1/36
Vocabulary practice flashcards covering steam boiler principles, firetube and watertube designs, fittings, safety valves, blowdown equipment, and operational standards.
Low Pressure Steam Boiler
A steam boiler having a maximum allowable working pressure (MAWP) of up to 15psi.
Boiler Horsepower
The evaporation of 34.5lb of water per hour from and at a feedwater temperature of 212∘F.
Firetube Boiler
A boiler in which heat and gases of combustion pass through the tubes surrounded by water, characterized by a large volume of water relative to horsepower size.
Horizontal Return Tubular (HRT) Boiler
A specific design of firetube boiler.
Heating Surface
The part of a boiler that has heat and gases of combustion on one side and water on the other side.
Thermal Efficiency
The ratio or comparison of heat supplied in fuel to heat absorbed by boiler water.
Baffles
Partitions designed to direct combustion gases into close contact with the boiler heating surface.
Dished Heads
Concave steam and water drum ends that eliminate the need for stays.
Waterwalls
Tubes arranged along furnace walls in watertube boilers to increase the service life of furnace refractory.
Tensile Stress
The type of mechanical stress to which boiler plates and staybolts are subjected when the boiler is pressurized.
Safety Valve
The most important boiler fitting, designed to pop open to prevent internal pressure from exceeding the MAWP.
Superheater Safety Valve
A safety valve set to open before the main steam safety valves open to maintain steam flow and protect the superheater tubes from burning out.
Accumulation Test
A test conducted on a boiler to determine and verify the relieving capacity of its safety valve.
Relieving Capacity
The measure of a safety valve's discharge rate, expressed in pounds of steam per hour capable of discharging under a specified pressure.
Water Column
A vessel whose primary purpose is to reduce turbulence in the gauge glass to provide an accurate reading of the water level.
Try Cocks
Valves installed on the water column providing a secondary means of determining boiler water level.
Whistle Valve
An audible warning valve on the water column that alerts the operator to a high or low water condition.
Steam Siphon
A bent loop of pipe that traps water to protect the steam pressure gauge from direct contact with high-temperature steam.
Hydrostatic Head of Water
The pressure exerted at the base of a vertical column of water, equal to 0.433psi per vertical foot.
Boiler Vent
A fitting at the highest part of the steam side of the boiler, left open during warm-up until internal pressure reaches 10psi to 15psi.
Steam Separator
A device designed to separate water from steam by abruptly changing the direction of steam flow.
Dry Pipe
A separator device installed in the upper part of the steam and water drum.
Cyclone Separator
A drum internal used in boilers equipped with superheaters to remove moisture from steam using centrifugal force.
Saturated Steam
Steam that exists at its corresponding saturation temperature and pressure.
Superheated Steam
Steam whose temperature has been increased without an increase in pressure.
Soot Blower Supply Line
A steam piping line connected to the superheater outlet header to supply moisture-free steam to the soot blowers.
OS&Y Gate Valve
An outside screw and yoke gate valve required as a main boiler stop valve because it offers no restriction to the flow of steam.
Automatic Nonreturn Valve
A main stop valve approved by the ASME code that must be installed as close to the boiler shell as practical on the main steam line.
Free-Blowing Drain
A drain opened during boiler warm-up to remove condensate trapped between the two main steam stop valves.
Expansion Bends
Loop-shaped pipe arrangements that allow the boiler main steam line to expand and contract freely during normal usage.
Bottom Blowdown Valves (High Pressure)
Two bottom blowdown valves required by ASME code on boilers operating at 100psi or higher.
Quick-Opening Blowdown Valve
A bottom blowdown valve positioned between the boiler shell and the slow-opening valve that is opened first and closed last during blowdown.
Maximum Blowdown Line Size
The maximum permissible pipe diameter for bottom and surface blowdown lines, established at 221 in..
Mud Drum
The lowest water-side component of a watertube boiler where bottom blowdown lines are connected.
Boiler Water Analysis
The chemical assessment used as the most accurate means of establishing boiler blowdown frequency.
Surface Tension (Boiler)
The tension of the water surface in the steam and water drum, which is increased by impurities floating on the water.
Blowdown Tank
A holding vessel designed to lower temperature and pressure from boiler blowdown lines before discharge to sewer lines.