The room temperature in an OR should be:
Between 68 and 76
The most effective projection from the radiation of x-rays is a:
Lead apron
It is considered good technique to:
Handle the mask only by strings
Electrical cords should be:
Removed from pathways so equipment is not rolled over them
Scatter radiation effects are diretly related to:
A break in the lead apron
Room temperature for infants and children should be maintained as warm as:
85F
Areas needing cleaning attention on a weekly basis include:
Air vents and heating ducts, mounted lighting racks, ceilings, walls
A glass suction bottle should ideally be:
Cleaned with a disinfectant solution and autoclaved before reuse
Storage shelves must be cleaned with a germicide:
Each week
While a surgical case is in progress:
Doors should remain closed
When cleaning the floor between cases for routine decontamination, the procedure is:
To use a disinfectant and wet vacuum
If a sterile item falls to the floor:
It may be used immediately only if the wrapper has no implosion holes and the floor is clean and dry
The following comply with the protocol for protective eyewear EXCEPT:
Prescribe eyeglasses
Which statement regarding OR attire is true?
Head caps and hoods must be worn to reduce contamination from hair and danger onto field; long sleeve, nonsterile cover jackets are worn by nonsterile personnel to prevent contamination by bacterial shedding of their arms; the scrub suit is worn by both sterile and non sterile personnel
All of the following statements are true in preparing nonsterile equipment EXCEPT:
Arrange the room according to how the ST likes it
All are recommendations for opening a case EXCEPT:
Open the scrub gown on the back table
Excessive exposure to radiation can affect the:
Reproductive organs
Radiation exposure of the staff is monitored with:
Film badges
During a craniotomy procedure, a specialty instruments falls to the floor. The physician wants the instrument sterilized immediately (IUSS). Why is this not considered an acceptable practice?
The manufacturer guidelines are not the same for all instruments
An OR hazard that has been linked to increased risk of spontaneous abortion in female OR employees is exposure to:
Waste anesthetic gases
While using this mixture, a scavenging system is used to collect and exhaust or absorb its vapors. The mixture is called:
Methyl Methacrylate
How is inhalation of the laser plume best prevented?
Mechanical smoke evacuator on field
A Cavitron unit is used for:
Ultrasonic ablation and aspiration in tumor surgery
The power source for Hall’s power equipment is :
Nitrogen
The power source for air-powered dermatomes is:
Compressed nitrogen & air
Suction tubing should be processed in the following way:
Residual of distilled water in lumen, steam sterilize, tubing coiled
The suction tip that is right angled and is used for small amounts of fluid such as in brain surgery is:
Ferguson-Frazier
Which suction tip has an angle and is used in the mouth or throat?
Yankauer
A tourniquet is used in the OR to:
Minimize blood loss during the surgical procedure; procedure a bloodless field and better visualization of the surgical site
Exsanguination of a limb before tourniquet inflation is accomplished with wrapping the elevated extremity with:
Esmarch
The amount of pressure used to inflate a tourniquet depends on all of the following EXCEPT:
Depth of surgical incision
A regional block that used the tourniquet is a/an:
Bier block
The tourniquet is contraindicated if:
Patient’s circulation to distal part of extremity is poor
At what point should the surgeon be informed of the time of tourniquet application?
After 1 hour, then every 15 minutes
When would the use of Esmarch be contraindicated?
Patient has had recent injury or recent cast
Which agent or power source is NOT used with the pulse lavage irrigator
Oxygen
A precaution necessary when using a pneumatic tourniquet is:
Solutions must be prevented from pooling under tourniquet
In which procedure would a tourniquet be contraindicated?
Gangrenous toe amputation
All of the following statements regarding a grounding plate for electrosurgery are true EXCEPT:
The plate must be placed directly over a bony prominence
A grounding pad is not required for the electrocautery in:
A bipolar unit
The inactive electrode of the cautery is the:
Grounding pad
The electrical circuit of the electrocautery is complete when:
Current flows from the generator to active electrode, through tissue, and back to generator via the inactive electrode
Why must the electrocautery tip be kept clean?
To ensure electrical contract effectiveness
In electrosurgery, “buzzing” refers to;
Coagulation of vessel via a metal instrument touching the active electrode
Which electrosurgical unit provides precise control of the coagulated area?
Bipolar
Which condition is MOST acceptable when using electrocautery?
Ground pad placed close to operative site
When using the phacoemulsifier:
The machine uses cavitation; aspirated fluids are replaced with irrigation of balanced salt solution to maintain the anterior chamber
A cautery would not be used:
In neck or nasopharynx surgery if nitrous oxide is used
Why are only moist sponges utilized during electrocautery use?
To prevent fire
Fulguration via the resectoscope is accomplished by the use of a/an ______ tip.
Electrode
Fiberoptic lighting is:
A cool light
All are precautions when handling fiberoptic cables EXCEPT:
Light cables should be dropped or swing free when carried
Fiberoptic table integrity is questionable when:
dark spots are evident
When using a fiberoptic cable, how are burns and fires prevented?
The cable is kept away from drapes when disconnected from endoscope; Personnel should not lean on a cable end that is disconnected but is still on; The cable end is kept on a moist towel when disconnected
Loupes are used for:
Magnification
Resolving power of an operating microscope means:
The ability to discern detail
Which item in the optical lens system is responsible for magnification?
Oculars & Objective lens
The range of focal lengths of the objective lenses in the operating microscope is:
100-400mm
A continuously variable magnification system is afforded to the eye surgeon by the:
Zoom lens with foot control
The purpose of the “slit” lamp in eye surgery is:
Defining depth perception
The operating microscope that visually employs fiberoptics for its light source is:
Coaxial illuminators
Care of the microscope would include all of the following EXCEPT:
Damp dust lenses with detergent disinfection before use
The purpose of the beam splitter in an operating room microscope is:
Co-incide the assistant’s field of view with the surgeon’s
The colpomicroscope affords a view of the:
cervix
The procedure that uses a self-retaining laryngoscope and microscope is called a/an:
Suspension microlaryngoscopy
The binocular microscope provides stereoscopic vision. This refers to:
The view afforded by double eyepieces
Which magnifying powers are available for the microscope eyepieces:
10x, 12.5x, 16x, and 20x
Which procedure is inappropriate when caring for optic lenses?
Oil or fingerprints are removed by soaking in solvent for 10 minutes and drying with a cotton ball
The OR bed may have a metal crossbar between the two upper sections, which may be raised to elevate the:
Kidney and gallbladder
The smallest diameter on a French scale is a:
9
Which of the following is a motorized device whose action prevents venous stasis and reduces risk of deep vein clotting in high risk patients?
Sequential pneumatic compression boots
A blood flow detector is a:
Doppler
All apply to cryotherapy EXCEPT:
it uses liquid nitrogen, Freon, or CO2; The insulated probe uses extreme cold to destroy diseased tissue
The mobile suction unit is called:
Neptune
What is the all-in-one instrument used to cauterize, irrigate, and suction simultaneously?
Coblator
What color is the gas outlet used for oxygen?
Green
All pertain to laminar air flow EXCEPT:
Maintains negative pressure
HEPA filters remove bacterial particles that are:
larger than 0.3mm; 0.3-0.5 mm
HEPA filters exchange the air in the OR how many times per hour?
Btwn 20 and 25
All are facts regarding OR tables EXCEPT:
there is no weight limit
Neurosurgery attachments include EXCEPT:
Alvarado
Special OR tables used for spine surgery include all EXCEPT:
Fracture table
When is the standing stool positioned
Before the opening of the sterile field to avoid contamination
Chest rolls are used to:
Assist with respirations
Which of the following apply to electrical accidents and/or their prevention?
the most common injury to the STSR is the ESU; All electrical equipment must be grounded; always turn the electrical equipment on/off before unplugging from teh power plug
Staff who must remain in the OR when using ionizing radiation should maintain a distance of how many feet from the radiation beam?
At least 6 ft
The device used to measure cumulative radiation exposure is called a:
Dosimeter
A fire requires three main components. Which is NOT considered a component?
temperature
Proper body ergonomics include all EXCEPT:
Do not bend all the knees when lifting a heavy object