1/18
Looks like no tags are added yet.
LAT trunk bending deviation: PRO causes include all of the following EXCEPT
long PRO
LAT trunk bending deviation: USER causes include all of the following EXCEPT
adequate balance
Drop-off is a gait deviation where
body moves suddenly forward over prosthesis “feel like falling in whole”
Drop off deviation: PRO causes include all of the following EXCEPT
shoe heel or heel lift too low for current PRO foot
Dorsiflexion →
Knee Flexion Moment
Drop off deviation is almost always a
PRO cause
LAT whip deviation: PRO causes include all of the following EXCEPT
Excessive ABD of hip axis
LAT whip deviation is mostly a ______ causes and can be ______.
PRO; learned walking pattern of user
Hip Hike deviation: PRO causes include all of the following EXCEPT
sufficient knee friction
Hip Hike deviation: USER causes include
Not activating knee flexion of prosthesis
ex. toe load not enough weight thru foot
‘Pistoning’ is a gait deviation where
RL moves in/out PRO
‘Pistoning’ deviation: PRO causes include all of the following EXCEPT
knee FLX is sufficient
A ‘pistoning’ deviation is almost always ___ caise
PRO
Circumduction deviation: PRO causes include all of the following EXCEPT
socket too large
Circumduction deviation: USER causes include all of the following EXCEPT
improper alignment or fitting of the prosthesis.
According to clinical recommendations for inspecting the residual limb before and after prosthetic use, when should a patient limit or discontinue wearing their prosthesis?
When localized skin redness does not disappear within 20–30 minutes, or if a blister or open wound is present
During gait observation, a patient with a lower extremity prosthesis reports feeling as though they are "falling into a hole" at the end of the stance phase as their body moves suddenly forward over the prosthesis. Which of the following alignment issues is a primary prosthetic cause of this "drop-off" deviation?
The socket has been placed too far anterior relative to the foot (or there is excessive dorsiflexion)
Which of the following statements accurately reflects the principles of sock management and troubleshooting socket fit?
Residual limb volume decreases over time due to atrophy, requiring ply socks (which must be pulled completely smooth without wrinkles) to fill socket space
A patient ambulating with a transfemoral prosthesis demonstrates lateral trunk bending toward the prosthetic side during the stance phase. Which of the following prosthetic factors can cause this specific deviation?
Insufficient support by the lateral socket wall or a medial socket wall that is too high