For roof structures and attics, the inspector is not required to enter attics or unfinished spaces where openings are less than 22 by 30 inches or headroom is less than ____ inches

30

2
New cards

Inspector must report the ____ of foundation

type

3
New cards

For cooling systems, the inspector shall report as deficient a primary drainpipe that discharges in a ____

sewer vent

4
New cards

For electrical systems, the inspector shall report as deficient ___ or ____ receptacle, switch or junction box covers

missing, damaged

5
New cards

For Porches, Balconies, Decks, and Carports, the inspector is not required to enter any area where headroom is less than ___ inches or the acess opening is less than ____ inches wide and 18 inches high

18 , 24

6
New cards

For foundations, the inspector is not required to provide an exhaustive list of indicators of ___ adverse performance

possible

7
New cards

For electrical systems, the inspector is not required to remove the covers of junction, fixture, receptacle, or switch boxes unless __

specifically required by these standards

8
New cards

For exterior and interior stairways spacing between intermediate balusters, spindles, or rails for steps, stairways, guards, and railings that permit passage of an object greater than _____ inches in diameter, except that on the open side of the staircase treads, spheres less than ____ inches in diameter may pass through the guard rail balusters or spindles.

4 , 4-3/8

9
New cards

The roof structures and attics, the inspector is not required to provide an ____ list of locations of deficiencies and water penetrations

exhaustive

10
New cards

For roof structures and attics, the inspector is required to do all of the following except

Provide an exhaustive list of locations of deficiencies and water penetrations

11
New cards

For Porches, Balconies, Decks, and Carports, the inspector shall inspect

abutting porches, decks, and balconies that are used for ingress and egress

12
New cards

Smoke alarms should be present in

every bedroom

13
New cards

For electrical systems, the inspector is not required to

Test arc fault circuit interrupter devices when the property is occupied

14
New cards

For gas heating systems, the inspector shall report deficiencies in access to a gas shutoff valves that prohibits full ___

Operation

15
New cards

For grading and drainage, the inspector is not required to determine area hydrology or the presence of ___

Underground water

16
New cards

For HVAC systems, the inspector shall report as deficient heating equipment with the absence of an opening that would allow access to equipment for inspection, service, repair or replacement without removing ____ construction or building finish.

Permanent

17
New cards

For gas heating systems, the inspector shall report deficiencies in all of the following except:

sediment in gas line

18
New cards

For Porches, Balconies, Decks, and Carports, the inspector is not required to enter any area where headroom is less than 18-inches or the access opening is less than 24 inches wide and _____ inches high.

18

19
New cards

For roof covering materials, the inspector is not required to inspect the roof from the roof level if, in the inspectors reasonable judgment ___

significant damage to the roof covering materials may result from walking on roof

20
New cards

For electrical systems, the inspector shall report as deficient the absence of ground-fault circuit interrupter protection in all ____

basement receptacles

21
New cards

For exterior walls, doors and windows, the inspector shall report as deficient all except:

deficiencies in awnings, blinds, shutters

22
New cards

When inspecting the attic, the inspector is required to____

report missing insulation

23
New cards

For HVAC systems, the inspector is not required to do all of the following except:

identify heating energy source

24
New cards

For HVAC systems, the inspector shall report as deficient heating equipment with burners, burner ignition devices or heating elements, switches, and thermostats that are not a minimum of _____ inches above the lowest garage floor elevation, unless the unit is listed for garage floor installation.

18

25
New cards

For HVAC systems, the inspector shall report all of the following except

the location of heating systems

26
New cards

For electrical systems, the absence of ___ should be reported as a deficiency

a main disconnecting means

27
New cards

For electrical systems, the inspector shall report as deficient missing or damaged ___ or covers plates.

dead fronts

28
New cards

For roof covering materials, the inspector is not required to inspect the roof from the roof level if, in the inspectors reasonable judgment

the inspector cannot safely reach or stay on the roof

29
New cards

For fireplace and chimneys, the inspector shall report as deficient all of the following except

the presence of fire blocking at the attic penetration of the chimney flue where accessible

30
New cards

For electrical systems, the inspector shall report as deficient electrical cabinets and panel boards that are not accessible or do not have a minimum of ___ inches of clearance in front of them.

36

31
New cards

For roof covering materials, the inspector ___ required to provide an exhaustive list of location of deficiencies and water penetrations

is not

32
New cards

The lack of ground fault circuit interrupter protection in all ____ receptacles should be reported as deficient

bathroom, garage, and crawlspace

33
New cards

For electric heating units, the inspector shall report deficiencies in all of the following except

location of heating unit

34
New cards

For Porches, Balconies, Decks, and Carports, on decks ______ inches or higher above the adjacent grade, spacings between intermediate balusters, spindles, or rails that permit passage of an object greater than four (4) inches in diameter.

30

35
New cards

For electrical systems, the inspector shall report as deficient the absence of ___ on 250 volt overcurrent devices or multiwire branch circuit

trip ties

36
New cards

For fireplaces and chimneys, the inspector is not required to do any of the following except

report built up creosote in the flue

37
New cards

For electrical systems an example of electrical cabinets and panel boards not appropriate for their location would be ____

a clothes closet

38
New cards

For evaporative cooling systems, the inspector must report the type of system and ____

the type of water supply line

39
New cards

For electrical systems, the inspector shall report as deficient the absence of anti-oxidants on ___ conductor terminations

aluminum

40
New cards

For roof covering materials, the inspector is not required to determine ____

the number of layers of roof covering materials

41
New cards

For walls, ceiling, floors, and doors, the inspector shall report as deficient all except

the absence of performing emergency escape and rescue opening in most sleeping rooms

42
New cards

For cooling systems, the inspector shall report as deficient condensing units lacking adequate clearances or air circulation or that has deficiencies in the fins, location, ____, or elevation above grade surfaces.

levelness

43
New cards

For roof structures and attics, the inspector shall report the ____ from which the attic space was inspected

vantage point

44
New cards

An inspector should report ____ at the evaporative cooler

the type of water supply line

45
New cards

A deficiency in the evaporative cooler would include

the absence of backflow prevention

46
New cards

For fireplaces and chimneys, the inspector shall report deficiencies in all of these areas except the ___

circulating vents

47
New cards
48
New cards
49