luminaire
a complete lighting unit that includes the light source, optical and electrical components, and housing
lamp designation
the letter indicates the lamp shape, and the number indicates the nominal diameter in eighths of an inch. For example, T8 has a nominal diameter of 8/8 = 1 inch.
Incandescent Lamp Source
Electric current heats a tungsten filament until it glows.
Fluorescent Lamp Source
Electrical discharge generates UV; a phosphor converts UV to visible light. A ballast starts the lamp and limits current.
LED Lamp Source
Current through a semiconductor emits light. Efficient blue LEDs with phosphors enabled practical white LED lighting.
Luminous efficacy
luminous flux (lumens) ÷ power input (watts)
Lighting power density
LPD = total installed lighting watts / floor area (W/ft²)
Solve for LPD given 8 fixtures and 60 W
8 fixtures × 60 W = 480 W; 480 W ÷ 800 ft² = 0.60 W/ft².
Illuminance Point method
E=Luminous Intensity/Distance² . If the angle is landing on a horizontal surface multiply by cos. if angle is landing on a vertical surface multiply by sin.
Number of luminaires using lumen method
Solve for N!! If the result is not a whole number, round up to the next whole luminaire!!
Manual control
A person adjusts the lighting using a switch, dimmer, or control panel
Occupancy control
The lighting responds to whether the space is occupied
Daylight control
The lighting adjusts in response to available daylight
Time control
The lighting changes according to a programmed schedule
Scene/preset control
A selected preset changes multiple lighting settings at once
Reflected Ceiling Plan (RCP)
shows the ceiling as if it were reflected onto a mirror placed on the floor
Outdoor lighting
should provide appropriate visibility and safety while minimizing unwanted light and environmental impacts. Common forms of unwanted light include uplight directed into the night sky, light trespass extending beyond the intended area, and glare that causes discomfort or reduces visibility.
Proper fixture direction and shielding
help control light pollution.
Higher illuminance
does not necessarily improve visibility and may increase glare.
CRI
describes color rendering and does not by itself indicate the level of light pollution.
Unnecessary nighttime lighting
may disturb nocturnal wildlife
Window-view quality
depends on what can be seen, how much of it is visible, and how clearly it can be seen.
window View content
The features visible through the window, such as the sky, vegetation, buildings, or activity.
window View access
The amount of the outdoor view visible from a particular position.
window View clarity
How clearly the view can be seen through glazing, shades, or other obstructions.
Sound in air
a longitudinal wave of compressions (higher pressure) and rarefactions (lower pressure).
Frequency
cycles per second (Hz)
wavelength
distance between corresponding points of successive waves.
Sound power
Total acoustic energy emitted per second, W.
Sound intensity
Power flow per unit area, W/m².
Sound pressure
Air pressure fluctuation, Pa.
Reflection
returns sound to the room
absorption
takes sound energy into a material
transmission
passes sound through a partition
RT60
the time for a sound level to drop by 60 dB after the source stops