The room temperature in an OR should be:

Between 68 and 76

2
New cards

The most effective projection from the radiation of x-rays is a:

Lead apron

3
New cards

It is considered good technique to:

Handle the mask only by strings

4
New cards

Electrical cords should be:

Removed from pathways so equipment is not rolled over them

5
New cards

Scatter radiation effects are diretly related to:

A break in the lead apron

6
New cards

Room temperature for infants and children should be maintained as warm as:

85F

7
New cards

Areas needing cleaning attention on a weekly basis include:

Air vents and heating ducts, mounted lighting racks, ceilings, walls

8
New cards

A glass suction bottle should ideally be:

Cleaned with a disinfectant solution and autoclaved before reuse

9
New cards

Storage shelves must be cleaned with a germicide:

Each week

10
New cards

While a surgical case is in progress:

Doors should remain closed

11
New cards

When cleaning the floor between cases for routine decontamination, the procedure is:

To use a disinfectant and wet vacuum

12
New cards

If a sterile item falls to the floor:

It may be used immediately only if the wrapper has no implosion holes and the floor is clean and dry

13
New cards

The following comply with the protocol for protective eyewear EXCEPT:

Prescribe eyeglasses

14
New cards

Which statement regarding OR attire is true?

Head caps and hoods must be worn to reduce contamination from hair and danger onto field; long sleeve, nonsterile cover jackets are worn by nonsterile personnel to prevent contamination by bacterial shedding of their arms; the scrub suit is worn by both sterile and non sterile personnel

15
New cards

All of the following statements are true in preparing nonsterile equipment EXCEPT:

Arrange the room according to how the ST likes it

16
New cards

All are recommendations for opening a case EXCEPT:

Open the scrub gown on the back table

17
New cards

Excessive exposure to radiation can affect the:

Reproductive organs

18
New cards

Radiation exposure of the staff is monitored with:

Film badges

19
New cards

During a craniotomy procedure, a specialty instruments falls to the floor. The physician wants the instrument sterilized immediately (IUSS). Why is this not considered an acceptable practice?

The manufacturer guidelines are not the same for all instruments

20
New cards

An OR hazard that has been linked to increased risk of spontaneous abortion in female OR employees is exposure to:

Waste anesthetic gases

21
New cards

While using this mixture, a scavenging system is used to collect and exhaust or absorb its vapors. The mixture is called:

Methyl Methacrylate

22
New cards

How is inhalation of the laser plume best prevented?

Mechanical smoke evacuator on field

23
New cards

A Cavitron unit is used for:

Ultrasonic ablation and aspiration in tumor surgery

24
New cards

The power source for Hall’s power equipment is :

Nitrogen

25
New cards

The power source for air-powered dermatomes is:

Compressed nitrogen & air

26
New cards

Suction tubing should be processed in the following way:

Residual of distilled water in lumen, steam sterilize, tubing coiled

27
New cards

The suction tip that is right angled and is used for small amounts of fluid such as in brain surgery is:

Ferguson-Frazier

28
New cards

Which suction tip has an angle and is used in the mouth or throat?

Yankauer

29
New cards

A tourniquet is used in the OR to:

Minimize blood loss during the surgical procedure; procedure a bloodless field and better visualization of the surgical site

30
New cards

Exsanguination of a limb before tourniquet inflation is accomplished with wrapping the elevated extremity with:

Esmarch

31
New cards

The amount of pressure used to inflate a tourniquet depends on all of the following EXCEPT:

Depth of surgical incision

32
New cards

A regional block that used the tourniquet is a/an:

Bier block

33
New cards

The tourniquet is contraindicated if:

Patient’s circulation to distal part of extremity is poor

34
New cards

At what point should the surgeon be informed of the time of tourniquet application?

After 1 hour, then every 15 minutes

35
New cards

When would the use of Esmarch be contraindicated?

Patient has had recent injury or recent cast

36
New cards

Which agent or power source is NOT used with the pulse lavage irrigator

Oxygen

37
New cards

A precaution necessary when using a pneumatic tourniquet is:

Solutions must be prevented from pooling under tourniquet

38
New cards

In which procedure would a tourniquet be contraindicated?

Gangrenous toe amputation

39
New cards

All of the following statements regarding a grounding plate for electrosurgery are true EXCEPT:

The plate must be placed directly over a bony prominence

40
New cards

A grounding pad is not required for the electrocautery in:

A bipolar unit

41
New cards

The inactive electrode of the cautery is the:

Grounding pad

42
New cards

The electrical circuit of the electrocautery is complete when:

Current flows from the generator to active electrode, through tissue, and back to generator via the inactive electrode

43
New cards

Why must the electrocautery tip be kept clean?

To ensure electrical contract effectiveness

44
New cards

In electrosurgery, “buzzing” refers to;

Coagulation of vessel via a metal instrument touching the active electrode

45
New cards

Which electrosurgical unit provides precise control of the coagulated area?

Bipolar

46
New cards

Which condition is MOST acceptable when using electrocautery?

Ground pad placed close to operative site

47
New cards

When using the phacoemulsifier:

The machine uses cavitation; aspirated fluids are replaced with irrigation of balanced salt solution to maintain the anterior chamber

48
New cards

A cautery would not be used:

In neck or nasopharynx surgery if nitrous oxide is used

49
New cards

Why are only moist sponges utilized during electrocautery use?

To prevent fire

50
New cards

Fulguration via the resectoscope is accomplished by the use of a/an ______ tip.

Electrode

51
New cards

Fiberoptic lighting is:

A cool light

52
New cards

All are precautions when handling fiberoptic cables EXCEPT:

Light cables should be dropped or swing free when carried

53
New cards

Fiberoptic table integrity is questionable when:

dark spots are evident

54
New cards

When using a fiberoptic cable, how are burns and fires prevented?

The cable is kept away from drapes when disconnected from endoscope; Personnel should not lean on a cable end that is disconnected but is still on; The cable end is kept on a moist towel when disconnected

55
New cards

Loupes are used for:

Magnification

56
New cards

Resolving power of an operating microscope means:

The ability to discern detail

57
New cards

Which item in the optical lens system is responsible for magnification?

Oculars & Objective lens

58
New cards

The range of focal lengths of the objective lenses in the operating microscope is:

100-400mm

59
New cards

A continuously variable magnification system is afforded to the eye surgeon by the:

Zoom lens with foot control

60
New cards

The purpose of the “slit” lamp in eye surgery is:

Defining depth perception

61
New cards

The operating microscope that visually employs fiberoptics for its light source is:

Coaxial illuminators

62
New cards

Care of the microscope would include all of the following EXCEPT:

Damp dust lenses with detergent disinfection before use

63
New cards

The purpose of the beam splitter in an operating room microscope is:

Co-incide the assistant’s field of view with the surgeon’s

64
New cards

The colpomicroscope affords a view of the:

cervix

65
New cards

The procedure that uses a self-retaining laryngoscope and microscope is called a/an:

Suspension microlaryngoscopy

66
New cards

The binocular microscope provides stereoscopic vision. This refers to:

The view afforded by double eyepieces

67
New cards

Which magnifying powers are available for the microscope eyepieces:

10x, 12.5x, 16x, and 20x

68
New cards

Which procedure is inappropriate when caring for optic lenses?

Oil or fingerprints are removed by soaking in solvent for 10 minutes and drying with a cotton ball

69
New cards

The OR bed may have a metal crossbar between the two upper sections, which may be raised to elevate the:

Kidney and gallbladder

70
New cards

The smallest diameter on a French scale is a:

9

71
New cards

Which of the following is a motorized device whose action prevents venous stasis and reduces risk of deep vein clotting in high risk patients?

Sequential pneumatic compression boots

72
New cards

A blood flow detector is a:

Doppler

73
New cards

All apply to cryotherapy EXCEPT:

it uses liquid nitrogen, Freon, or CO2; The insulated probe uses extreme cold to destroy diseased tissue

74
New cards

The mobile suction unit is called:

Neptune

75
New cards

What is the all-in-one instrument used to cauterize, irrigate, and suction simultaneously?

Coblator

76
New cards

What color is the gas outlet used for oxygen?

Green

77
New cards

All pertain to laminar air flow EXCEPT:

Maintains negative pressure

78
New cards

HEPA filters remove bacterial particles that are:

larger than 0.3mm; 0.3-0.5 mm

79
New cards

HEPA filters exchange the air in the OR how many times per hour?

Btwn 20 and 25

80
New cards

All are facts regarding OR tables EXCEPT:

there is no weight limit

81
New cards

Neurosurgery attachments include EXCEPT:

Alvarado

82
New cards

Special OR tables used for spine surgery include all EXCEPT:

Fracture table

83
New cards

When is the standing stool positioned

Before the opening of the sterile field to avoid contamination

84
New cards

Chest rolls are used to:

Assist with respirations

85
New cards

Which of the following apply to electrical accidents and/or their prevention?

the most common injury to the STSR is the ESU; All electrical equipment must be grounded; always turn the electrical equipment on/off before unplugging from teh power plug

86
New cards

Staff who must remain in the OR when using ionizing radiation should maintain a distance of how many feet from the radiation beam?

At least 6 ft

87
New cards

The device used to measure cumulative radiation exposure is called a:

Dosimeter

88
New cards

A fire requires three main components. Which is NOT considered a component?

temperature

89
New cards

Proper body ergonomics include all EXCEPT:

Do not bend all the knees when lifting a heavy object