AHS3236L: Lab 10 - Glowing, Gowning, & Neo Software

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/6

encourage image

There's no tags or description

Looks like no tags are added yet.

7 Terms

1
New cards

Closed Gloving:

  • Closed gloving

    • UNFOLD the inner glove wrap like a book - opening it from the EDGES

      • Can ONLY TOUCH the OUTSIDE of the packaging

      • NEVER TOUCH the INSIDE

      • Gloves are positioned w/ the PALMS UP

    • Hands are WITHIN the CUFFS of the gown - fingers/hands DON’T GET OUT of the gown

    • Steps:

      • With the LEFT hand, pick up the RIGHT glove by the FOLDED CUFF

      • Place the glove on the PALM w/ the fingers facing TOWARDS YOU

      • Through the GOWN CUFF, GRASP the BACK of the glove cuff w/ the RIGHT hand

      • With the LEFT hand, pull & lift the the GLOVE cuff OVER the GOWN CUFF & RIGHT hand (curl the fingers inside the glove)

      • With the LEFT hand, grasp BOTH the TOP of the RIGHT GLOVE CUFF & GOWN CUFF & PULL while pushing the hand INTO the glove

      • Pull the GOWN SLEEVE w/ LEFT hand to adjust the glove

      • Glove the LEFT hand using the SAME technique

      • AFTER putting BOTH gloves you can FIX the GLOVES


2
New cards

Open Gloving:

  • Open Gloving

    • USED when ONLY the HANDS need to be STERILE & NO GOWN is NEEDED such as:

      • Minor surgical procedures

      • Bone marrow biopsies

      • Urinary catheterizations

      • Paracentesis

      • Wound lacerations

    • Steps:

      • With the LEFT hand, pick up the RIGHT glove by grasping the INSIDE SURFACE of the GLOVE

      • Guide the fingers into the glove - DO NOT adjust the cuff

      • Place your RIGHT gloved fingers under the folded cuff of the LEFT glove to put it on

        • The SECOND glove is put on BEFORE the cuff of the FIRST glove is UNFOLDED up the wrist

      • Slide the fingers of the LEFT hand into the glove

      • Pull the cuff of the LEFT glove up the ARM & away from the WRIST

      • Once the LEFT glove is ALL the way on, the cuff of the RIGHT glove can be UNFOLDED & EXTENDED up the arm

        • ONLY the FINGERS (NOT THUMB) of the LEFT hand are used to unfold the cuff - to PREVENT the thumb from touching the exposed skin on the arm


3
New cards

Removing gloves/Changing gloves:

  • Removing gloves:

    • Grasp/pinch the GLOVE & GOWN CUFF together,WITHOUT touching the gown sleeve & PULL to remove glove

  • Changing gloves when:

    • Tear

    • Bloody

    • Greasy

    • Overall when it is CONTAMINATED


4
New cards

Gowning:

  • Steps:

    • Grasp the whole gown & lift the folded gown out of the package

    • STEP AWAY from the table to PREVENT the gown from touching any NONSTERILE items as it unfolds

    • HOLD the gown by the NECKLINE & allow it to unfold

    • Slide BOTH arms into the sleeves of the gown at the SAME TIME

      • The scrubbed person’s hands remain INSIDE the CUFFS of the gown

    • The circulating assistant will continue to pull the gown onto the scrubbed-in-person, bring the gown over the shoulders, fasten the neck of the gown, & tying the waistline

      • All of this is performed while STANDING BEHIND the person gowning & touching ONLY the HEM of the collar & BACK of the gown


5
New cards

Surgical hand scrub:

  • Wash hands & forearms to the elbows w/ antimicrobial scrub & running water BEFORE beginning the surgical scrub

  • Use a nail pick to clean UNDER the fingernails

  • KEEP hands ABOVE the elbows & allow water to RUN OFF at the ELBOWS

  • Steps:

    • Apply antimicrobial agent to WET hands & forearms

    • BEGIN by brushing the the FINGERTIPS of the first hand 10 times

    • Move to the LATERAL side of the INDEX FINGER & scrub from the TIP to the BASE of the finger 10 times

    • Repeat the 10-time scrubbing process on the other 3 sides of the INDEX FINGER

      • Make sure that the brush & antimicrobial scrub also contact the WEBBING between fingers

    • Move to the other THREE fingers & REPEAT the process on ALL SIDES of each finger

    • When scrubbing the LATERAL side of the LAST finger (pinky), make sure to scrub the lateral side of the hand in the SAME MOTION

    • Move the brush to the PALM of the hand & scrub 10 times

    • Move to the THUMB side of the hand & scrub the OUTSIDE of the THUMB & the SIDE of the hand in ONE MOTION

    • Move to the BACK of the hand & scrub from the BASE of the FINGERS to the WRIST using 10 STROKES

    • Scrub the ARM from the WRIST to the ELBOW using 10 STOKES on EACH of the FOUR sides of the arm

    • Leaving the antimicrobial scrub on the FIRST arm, proceed to the SECOND arm & follow the same process

    • When the scrub on BOTH arms is complete, RINSE the FIRST ARM, BEGINNING at the FINGERTIPS

      • KEEP the hands ABOVE the ELBOWS & ALLOW water to RUN OFF the ELBOW

      • DO NOT let hands or arms TOUCH ANYTHING (ex: sink, scrub top)


6
New cards

Drying the hands:

  • Each CORNER of the the towel is used for each HAND & ARM

  • DRY from DISTAL to PROXIMAL

  • Steps:

    • Open the towel FULL LENGTH, using ONE END of the towel to gently rub the FINGERS, HAND, & ARM of the FIRST HAND & ARM

    • DO NOT rub back & forth - INSTEAD rub/pat BEGINNING at the WRIST & moving to the ELBOW

    • When ready to dry the SECOND hand & arm, bring the FIRST, DRY hand to the OPPOSITE end of the towel & repeat


7
New cards

Neo Software:

  • USED to pull patients profile/medical records & to order diagnostic

  • Connected to the CATALYST machine (used to run chemistry) & PROCYTE machine (used to run CBC)

  • Catalyst machine

    • Insert LYTE 4 - FIRST

    • CHEM - SECOND

    • Put the slides in BIOHAZARD

    • Add BLOOD SAMPLE - using GREEN cap whole blood separator(containing HEPARIN)

      • Need 0.7 cc of BLOOD

      • For a regular green top tube CENTRIFUGE the tube & PIPETTE the PLASMA into a Catalyst sample cup

    • Make sure PIPETTES are FULL

  • Procyte machine

    • INSERT LAVENDER top tube w/ blood

      • INVERT lavender top tube 10 times BEFORE putting it inside the machine