Automatic Exposure Control (AEC)
The termination of an x-ray exposure based upon optimum x-ray energy being sensed by a solid-state detector. This is user-selectable and its accuracy is position-dependent
Device that terminates the exposure when a specific quantity of radiation has reached the image receptor (IR)
Auto-tracking
a feature of modern x-ray systems that enables simultaneous vertical movement of an upright image receptor and overhead x-ray tube
Anode
positive electrode of the x-ray tube
Bucky Mechanism
Grid that is an integral part of the x-ray table, located below the tabletop and above a cassette receptor tray. It decreases the amount of scatter radiation reaching the image receptor, & can improve image quality. It also moves during exposure so that no grid lines appear on the image
Cassette
Lightproof holder for the image receptor. It may be a computerized radiography (CR) plate or a wireless, digital radiography (DR) panel
Cathode
negative electrode of the x-ray tube
Collimator
An essential device designed to define the dimensions and direction of the x-ray beam. This device consists of four rectilinear, radiopaque blades that are adjustable to control the x-ray's field size and shape. The collimator may be operated manually or automatically
Diagnostic Yield
The amount of clinically useful, diagnostic information that is produced by a medical imaging modality
Digital Imaging
acquisition of static images in an electronic fashion to create an electronic data set; conversion of images to a digital format for image manipulation, enhancement, archival, and networking; often referenced as DR (digital radiography)
Diode
Electrical component that possesses polarity with a negative and positive terminal
DR Panel
Common term for a flat-panel digital image receptor using either indirect or direct digital capture technology
Flat-Panel Detector (FPD)
type of digital detector employing amorphous silicon or selenium material bonded with thin-film transistor technology for digital image creation and amplification
Fluoroscope
device used for dynamic radiographic examinations of patient physiologic functionality; consists of an x-ray tube and image receptor, aligned with each other in an orthogonal relationship; the x-ray tube and receptor may be above or below the patient depending upon system design
Fluoroscopy
Examination by means of the fluoroscope, employing image intensification or a flat panel detector
Goniometer
Angulation scale incorporated into the x-ray tubehead assembly to indicate the degree of x-ray tube angle, relative to the image receptor
linear accelerator
A major piece of equipment used for radiation therapy to administer x-ray or electron energies in the treatment of malignant tumors
MIMPS
Acronym for Medical Image Management and Processing System; computer network for the transmission, viewing, and archival storage of medical images; often integrated into a larger hospital information system (HIS) and radiology information system (RIS); replacing the older term PACS
orthogonal
a perpendicular relationship between the x-ray beam central ray (CR) and image receptor
Overhead Tube Crane OTC/3-D Suspension
mechanical support for suspending the x-ray tube and collimator assembly from the ceiling of the radiography room
Perfusion
the flow of blood or lymphatic fluids into and out of cells as a function of cell metabolism. Perfusion is critically important for normal cell & tissue physiology as it reflects the general health of tissues and their capability to transport oxygen, nutrients, and waste products
Picture Archival and Communication System (PACS)
Computer network for the transmission, viewing, and archival storage of medical images; often integrated into a larger hospital information system (HIS) and radiology information system (RIS)
Positive Beam Limitation (PBL)
form of automatic x-ray beam collimation of field size ensuring that the x-ray exposure field is no larger than the receptor size
Postprocessing
Manipulation of medical images after they have been acquired through x-ray exposure to improve image quality and diagnostic yield
Pulsed Progressive Fluoroscopy (PPF)
A fluoroscopic mode in which the fluoroscopic milli-amperage (mA) characteristics can be modified to maintain optimum image quality at a lower radiation dose; mA traits such as pulse height, pulse width, pulse rate and pulse interval can be altered to optimize image quality
Pyrex Glass
Special type of glass that can withstand very high temperatures from the x-ray tube anode
Primary Barrier
A receptor of x-radiation that intercepts the primary beam and prevents exposure if not interlocked with the central ray of the x-ray beam. In fluoroscopy, the fluoroscopic digital panel or image intensifier tube are primary barriers.
Quantum Mottle
An undesirable image quality characteristic that shows image graininess and a loss in visual acuity; most often the result of underexposure to the receptor
Real-Time Images
images in which dynamic patient motion is visualized instantly as fluoroscopic imaging is occurring
Soft Copy
Visualization of x-ray images using a video monitor for display and interpretation
Spot Image
Equipment that permits the acquisition of static images during a dynamic fluoroscopic examination; images acquired digitally and stored electronically
Tether
electrical wire connection between a digital detector and the x-ray generator and computer
Tube Angulation
pivoting the tube at the point where it is attached to its support; measured and displayed in degrees
X-ray tube
device that produces x-rays
X-ray tube head
equipment consisting of the x-ray tube, collimator, and operator controls; permits manipulation of x-ray tube in many directions for proper positioning