Automatic sprinkler system
A system of water pipes, discharge nozzles, and control valves designed to activate during a fire to automatically discharge enough water to control or extinguish a fire.
Causes of sprinkler system failure to control fire
Closed valves, frozen water supplies, inadequate water supply, obstructed sprinkler discharge, and damaged sprinkler heads.
Wet pipe system
An automatic sprinkler system in which pipes are constantly filled with water under pressure; installed in heated buildings where freezing is not an issue.
Dry pipe system
A fire protection sprinkler system that has air in the piping instead of water under pressure; installed in areas subject to freezing.
Standpipe system
A fixed piping system with equipment to transport water to designated building areas where hoses can be deployed for firefighting; runs the full height of the stairwell and is supplied by the fire pump and augmented by the Siamese connection.
Standpipe outlet size and hose line requirements
Standpipes have 2½-inch threaded port outlets for fire hoses; some high-rise buildings also require 1½-inch hose lines; buildings over 275 feet in height must have a two-zone system.
Fire pump
A pump installed when a building's existing water supply is insufficient to meet fire protection system demands; provides or enhances water supply pressure and must be tested annually with the Chicago Fire Department witnessing the test.The fire pump is crucial in enhancing water supply pressure for fire protection systems in buildings where the available water supply is inadequate.
Smoke-proof tower
a protected area within a building designed to facilitate smoke evacuation and provide a safe passage for occupants during a fire. It is typically used in high-rise buildings to maintain clear evacuation routes by preventing smoke infiltration. An enclosed stairwell designed to limit penetration of smoke, heat, and toxic gases for safer occupant evacuation; required in every high-rise building exceeding 264 feet in height and constructed with a three-hour fire resistive rating (reducible to two hours if more than one is provided).
Elevator emergency recall
A system programmed into elevators to send them non-stop to the main floor so the fire department can take control during a fire or emergency; this control mode is called fireman service mode.
Fireman's recall box
A box containing the keys firefighters use to recall elevators, installed in a conspicuous location on the main floor of the elevator lobby; its size, construction, and lock type must be approved by the Chicago Fire Department.
Fire Tetrahedron
A model describing fire as requiring four components: fuel, heat, oxygen, and a molecular chain reaction; removing any one component extinguishes the fire.
PASS technique for fire extinguisher operation
Pull the pin; Aim low, pointing the nozzle at the base of the fire from 6-8 feet away; Squeeze the trigger slowly and evenly; Sweep the nozzle from side to side until the fire is extinguished.
Class B fire extinguisher
Labeled with a red square; used on fires involving flammable and combustible liquids such as gasoline, alcohol, diesel oil, oil-based paints, lacquers, and flammable gases.
Class K fire extinguisher
Used on fires involving vegetable oils, animal oils, or fats in cooking appliances, typically in commercial kitchens; primary extinguishing agent is potassium acetate mixed with water; approved uses are recognized by a symbol of a frying pan on fire.
If a fire originates within a resident's own high-rise apartment, what is the primary recommended sequence of actions according to the Chicago Fire Department guidelines?
Immediately exit the apartment, close the door, use the stairs to reach safety, and then call 9-1-1.