Dental X-ray Image Characteristics

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/20

encourage image

There's no tags or description

Looks like no tags are added yet.

Last updated 9:33 AM on 10/19/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

21 Terms

1
New cards

radiolucent

Radiographic Density & Contrast

  • Dark/black areas on a radiograph (e.g., air spaces, caries).


2
New cards

radiopaque

Radiographic Density & Contrast

  • Light/white areas on a radiograph (e.g., enamel, dentin, bone).


3
New cards

Milliamperage (mA), Kilovoltage (kVp), Exposure time

exposure factors of density

4
New cards

Thickness, density, film fog

subject factors of density

5
New cards

higher density (darker image)

Effect of kVp on Density

  • higher kVp =


6
New cards

lower density (lighter image)

Effect of kVp on Density

  • lower kVp =


7
New cards

film contrast

Contrast (Difference in degrees of blackness)

  • Film quality and processing


8
New cards

subject. contrast

Contrast (Difference in degrees of blackness)

  • Object thickness, density, and composition


9
New cards

short-scale contrast

Effect of kVp on Contrast

  • Only black & white (low kVp)


10
New cards

long-scale contrast

Effect of kVp on Contrast

  • Many shades of gray (high kVp)


11
New cards

penumbra

Sharpness (Detail, resolution, or definition)

  • Unclear, blurred edges of an image.


12
New cards

focal spot size, film composition, movement

factors affecting sharpness

13
New cards

higher sharpness

factors affecting sharpness

  • lower focal spot


14
New cards

higher sharpness

factors affecting sharpness

  • lower crystal size


15
New cards

higher sharpness

factors affecting sharpness

  • lower movement


16
New cards

target film distance

Magnification (Enlargement of image)

  • xray source to film


17
New cards

object film distance

Magnification (Enlargement of image)

  • tooth to film


18
New cards

less magnification

longer PID =

19
New cards

less magnification

closer placement =

20
New cards

parallel

Distortion (Change in shape or size)

  • Object-Film Alignment: Must be —; misalignment causes distortion.


21
New cards

perpendicular

Distortion (Change in shape or size)

  • X-ray Beam Angulation: Must be — to the tooth and film to maintain accuracy.