Ch.1 Imaging Principles and Radiation Protection

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/228

encourage image

There's no tags or description

Looks like no tags are added yet.

229 Terms

1
New cards

What are the three major factors affecting radiographic quality?

Receptor exposure, spatial resolution, and distortion.

2
New cards

What is receptor exposure?

The degree to which an image receptor is exposed to ionizing radiation.

3
New cards

What is the primary controlling factor of receptor exposure?

mAs.

4
New cards

What does mA control?

The quantity of x-ray photons produced per unit of time.

5
New cards

What does exposure time control?

The duration of x-ray production.

6
New cards

What does mAs stand for?

Milliampere-seconds.

7
New cards

How is mAs calculated?

mA multiplied by exposure time in seconds.

8
New cards

What happens to receptor exposure when mAs doubles?

Receptor exposure doubles.

9
New cards

What is the secondary controlling factor of receptor exposure?

kVp.

10
New cards

What does kVp primarily control?

The energy and penetrating power of the x-ray beam.

11
New cards

What does the 15% rule state?

Increasing kVp by 15% approximately doubles receptor exposure.

12
New cards

How should mAs be adjusted when kVp increases by 15% to maintain receptor exposure?

Decrease mAs by half.

13
New cards

How should mAs be adjusted when kVp decreases by 15% to maintain receptor exposure?

Double the mAs.

14
New cards

What does SID stand for?

Source-to-image receptor distance.

15
New cards

What happens to receptor exposure when SID increases without adjusting technique?

Receptor exposure decreases.

16
New cards

What law describes the relationship between distance and radiation intensity?

Inverse square law.

17
New cards

What happens to radiation intensity when distance is doubled?

It decreases to one-fourth.

18
New cards

What happens to radiation intensity when distance is cut in half?

It increases four times.

19
New cards

What is the primary purpose of a grid?

To absorb scatter radiation before it reaches the image receptor.

20
New cards

What material is commonly used in the absorbing strips of a grid?

Lead.

21
New cards

How does a grid improve image quality?

It reduces scatter radiation and improves contrast.

22
New cards

Does using a physical grid generally require an increase or decrease in exposure factors?

An increase.

23
New cards

What is grid cutoff?

A reduction in receptor exposure caused by unwanted absorption of primary radiation by the grid.

24
New cards

What is a virtual grid?

Scatter correction software that produces an image similar to one obtained using a physical grid.

25
New cards

What is the purpose of collimation?

To restrict the x-ray beam to the area of interest.

26
New cards

How does decreasing collimation field size affect scatter radiation?

It decreases scatter radiation.

27
New cards

How does decreasing collimation field size affect image contrast?

It improves image contrast.

28
New cards

What is an exposure indicator?

A numerical value representative of the radiation exposure received by the image receptor.

29
New cards

What does EI stand for?

Exposure index or exposure indicator.

30
New cards

What does the S-number represent?

A sensitivity number used as an exposure indicator.

31
New cards

What does REX stand for?

Reached exposure value.

32
New cards

What does DEI stand for?

Detector exposure index.

33
New cards

What are the two possible relationships between exposure indicators and receptor exposure?

Direct and inverse relationships.

34
New cards

In a directly proportional system, what happens to EI when receptor exposure increases?

EI increases.

35
New cards

In a directly proportional system, what happens to EI when receptor exposure decreases?

EI decreases.

36
New cards

In an inversely proportional system, what happens to EI when receptor exposure increases?

EI decreases.

37
New cards

In an inversely proportional system, what happens to EI when receptor exposure decreases?

EI increases.

38
New cards

In an inverse EI system with an acceptable range of 400–800, which number represents greater receptor exposure?

400.

39
New cards

Why should a technologist check the exposure indicator?

To help ensure adequate receptor exposure with the least possible patient dose.

40
New cards

What factors affect the exposure indicator?

mAs, kVp, detector area irradiated, and objects exposed.

41
New cards

Can an overexposed digital image still appear acceptable on a monitor?

Yes.

42
New cards

What does insufficient receptor exposure produce?

A noisy image.

43
New cards

What does excessive receptor exposure cause?

Unnecessary radiation exposure to the patient.

44
New cards

Is the exposure indicator a direct measurement of patient dose?

No. It represents exposure received by the image receptor.

45
New cards

What is spatial resolution?

The recorded sharpness of structures on an image.

46
New cards

What are other terms for spatial resolution?

Detail, recorded detail, image sharpness, and definition.

47
New cards

How is spatial resolution measured?

Line pairs per millimeter (lp/mm).

48
New cards

What is a lack of spatial resolution called?

Blur or unsharpness.

49
New cards

What is the greatest deterrent to image sharpness?

Motion.

50
New cards

What are the two types of motion?

Voluntary and involuntary motion.

51
New cards

What is voluntary motion?

Motion that the patient can control.

52
New cards

What is an example of voluntary motion?

Breathing or body movement.

53
New cards

What is involuntary motion?

Motion that the patient cannot consciously control.

54
New cards

What is an example of involuntary motion?

Peristalsis.

55
New cards

How can voluntary motion be minimized?

Patient instructions, cooperation, immobilization, and short exposure times.

56
New cards

How can involuntary motion be minimized?

Short exposure times.

57
New cards

Does motion increase or decrease spatial resolution?

Decrease.

58
New cards

Which focal spot size produces better recorded detail?

Small focal spot.

59
New cards

What is geometric unsharpness?

Blurring of object edges caused by imaging geometry and focal spot size.

60
New cards

What is penumbra?

The unsharp edges of a projected image.

61
New cards

Which focal spot produces less penumbra?

Small focal spot.

62
New cards

How does increasing SID affect spatial resolution?

It improves spatial resolution.

63
New cards

What does OID stand for?

Object-to-image receptor distance.

64
New cards

How does decreasing OID affect spatial resolution?

It improves spatial resolution.

65
New cards

What factors improve spatial resolution?

Small focal spot, short exposure time, faster IR system, longer SID, and shorter OID.

66
New cards

What is distortion?

Misrepresentation of the size or shape of an object on an image.

67
New cards

What are the two types of distortion?

Size distortion and shape distortion.

68
New cards

What is another name for size distortion?

Magnification.

69
New cards

What is magnification?

An increase in the apparent size of an object on an image.

70
New cards

What are the four controlling factors of distortion?

SID, OID, object-IR alignment, and CR alignment.

71
New cards

How does increasing SID affect magnification?

It decreases magnification.

72
New cards

How does decreasing SID affect magnification?

It increases magnification.

73
New cards

How does increasing OID affect magnification?

It increases magnification.

74
New cards

How does decreasing OID affect magnification?

It decreases magnification.

75
New cards

What SID is commonly used for routine skeletal radiography?

40 inches.

76
New cards

What SID is commonly used for chest radiography?

72 inches.

77
New cards

Why is a longer SID used for chest radiography?

To minimize magnification of the heart and other structures.

78
New cards

How should the object be aligned with the IR to minimize distortion?

Parallel to the IR.

79
New cards

What happens when the object is not parallel to the IR?

Shape and size distortion may occur.

80
New cards

What happens to distortion as the angle of inclination between the object and IR increases?

Distortion increases.

81
New cards

What is foreshortening?

Shape distortion in which anatomy appears shorter than its actual length.

82
New cards

What is elongation?

Shape distortion in which anatomy appears longer than its actual length.

83
New cards

What does CR stand for?

Central ray.

84
New cards

Where does the least possible distortion occur within the x-ray beam?

At the central ray.

85
New cards

How is the CR normally aligned to the IR?

Perpendicular, or at 90 degrees.

86
New cards

How does distortion change as beam divergence increases away from the CR?

Distortion increases.

87
New cards

How should digits be aligned with the IR to demonstrate open interphalangeal joints?

Parallel to the IR.

88
New cards

What happens to interphalangeal joint spaces when the digits are not parallel to the IR?

The joint spaces may appear closed.

89
New cards

Why is correct CR centering important?

To minimize distortion and demonstrate anatomy accurately.

90
New cards

What are the three major digital imaging characteristics?

Spatial resolution, contrast resolution, and image signal.

91
New cards

What is a pixel?

A picture element in a digital image.

92
New cards

What is a matrix?

An arrangement of pixels in rows and columns.

93
New cards

How does decreasing pixel size affect spatial resolution?

It improves spatial resolution.

94
New cards

How does increasing matrix size affect pixel size when the field of view remains constant?

Pixel size decreases.

95
New cards

What is pixel pitch?

The distance from the center of one pixel to the center of an adjacent pixel.

96
New cards

How does decreasing pixel pitch affect spatial resolution?

It improves spatial resolution.

97
New cards

What is MTF?

Modulation transfer function, a measure used to evaluate imaging system resolution.

98
New cards

What does contrast describe?

The differences in brightness between light and dark areas of an image.

99
New cards

What is contrast resolution?

The ability of an imaging system to distinguish small differences in intensity.

100
New cards

What is high contrast?

Fewer shades of gray with greater differences between light and dark areas.