the volume of water is the;

aerator

81
New cards

The 1992 Energy Policy Act set the standard for water closets (WCs) by reducing the amount of water for flushing to;

1.6 gallons

82
New cards

Water closets that reduce water used from 1.6 to 1.28 (gpf) are known as;

ultra low flush and dual flush fixtures

83
New cards

Dual flush water closets provide the user flushing options. These options are selected by;

two buttons on the tank lid or a dual section action of the handle

84
New cards

The 1992 Energy Policy Act urinal flush requirement uses;

1 gallon per flush

85
New cards

The removable cartridge is used with a;

waterless urinal

86
New cards

The cartridge free urinal is a;

waterless urinal

87
New cards

The composting toilet can be;

self-contained or with a remote tank

88
New cards

The Energy Star label when attached to a high efficiency plumbing appliance indicates that the;

energy/water needed for operation is 10-50% lower than a non Energy Star appliance

89
New cards

The Energy Star dishwasher uses approximately;

4 gallons of hot water per cycle

90
New cards

Energy Star rated air-cooled, cube-type ice machines are;

approximately 15% more energy efficient and use 10% less water than older models

91
New cards

Insulating the water heater and hot water piping is;

one of the easiest ways to make an immediate impact on energy savings

92
New cards

The on demand water circulation system;

delivers hot water immediately without the cold water waste period

93
New cards

The dedicated line water circulation system;

keeps the water in the hot water piping at a constant tempurature

94
New cards

The gravity water circulation system uses;

the natural tendency of hot water to rise and cooler water to fall

95
New cards

Water distribution piping installations include;

grouping fixtures closer together and using manifolds for water distribution

96
New cards

Water ‘hammer’ most commonly occures when;

the flow of moving water is suddenly stopped by a rapid closing valve

97
New cards

Conventional storage water heaters are the most common type of water heater installed. They consume an estimated;

10-25% of the energy used in an average home

98
New cards

Reclaim water is required by most codes to be run in;

purple pipe and identifies as “Reclaimed Water - Do Not Drink”

99
New cards

Industrial fire protection systems used Halon-1301 (EPA unfriendly gas) in water sensitive areas; in 1993 this substance was replaced with;

FM 200

100
New cards

The best method used for the irrigation of landscaping is;

in ground or drip systems