For roof structures and attics, the inspector is not required to enter attics or unfinished spaces where openings are less than 22 by 30 inches or headroom is less than ____ inches
30
Inspector must report the ____ of foundation
type
For cooling systems, the inspector shall report as deficient a primary drainpipe that discharges in a ____
sewer vent
For electrical systems, the inspector shall report as deficient ___ or ____ receptacle, switch or junction box covers
missing, damaged
For Porches, Balconies, Decks, and Carports, the inspector is not required to enter any area where headroom is less than ___ inches or the acess opening is less than ____ inches wide and 18 inches high
18 , 24
For foundations, the inspector is not required to provide an exhaustive list of indicators of ___ adverse performance
possible
For electrical systems, the inspector is not required to remove the covers of junction, fixture, receptacle, or switch boxes unless __
specifically required by these standards
For exterior and interior stairways spacing between intermediate balusters, spindles, or rails for steps, stairways, guards, and railings that permit passage of an object greater than _____ inches in diameter, except that on the open side of the staircase treads, spheres less than ____ inches in diameter may pass through the guard rail balusters or spindles.
4 , 4-3/8
The roof structures and attics, the inspector is not required to provide an ____ list of locations of deficiencies and water penetrations
exhaustive
For roof structures and attics, the inspector is required to do all of the following except
Provide an exhaustive list of locations of deficiencies and water penetrations
For Porches, Balconies, Decks, and Carports, the inspector shall inspect
abutting porches, decks, and balconies that are used for ingress and egress
Smoke alarms should be present in
every bedroom
For electrical systems, the inspector is not required to
Test arc fault circuit interrupter devices when the property is occupied
For gas heating systems, the inspector shall report deficiencies in access to a gas shutoff valves that prohibits full ___
Operation
For grading and drainage, the inspector is not required to determine area hydrology or the presence of ___
Underground water
For HVAC systems, the inspector shall report as deficient heating equipment with the absence of an opening that would allow access to equipment for inspection, service, repair or replacement without removing ____ construction or building finish.
Permanent
For gas heating systems, the inspector shall report deficiencies in all of the following except:
sediment in gas line
For Porches, Balconies, Decks, and Carports, the inspector is not required to enter any area where headroom is less than 18-inches or the access opening is less than 24 inches wide and _____ inches high.
18
For roof covering materials, the inspector is not required to inspect the roof from the roof level if, in the inspectors reasonable judgment ___
significant damage to the roof covering materials may result from walking on roof
For electrical systems, the inspector shall report as deficient the absence of ground-fault circuit interrupter protection in all ____
basement receptacles
For exterior walls, doors and windows, the inspector shall report as deficient all except:
deficiencies in awnings, blinds, shutters
When inspecting the attic, the inspector is required to____
report missing insulation
For HVAC systems, the inspector is not required to do all of the following except:
identify heating energy source
For HVAC systems, the inspector shall report as deficient heating equipment with burners, burner ignition devices or heating elements, switches, and thermostats that are not a minimum of _____ inches above the lowest garage floor elevation, unless the unit is listed for garage floor installation.
18
For HVAC systems, the inspector shall report all of the following except
the location of heating systems
For electrical systems, the absence of ___ should be reported as a deficiency
a main disconnecting means
For electrical systems, the inspector shall report as deficient missing or damaged ___ or covers plates.
dead fronts
For roof covering materials, the inspector is not required to inspect the roof from the roof level if, in the inspectors reasonable judgment
the inspector cannot safely reach or stay on the roof
For fireplace and chimneys, the inspector shall report as deficient all of the following except
the presence of fire blocking at the attic penetration of the chimney flue where accessible
For electrical systems, the inspector shall report as deficient electrical cabinets and panel boards that are not accessible or do not have a minimum of ___ inches of clearance in front of them.
36
For roof covering materials, the inspector ___ required to provide an exhaustive list of location of deficiencies and water penetrations
is not
The lack of ground fault circuit interrupter protection in all ____ receptacles should be reported as deficient
bathroom, garage, and crawlspace
For electric heating units, the inspector shall report deficiencies in all of the following except
location of heating unit
For Porches, Balconies, Decks, and Carports, on decks ______ inches or higher above the adjacent grade, spacings between intermediate balusters, spindles, or rails that permit passage of an object greater than four (4) inches in diameter.
30
For electrical systems, the inspector shall report as deficient the absence of ___ on 250 volt overcurrent devices or multiwire branch circuit
trip ties
For fireplaces and chimneys, the inspector is not required to do any of the following except
report built up creosote in the flue
For electrical systems an example of electrical cabinets and panel boards not appropriate for their location would be ____
a clothes closet
For evaporative cooling systems, the inspector must report the type of system and ____
the type of water supply line
For electrical systems, the inspector shall report as deficient the absence of anti-oxidants on ___ conductor terminations
aluminum
For roof covering materials, the inspector is not required to determine ____
the number of layers of roof covering materials
For walls, ceiling, floors, and doors, the inspector shall report as deficient all except
the absence of performing emergency escape and rescue opening in most sleeping rooms
For cooling systems, the inspector shall report as deficient condensing units lacking adequate clearances or air circulation or that has deficiencies in the fins, location, ____, or elevation above grade surfaces.
levelness
For roof structures and attics, the inspector shall report the ____ from which the attic space was inspected
vantage point
An inspector should report ____ at the evaporative cooler
the type of water supply line
A deficiency in the evaporative cooler would include
the absence of backflow prevention
For fireplaces and chimneys, the inspector shall report deficiencies in all of these areas except the ___
circulating vents