1/8
"Question n, part c" type of questions. The actual "working & calculations" are not part of this.
Which would you choose for a severe quench and which for a moderate one?
Given their coe of thermal expansion, thermal conductivity, max quench (severe), and max moderate quench.
Typical answer (the choice & some numerical statements)
Both (severe & moderate quench) are simplified thermal shock measures:
actual survival also depends on:
part’s geometry
heat-transfer conditions
part’s constraints.
A lunar rover is to be kept warm during the lunar night. Assuming the 50 W heater operates continuously throughout, how much electrical energy does it consume?
Typical answer (calculations answer in Ws, Wh, or kWh)
The actual heater power depends on:
thermal losses
insulation
the surrounding conditions.
A lunar rover (Al box) is to be kept warm during the lunar night. Assuming the 50 W heater operates continuously throughout, how much electrical energy does it consume?
A polymer box of the same mass (cp = 1900 J/kg·K) would need more or less heat?
Typical answer (calculations answer in Ws, Wh, or kWh)
But a polymer stores more heat than Al, so might need less due to the insulation of the polymer.
And:
A good design should use insulation to cut thermal losses, and so heater power.
A beam undergoes ΔT=−203K .
a) If clamped rigidly at both ends, what thermal stress is produced? State whether it is tensile or compressive.
b) And if it can reach ΔT=−203K?
Typical answer (Stress=Ɛ⋅E, where Ɛ=α⋅ΔT )
Is tensile as a clamped beam can’t shorten
(It compresses (tries to shorten) towards the clamp on both ends, therefore there is a tensile stress in the middle, where the failure occurs)
A beam undergoes ΔT=−203K .
Can reach ΔT if E=200GPa α=16.5⋅10−6K−1 σyield=250MPa
Typical answer (No, ΔTmax=−75.758K)
To achieve ΔT=−203K, don’t clamp it rigidly.
Because non-rigid allows for ΔL (as the clap lets it shrink/expand), which allows it to reach it’s max Ɛ and so it’s max ΔT
POV:
A regeneratively cooled rocket chamber wall (2.5 mm thick) with hot air heat flux of 10 MW/m². For a highly constrained copper wall (λ = 320 W/m·K, E = 120 GPa, α = 17 × 10−6 /K, ν = 0.34), estimate the scale of the thermal stress using σ = EαΔT/(1 − ν) with the through-thickness ΔT.
Typical answer (Use equation, ans = 241 MPa)
This is an illustrative scale (model) for an assumed highly constrained wall, not the actual stress distribution in the chamber wall.
Actual depends on:
temperature field
boundary conditions
geometry
constraints
How does α vary with Temp
Directly proportional.
Real tiles have scratches and flaws, so a design with little margin is unsafe. (don’t lower FoS)
The procedure should:
prevent the quench (wait until the engine has cooled before washing,
use warm water (lower ΔT )
or the design should use a material with a higher E⋅ασfracture . Increase any of those.
A plate must spread heat from a hot electronics chip across a square 0.2 m panel (2mm thick) on a satellite, while keeping mass low.
Al - (λ = 247 W/m·K, ρ = 2700 kg/m³, cp = 900 J/kg·K)
Cu - (λ = 390, ρ = 8960, cp = 385)
C composite - (λ = 1, ρ = 1600, cp = 900)
For simplicity, model the carbon-fibre laminate as a homogeneous material with an effective isotropic thermal conductivity of 1 W/(m·K); directional differences in conductivity are neglected in this introductory calculation.
Calculate the diffusivity
Estimate the spreading time over L = 0.2 m. (t ≈ L²/a)
Compare the mass per square metre & choose
Typical answer (Use eqn to solve, compare with numbers, pick one, use numbers to explain choice)
Al - a = 102, t = 393.5s, m = 0.216, m/A = 5.4
Cu - a = 113, t = 353.8s, m = 0.7168, m/A = 7.92
C composite - a = 0.694, t = 57600s, m = 0.128, m/A = 3.2
Choose Al, is ~x3.5 lighter than Cu, even though ~x1.11 slower at heat transfer
The figure is the result of the assumed effective conductivity, not a universal value for real carbon-fibre laminates, which can conduct heat differently in different directions.