Standard P1 Water Capacity
The total volume of water a standard P1 appliance can carry, which is 1800litres.
Hose Reel Jet Run Time
The duration a hose reel jet operates at 20bar, lasting 20minutes individually or 10minutes if both are running.
Theoretical and Practical Lift
The lifting limits when pumping from open water: a theoretical lift of 10m and a practical lift of 8m.
Hierarchy of Water Rescue
The phased sequence of rescue methods consisting of: Talk, Reach, Throw, Row, Go, Don’t go, and Helicopter.
METHANE
An operational incident reporting acronym standing for: Major incident, Exact Location, Type of Incident, Hazards, Access and egress, Number of casualties, Emergency services.
Systems of Work for SWAH
The three operational working systems used in Safe Working at Height: Work restraint, Work positioning, and Fall arrest.
CREST
A pumping acronym standing for: Create Flow, Resistance, Entry Loss, Strainer, Temperature.
Failed Prime Causes
Issues during open water pumping including an inadequately submerged strainer, loose or faulty suction joints, open drain valve or deliveries, defective primer, air leaks in suction hose, or a faulty gauge.
Delivery Pressure Increase Causes
Factors during open water pumping that elevate delivery pressure: closing down branches, debris on delivery hose, vehicle on delivery hose, or a kink in the delivery hose.
Delivery Pressure Decrease Causes
Factors during open water pumping that lower delivery pressure: a burst length, branches being opened, or debris/vehicles moving off the delivery hose.
Compound Gauge Negative Reading Increase
Pumping indicator caused by a drop in water supply level, a partially blocked strainer, or the pump working harder due to higher delivery demand.
Compound Gauge Negative Reading Decrease
Pumping indicator caused by a rise in water supply level or the pump working less due to reduced demand.
High Vacuum Gauge Reading with No Water
A condition when pumping from open water caused by a blocked strainer or a collapsed or blocked suction hose.
RTC Door Spreader Target
The top hinge, which is the initial target when utilizing hydraulic spreaders to remove a vehicle door.
RTC Orange Wires
High-voltage vehicle wiring that must never be cut during a road traffic collision (RTC).
Flashover Indicators
Warning signs of an impending flashover: well ventilated compartment, visible flames in smoke layer, remote pyrolysis of combustible materials, lowering of neutral plane, and a turbulent gas layer overhead.
Backdraught Indicators
Warning signs of an impending backdraught: poorly ventilated compartment, prolonged burning, extremely low neutral plane, blackened windows, whistling noise around gaps, little or no visible flame, pulsating fire gases/smoke (like breathing), and blistering paint.
Compound Gauge Negative Reading
A reading indicating the vertical depth to the water level from the eye of the pump.
SSRI
Sure Specific Risk Information; documentation created about specific sites to provide detailed hazard information to responding crews.
Blue Hydrant Plate
A marker plate indicating that the fire hydrant is located behind the plate or is hidden.
Stages of Fire Growth
The four developmental stages of a fire: Incipient, Growth, Flashover, and Decay.
EAC
Emergency Action Code Book located next to the Incident Commander (IC) seat in appliances that provides guidance on immediate actions during a hazardous materials incident.
13.5 Ladder Extended Length
The actual fully extended length of a 13.5 ladder, measuring 14.1m.
JESIP Principles of Joint Working
The five core multi-agency collaboration principles: Co-locate, Communicate, Co-ordinate, Joint understanding of risk, and Shared situational awareness.
Cavitation
The formation and collapse of vapour bubbles in a pump caused by regions of low pressure.
Stage 1 BA Maximum Wearers
The maximum permissible number of breathing apparatus wearers under Stage 1 control, which is 6.
BA Guideline Tabs
Tactile spacers on a guideline where long tabs point closest to the risk and short tabs point closest to the exit.
Low Pressure Pumping Application
The pump pressure regime used strictly when operating solely with layflat delivery hose.
Safety Command: Rest
A safety command used by a manager to safely stop an action, prompting the crew to bring the activity to a stop in a safe and controlled manner.
Safety Command: Still
An emergency safety command that can be shouted by anyone to bring everyone on scene to an immediate stop.
Safety Command: Head In
A safety command used by anyone during a ladder drill to bring the head of the ladder into the building if the crew begins losing control.
Safety Command: Stand From Under
A warning command used by anyone when dropping or lowering equipment or materials from height.
Four Pump Categories
The primary classifications of fire pumps: Positive Displacement, Gas Exhaust Ejector, Centrifugal, and Peripheral Pump.
Layflat Hose Length
The standard manufactured length of a single section of layflat hose, measuring 23–25metres.
Mac Donald / Hermaphrodite
The specific type of non-gendered coupling used on hose reel lines.
Hydrant Plate Numbers
Identification markings on a yellow plate where the top number denotes the pipe diameter and the bottom denotes the distance from the plate.
Pressure Loss Allowances
Standard operational frictional and head losses: 0.3bar per length of 52 hose, 0.2bar per length of 70 hose, and 0.5bar per floor of elevation rise.
Positive Pressure Ventilation (PPV) Phases
The ventilation phases: Phase 1 (crews committed, fire extinguished, smoke clearance), Phase 2 (indirect attack, fire located/suppressed/anti-vented, search aid), Phase 3 Direct Committed (crews committed, fire controlled), Phase 3 Direct Not Committed (crews uncommitted, fire not extinguished).
Fireground Radio Channels
Channel assignments: 1 General Incident, 2 Portable Repeaters, 3 BA, 4 Command Support, 5 Fixed Site Repeaters, 6 BA sector / functional roles, 7 service defined, and 8 incident defined.
Airwave Radio Keypad Actions
Priority button functions: 9 sends a Group Urgent request to speak, 3 sends a Private urgent request to speak, 7 sends a Group request to speak, and 1 sends a Private request to speak.
SPAR
An operational structure standing for Situation, Priorities, Actions, and Risk; used to transmit informative radio messages to control.
STAR
A dynamic individual risk assessment process used when working unsupervised, standing for Stop, Think, Act, and Review.
Petzl ID
Petzl Industrial Descender; an operational friction device used within Safe Working at Height (SWAH) systems to control descent.
SWAH Hierarchy of Control
The safety priority sequence applied to working at height: Avoid, Prevent, Minimise.
Hand Sandwich
The required contact sequence when stepping across and transferring onto a roof ladder: Foot, hand, hand, foot.
Strainer Submergence Depth
The optimal working submergence depth when drafting open water, specified as 3× the diameter of the suction hose.
Hazmat Class 1
Dangerous goods category covering Explosives.
Hazmat Class 2
Dangerous goods category comprising Non-flammable gas, Oxygen, Flammable gas, and Inhalation hazard.
Hazmat Class 3
Dangerous goods category covering Flammable liquids and Combustible liquids.
Hazmat Class 4
Dangerous goods category comprising Flammable solids, Dangerous when wet materials, and Spontaneously combustible substances.
Hazmat Class 5
Dangerous goods category encompassing Flammable organic peroxides, Oxidising organic peroxides, and Oxidisers.
Hazmat Class 6
Dangerous goods category consisting of Inhalation hazards and Poisons (toxic substances).
Hazmat Class 7
Dangerous goods category covering Radioactive substances.
Hazmat Class 8
Dangerous goods category covering Corrosive substances.
Hazmat Class 9
Dangerous goods category covering Miscellaneous hazards.
Initial Hazmat Cordon Distances
The baseline safety cordon perimeters: 25m for solids, 50m for liquids, and 100m for gases.
Hazmat Routes of Entry
The four bodily exposure pathways for toxic substances: Inhalation, Ingestion, Injection, and Absorption.
Methods of Heat Transfer
Conduction (heat transferred through molecular contact in an object), Convection (upward travel of hot gases), and Radiation (heat traveling in straight lines from the source).
Six Classes of Fire
Class A (Carbonaceous), Class B (Flammable Liquids), Class C (Flammable Gases), Class D (Flammable Metals), Electrical, and Class F (Cooking oils).
Water Fire Extinguisher
A red-coded extinguisher designated exclusively for suppressing Class A carbonaceous fires.
Foam Fire Extinguisher
A cream-coded extinguisher utilized for fighting both Class A and Class B fires.
Dry Powder Extinguisher
A blue-coded unit used on Class A, B, C, and Electrical fires; specialized dry powder variants are dedicated to Class D fires only.
CO2 Fire Extinguisher
A black-coded extinguisher used on Class B and Electrical fires.
Wet Chemical Extinguisher
A yellow-coded extinguisher specifically rated for Class A and Class F (cooking oil) fires.
Landfill Site Gases
The primary gases generated by landfills: Methane (flammable and explosive), Carbon dioxide (asphyxiate), and Hydrogen sulphide (toxic, irritant, and corrosive).
CBRN(e)
Hazardous materials acronym standing for Chemical, Biological, Radiological, Nuclear, and Explosive.
PTO
An appliance mechanical subsystem abbreviation standing for Power Take Off.
Four Properties of Foam
The critical extinguishing characteristics of firefighting foam: Stable, Contamination resistant, Resealing, and Burn back resistant.
Life Jacket Safety Boundary
The proximity rule mandating that personnel wear a life jacket when working within 3metres of open water.
Ladder Pitch Distance
The safe placement distance of a ladder heel from the structure, defined as 31 of the working height.
BA Re-entry Pressure
The minimum operational cylinder pressure required for a crew to perform a breathing apparatus re-entry, set at 160bar.
DSU Alert Intervals
The Distress Signal Unit automatic timeline, activating a pre-alarm at 15seconds of inactivity and a full automatic alert at 30seconds.
Pyrolysis
The chemical decomposition of flammable materials directly induced by the application of heat.
BA Initial Risk Area Entry Pressure
The strict minimum cylinder pressure required for a breathing apparatus wearer to enter a risk area, which is 240bar.
RICE
An operational decision-making model standing for: Rescue, Intervention, Containment, Evacuation.
Wind Driven Fire Indicators
Observable cues including hot gases exhausted at low levels, roaring noises, rapid air outflow at low levels through doorways, evident external wind, and noticeable air movement through the building.
SWAH Line Knot Position
The designated location of the stopper or safety knot on a height safety line, placed at the bottom end.
Hose Safe Working Pressures
The rated operational limits for delivery equipment: 30bar for hose reel and 10bar for layflat.
Six Stages of RTC
Phase 1: Scene assessment and safety; Phase 2: Stabilisation and initial access; Phase 3: Glass management; Phase 4: Space creation; Phase 5: Full access; Phase 6: Immobilisation and extrication.
RTC Battery Isolation
The safety disconnection of the negative terminal, identified by its black colour.
High Pressure vs Low Pressure Output
The hydraulic comparative ratio in a dual-stage pump, where the high-pressure stage produces 4× more pressure than the low-pressure stage.
Cleveland Lay Length
The total single assembled hose length of a Cleveland lay setup, measuring 30m.
Initial Delivery Pressures
Baseline startup pressures: 20–25bar for hose reel jets (30bar for internal firefighting) and 3bar for main lines.
Working Delivery Pressures
Standard operating line pressures: 30bar for hose reel jets and 8bar for main lines.
Gas Tight Suit Maximum Duration
The absolute maximum allowable working period for personnel deployed inside a gas tight suit, which is 20minutes.
Telemetry Board Time Elapsed
A monitoring readout showing how long the BA set has been turned on or how long the tally has been inserted without an active telemetry link.
BA Cylinder Pressure Checkpoints
Key pressure thresholds: 270bar minimum to pass the BA test, 240bar to enter the risk area, and 160bar for re-entry.
BA Cable Cutters Rating
The maximum electrical isolation threshold of standard BA set cable cutters, rated up to 1000V.
Respiratory Gas Composition
Inhalation consists of 79% Nitrogen and rare gases, 21% Oxygen, and trace CO2; Exhalation consists of 79% Nitrogen, 17% Oxygen, and 4% CO2.
Anchor Point Requirement
The fundamental safety requirement for any rigging attachment in SWAH: it must be unquestionably reliable.
Acceptable SWAH Anchor Points
Approved structural fixtures: trees of 15cm diameter or more, parts of a building, concrete pillars, steel structures, ground anchors, reveal ties (DWFRS ladders), DWFRS vehicles, and roadside furniture.
Down Up Rescue Requirements
Mandatory criteria: a full Dynamic Risk Assessment (DRA) carried out by the Officer in Charge (OIC), immediate risk to life, mobilisation of a Level 3 team, and additional friction introduced into the system.
Blue Railway Sign
Trackside marker designating an upcoming railway tunnel that lacks a refuge point.
Relay Pumping Hose Spacing
The maximum number of hose lengths permissible between operating pumps when drafting from open water, which is 8 lengths.
Duty Point of a Pump
The precise operational output pressure and discharge rate at which a pump operates at its peak efficiency.
Appliance Primer
A positive displacement or reciprocating primer mechanism fitted to operational vehicle pumps.
Shallow Basement Depth
A subterranean structure with a maximum depth extending no deeper than 10m.
Hazmat Large Volume Threshold
The containment volume threshold defining a large hazmat incident, classified as being over 208litres.
Gas Tight Suit Decon Return Pressure
The safety threshold requiring an operator to return to the decontamination point when cylinder pressure reaches 160bar.