What is the typical frequency range of ultrasound transducers used in veterinary medicine?
10-100 Sv
10-50 Gy
0.5-2.0 mm
< 10 cm
2.5-12 MHz
2.5-12 MHz
Which choice is an example of negative contrast media used in radiographic studies?
Iohexol
Air
Barium Sulfate
Diatrizoatel
Iothalamate
Air
An eight-year-old female spayed Labrador retriever is presented for a recent onset of seizures and behavior change. A brain tumor is suspected. Which imaging modality will provide the most information about this patient?
Computed tomography scan
Magnetic resonance imaging
Nuclear scintigraphy
M-mode ultrasound with Doppler
Radiography and myelogram
Magnetic resonance imaging
What is the main reason for clipping hair before an ultrasound procedure?
To decrease sound reflection
To decrease scattering
To increase wave refraction
To avoid damage to the transducer
To increase beam absorption
To decrease sound reflection
Which artifact is expected when performing a urinary bladder ultrasound of a dog with uroliths?
Duplication of the image distal to the urinary bladder
Dark region deep to the urolith
Echogenic bands parallel to the bladder wall
Area of hyperechogenicity beneath the stone
They do not cause an artifact
Dark region deep to the urolith
Which choice is the standard image format for medical image generation and storage?
DICOM
EIGRP
ADSL
HTTPS
NVRAM
DICOM
Which one of the following choices is the preferred imaging modality for the brain and spinal cord?
Radiography
Contrast computed tomography (CT)
Magnetic resonance imaging (MRI)
Diagnostic nuclear medicine
Ultrasonography
Magnetic resonance imaging (MRI)
What does a personal dosimeter measure?
An individual’s occupational radiation exposure
Number of radiographs taken in twenty-four hours
The patient’s radiation dose during a computed tomography scan
Radiation required to generate an image
Ionizing radiaiton present in the hospital environment
An individual’s occupational radiation exposure
When taking a radiograph, what does changing the kVp affect?
Duration of exposure
How far away to position the patient
Quantity of electrons
Penetration of x-rays
Intensity
Penetration of x-rays
Which ultrasound artifact occurs when ultrasound hits gas and is described as a "comet tail" with set of bright parallel lines?
Through-transmission
Mirror image
Refraction
Acoustic enhancement
Reverberation
Reverberation
Which of the following ultrasound transducers would be most appropriate to image an equine abdomen?
Low frequency
A-mode
M-mode
Linear array
High frequency
Low frequency
For body parts less than 10-cm thick (e.g., small animal distal limb) we use the table top technique to get the best radiographic image.
Table top technique means taking a radiographic cassette out of the bucky tray and placing it on top of the table, directly beneath the leg.
What is an important adjustment to make to get a good table top radiograph?
Use a smaller, rare-earth cassette
Increase the mAs by 15%
Decrease kVp by 10%
Move tube head further away
Add an intensifying screen under the animal
Move tube head further away
A diagnostic radiographic study of a body region should include at least two images. What is the relationship between these two images?
One with legs forward and one with legs flexed
One laying down, one standing
Right angle to the axis of first image
Opposite sides of the image
Two films taken 10-15 kVp apart
Right angle to the axis of first image
In regards to radiation exposure, which of the following would be an example of accessory equipment?
Sand bags
Sedation
Bucky tray
Calipers
Lead apron
Sand bags
Which factor has the greatest influence on radiographic contrast?
Focal-film distance
kVp
Scatter radiation
mAs
Humidity of film storage area
kVp
In radiology, foreshortening artifact results from which one of the following choices?
The structure being radiographed is not in contact with the table
The x-ray beam is more intense at the cathode side compared to the anode side
The kilovoltage (kVp) is too low
Taking a second radiograph too soon after one that required a very high exposure
The structure being radiographed is not in contact with the table
Which of the following structures can cause the ultrasound artifact known as acoustic shadowing?
Lungs
Normal gall bladder
Uroliths
Spleen
Heart muscle
Uroliths
Stationary anode radiology machines are used for which one of the following kinds of procedure?
Magnetic resonance imaging (MRI)
Contrast studies
Fluoroscopy
Computerized tomography (CT)
Dental imaging
Dental imaging
Which one of the following objects will create an artifact on a radiograph?
Movable grid
Foam wedges
Debris on hair coat
Tape that is out of the primary beam
V-shaped positioning trough
Debris on hair coat
What is an example of a soluble nonionic radiopaque contrast material?
Barium sulfate
Air
Iohexol
Iothalamate
Diatrizoate
Iohexol
What information is legally required on a radiograph identification label?
Patient signalment (age, breed, sex)
Body part being radiographed
Right or left marker
Name of radiologist performing image interpretation
Owner and patient identification
Owner and patient identification
What is a Potter-Bucky diaphragm?
Shield protecting the end of an endoscope
Canine birth control device
Moveable x-ray grid
Anesthetic gas filter
Ultrasound focusing element
Moveable x-ray grid
How is the thickness of a specific body part determined before taking radiographs in small animal veterinary medicine?
Micrometer
Callipers
Sliding scale
Technique chart
Tape measure
Callipers
When marking a thoracic radiographic film for an animal positioned right side down, what marker is used?
Right
Dorso-ventral
Oblique
Anteriopalmer
Down side is generally not marked
Right
In digital radiography, which one of the following choices best describes planking artifact?
Disappearance of the soft tissues surrounding bone
Linear striations in the background of the image
A non-uniform appearance of the image
An image with a diffuse grainy appearance
A lucent halo surrounding a metal implant
Linear striations in the background of the image
Which one of the following choices best describes the use of teleradiology?
Movement of digital images from one computer to another within a hospital
Reconstruction of 2-dimensional digital radiographs into 3-dimensional images
Conveyance of digital images from the x-ray unit detector plate to a computer monitor
Transmission of digital data between hospitals via the internet
Transfer of digital images onto film for archiving purposes
Transmission of digital data between hospitals via the internet
Which choice most directly affects the darkness (radiographic density) of a radiograph?
Thickness of the body part
Focal-film distance
Low-energy transformer
Cassette screen
Milliampere-seconds
Milliampere-seconds
What is the main difference between direct and indirect digital radiology systems?
No light intermediate with indirect systems
With direct systems, a light flash is registered to an electrical signal
Indirect systems use a scintillation x-ray detector plate
Direct systems use a photostimulable storage phosphor in a protective cassette
Direct systems are wireless, indirect are not
Indirect systems use a scintillation x-ray detector plate
If you take an x-ray of a dog at 300 milliamperes for 1/20th of a second, how many millliampere-seconds is the exposure?
600 mAs
20 mAs
15 mAs
Need more information
60 mAs
15 mAs
Which tissue is likely to produce an ultrasound reverberation artifact described as a "comet tail" (a.k.a. "B-lines") with sets of bright parallel lines?
Prostate
Liver
Lungs
Gallbladder
Urinary bladder
Lungs
What type of personal protective equipment is required when using a portable radiology machine?
Steel-toed boots and coveralls
Lead apron and gloves
Latex hand covers and lab coat
Lead goggles and full face shield
Topical zinc face cream and Tyvek® suit
Lead apron and gloves
Abdominal radiography would be most useful for which of the following possible causes of colic in a 1000-pound adult horse?
Epiploic foramen entrapment
Cecal impaction
Large colon displacement
Duodenitis/proximal jejunitis
Enterolithiasis
Enterolithiasis
What is the main source of radiation exposure for technicians manually restraining patients for radiography?
Use of a grid
Misaligned electrons
Scatter radiation
The heel effect
X-ray tube leakage
Scatter radiation
Which setting is better for an x-ray of an area of the body that has high contrast between tissue and bone, such as a hip x-ray of a young dog?
Low kilovoltage (kVp); Low milliamp-seconds (mAs)
Low kilovoltage (kVp); High milliamp-seconds (mAs)
High kilovoltage (kVp); Low milliamp-seconds (mAs)
High kilovoltage (kVp); High milliamp-seconds (mAs)
Low kilovoltage (kVp); High milliamp-seconds (mAs)
In digital radiography, which one of the following artifacts results from taking a second radiograph too soon after one that required a very high exposure?
Uberschwinger artifact
Heel effect
Ghost image
Foreshortening
Elongation
Ghost image
Radioactive iodine (I-131) is used to treat which condition?
Hyperthyroidism
Immune-mediated hemolytic anemia
Fanconi's
Diabetes mellitus
Hyperadrenocorticism
Hyperthyroidism
Which choice controls the penetrating ability of an x-ray?
Low-energy transformer
Milliampere-seconds
Kilovoltage
Cassette screen
Kilovoltage
For what reason is an aluminum filter inserted into the portal of an x-ray tube in the path of the primary beam?
Decrease scatter
Increase photon power
Minimize heel effect
Improve collimation
Reduce soft radiation
Reduce soft radiation
What is the maximum permissible dose of radiation a person is allowed to receive over a specified time from occupational exposure?
5(N + 18) rem
1(N - 18) rem
This has not been determined
5 rem/year
1.2 rem/year
5 rem/year
If you double the focal-film distance between an x-ray source and the x-ray cassette, what happens to the x-ray beam intensity on the x-ray cassette?
It is increased four-fold
No difference
It is doubled
It is halved
It is one-quarter
It is one-quarter
In addition to patient movement, which one of the following choices may cause a radiograph to come out blurry?
Poor film-screen contact
Kilovoltage too high
Static electricity
mAs too low
Focal film distance too short
Poor film-screen contact
Which choice correctly includes the key components of a radiographic exposure?
Filament temperature; photon dispersion; exposure time
Focal-film distance; milliampere-seconds; kilovoltage
Grid scatter; rotor speed; angle of tungsten target
Potter-Bucky diaphragm; cassette thickness; tissue density
Tissue thickness; energy spectrum of x-ray beam; grid ratio
Focal-film distance; milliampere-seconds; kilovoltage
What does ALARA refer to in regards to radiation exposure?
Retracting skin and fat
Increase in kVp needed when using a bucky tray
The milliampere-seconds (mAs)
Level of radiation exposure
Scatter measured one foot from the primary beam
Level of radiation exposure
Which choice is the best way to dispose of chemicals after cleaning an automatic radiographic processor?
Through a certified disposal service
Poured down the drain
Evaporation; commonly used developer chemicals break down to water, carbon dioxide, and organic compounds
Add to cat litter, then place in the regular garbage
Spread outside over well-drained soil or gravel
Through a certified disposal service
Which type of ultrasound probe is most useful for deeper tissue, far-field visualization?
B mode
M mode
Sector
Linear
10 mHz
Sector
What is the effect of a high-ratio grid on an x-ray exposure?
Less mAs needed
More x-rays pass through to the animal
Fewer X-rays reach the film
Darker x-rays
Loss of film resolution
Fewer X-rays reach the film
In ultrasound, which type of transducer probe is most useful to visualize near-field tissues?
Sector
3 mHz
Linear
M-mode
A-mode
Linear
What does an overexposed radiograph look like?
Very white
Speckled
Very dark
Foggy
Transparent
Very dark
What needs to be identified on every radiograph in addition to the patient and clinic names?
Time of day
Species
kVp used
Type of film
Patient position
Patient position
In regards to clinical radiology, when do genetic changes caused by radiation exposure typically occur?
Accumulated over 6 months
Within days to weeks
Future generations
1-5 years
Immediately
Future generations
Fluoroscopy is useful to help diagnose which one the following conditions?
Lung lobe torsion
Bile duct obstruction
Tracheal collapse
Pericardial effusion
Renal dysplasia
Tracheal collapse
What frequency transducer is most commonly used for most small animal ultrasound exams performed on animals weighing less than 15 kg?
7.5 mHz
2.25 mHz
15 mHz
12 mHz
1.0 mHz
7.5 mHz
A dog is positioned in dorsal recumbency for abdominal radiographs. Which body surface does the x-ray beam hit first?
Cranial
Lateral
Anterior
Dorsal
Ventral
Ventral
For which disorder is M-mode ultrasonography mostly used?
Transitional cell carcinoma of the bladder wall
Stomach foreign body
Splenic hemangiosarcoma
Cardiomyopathy
Renal disease
Cardiomyopathy
What shape is the image that is produced on the computer screen when using a linear array ultrasound transducer?
Rectangular
Diagonal
Triangular
Oval
Circular
Rectangular
Which of the following choices improves technician radiation safety?
Wearing a face mask and latex/nitrile gloves
Using a grid to decrease scatter radiation
Increased distance from the primary beam
Switching to a digital radiography system
Regularly examining the x-ray detector for damage
Increased distance from the primary beam
What is the best way to arrive at a specific mAs (milliamperage x time in seconds) to minimize motion blur when taking a radiograph?
Low milliamperage and short exposure time
High milliamperage and long exposure time
High milliamperage and short exposure time
Changing mAs does not affect motion blur
Low milliamperage and long exposure time
High milliamperage and short exposure time
Which group of people should be excluded from taking radiographs?
Technicians
Clients
Veterinarians
New hires in their probationary period
Anyone not licensed through OSHA
Clients
A 13-year-old male neutered King Charles Cavalier spaniel has a suspected brain tumor.
What would be the best imaging modality for this lesion?
Fluoroscopy
Magnetic resonance imaging
M-mode ultrasound with Doppler
Contrast radiography
Nuclear scintigraphy
Magnetic resonance imaging
What is a major advantage of digital radiography (DR) and computed radiography (CR) over traditional film-screen systems?
Images can be manipulated to adjust contrast and magnification
Less radiation is used to produce an image
Technique charts are unnecessary: only one set of exposure settings is used
Radiographs can still be taken during power failures
Scatter radiation is minimal, so grids and collimation are not needed
Images can be manipulated to adjust contrast and magnification
Which of the following choices is a contraindication for the use of barium sulfate as a radiographic contrast agent?
Vomiting
Bowel perforation
Regurgitation
Diarrhea
Esophageal dilation
Bowel perforation
What is the minimum legal age in years to allow someone to encounter occupational radiation exposure?
10
25
21
18
16
18
What positioning criteria are important to remember when taking lateral chest radiographs meant to specifically evaluate heart problems in dogs and cats?
Umbilicus and entire rib cage is included
Include cervical vertebrae
Image taken at full exhalation
Extend forelegs forward, away from chest wall
Sternum needs to be superimposed over vertebrae
Extend forelegs forward, away from chest wall
Where on the body should a dosimetry badge be worn?
Under the gown, at the waist
Adjacent to reproductive organs
Back of the gown, on the body ties
Under the gown, in your scrub pocket
Front of the gown, on the collar
Front of the gown, on the collar
Which factor can cause an x-ray image to be too dark?
Low milliampere-seconds
High kilovoltage
Poor centering of the primary x-ray beam
Use of a Potter Bucky diaphragm
Increased film focal-film distance
High kilovoltage
What is the maximum permissible dose (MPD) of occupational radiation exposure an individual should have per year?
100 Gray
1 Rem
0.05 Sievert
2% kVp
1/100 Thermoluminescent units
0.05 Sievert
A ventral-dorsal (VD) chest radiograph is indicated during diagnostic workup of a dog.
Where should the x-ray beam enter the body first?
Spinous processes
Costo-chondral junctions
Umbilicus
Thoracic vertebrae
Sternum
Sternum
What type of contrast agent is typically used to make the image below?
There is no contrast agent in this image
Radiolucent gas (e.g., nitrous oxide)
Soluble ionic organic iodide (e.g., iothalamate)
Nonionic organic iodide (e.g., iohexol)
Insoluble inert radiopaque medium (e.g., barium sulfate)
Nonionic organic iodide (e.g., iohexol)

What is the most critical issue with this radiograph of a bird?
Overexposed
Improper positioning of bird
Underexposed
Human hand is in image
Poorly collimated
Human hand is in image

Which of the following monitors used to measure blood pressure detects blood flow using ultrasonic waves?
Photoplethysmograph
Pulse oximeter
Capnograph
Doppler
Oscillometric
Doppler
In what direction do electrons move in an x-ray tube when an x-ray beam is generated?
Tube window to tungsten target
Focal spot to filament
Cathode to anode
Glass envelope to focusing cup
Collimator to targeting surface
Cathode to anode
Which one of the following choices best describes how an image is produced with digital radiography?
An x-ray beam passes transaxially through a small segment of the patient; an image is created by measuring x-ray attenuation at sequential sites
Technetium 99 is administered to a patient; photon emission is detected and recorded with a gamma scintillation camera
A detector panel converts x-rays into electrical signals; an analog image is created which is then digitalized
A transducer emits a short pulse of sound into the patient; the sound that is reflected back creates an image
Radio waves are used to generate images by disrupting hydrogen nuclei in tissues
A detector panel converts x-rays into electrical signals; an analog image is created which is then digitalized
Which one of the following choices best describes the use of Digital Imaging and Communication in Medicine (DICOM) in digital radiology?
A method of obtaining digital radiographs with less radiation exposure
A means of converting traditional x-ray film into digital images
A mechanism that prevents artifacts from occurring on digital images
A universal digital image format that allows sharing of images between clinics
A technique that transforms digital images into hard copies for storage purposes
A universal digital image format that allows sharing of images between clinics
Under what conditions may the technician's hands be under the path of a primary x-ray beam when assisting in the radiology area?
Under no conditions
When the x-ray beam is collimated
When the animal is moving too much for a clear radiograph
If lead gloves are worn
If a grid is used
Under no conditions
What is the purpose of an x-ray grid?
Prevents x-ray beam scatter
Protects technician from x-rays
Increases penetrating power of the x-ray beam
Decreases mAs and kV needed for an exposure
Reduces patient exposure to radiation
Prevents x-ray beam scatter
Why are animals routinely shaved prior to having an abdominal ultrasound?
Provides visual proof to the owners
Prevents transducer gel from matting the animal's coat
Lowers the temperature of the affected tissue
Hair traps air
They should not be shaved
Hair traps air
Ionizing radiation is used to create an image in radiography.
Which one of the following choices lists another diagnostic modality that uses ionizing radiation?
Computed tomography
Ultrasonography
Bronchoscopy
Hyperbaric oxygen therapy
Magnetic resonance imaging
Computed tomography
Which kind of tissue causes the most x-ray scatter?
Joints 8 cm thick or less
Thick body parts
Thin body parts
Delicate bone, like nasal area
Thick body parts
Which of the following choices correctly defines "dosimetry"?
The magnitude of energy produced by an x-ray beam
The quantity of ionizing radiation produced by magnetic resonance imaging (MRI)
The rate of decay of a radionuclide
A measurement of personal radiation exposure
The amount of scatter radiation emitted per radiograph taken
A measurement of personal radiation exposure
What ultrasound modality is used to evaluate blood flow?
Doppler
Oscillometry
B-mode
Fluoroscopy
A-mode
Doppler
Which one of the following choices is typically anechoic (sonolucent) on ultrasound?
Urinary bladder
Liver
Spleen
Adrenal gland
Bone
Urinary bladder
Which of the following choices is synonymous with sonolucent (i.e., dark on ultrasound)?
Echoic
Anechoic
Sonotrophic
Radiodense
Hyperechoic
Anechoic
What is the correct order of radiopacity, from least to most radiopaque?
Bone-metal-water-fat-air
Water-air-fat-bone-metal
Air-fat-water-bone-metal
Metal-bone-water-fat-air
Air-water-fat-metal-bone
Air-fat-water-bone-metal
A ten-year-old, obese Dachshund is presented with a week-long history of rear leg ataxia suggestive of a possible intervertebral disc problem.
A full series of ventro-dorsal (VD) and right lateral spinal films are needed to evaluate bony structures as a preliminary diagnostic step.
What positioning criteria are important to remember to optimize vertebral image quality in the lateral thoracic views?
Oblique view is preferable if right side is down
Avoid chest rotation
Extend forefeet cranio-dorsally towards chin
Sternum should be visible
Label the left side
Avoid chest rotation
Focal-film distance is the distance between which two objects?
Dorsal and ventral aspect of the structure being radiographed
Cathode and the anode
Bottom of the x-ray tube and the floor
Glass envelope and the filament
Tungsten target and surface of the x-ray detector
Tungsten target and surface of the x-ray detector
What is the definition of radiographic contrast?
Degree of overlap
Image clarity at the edge of anatomic structures
Visible difference between adjacent structures
Level of darkness
Sharpness of the tissue borders
Visible difference between adjacent structures
Which one of the following choices correctly defines what a unit of Gray (Gy) measures in radiology?
Absorbed dose of ionizing radiation by a unit mass of material
Distance between target in x-ray tube and surface of the x-ray detector
Quantity of x-ray photons produced by anode
Degree of echogenicity in an ultrasound image
Energy produced by x-ray beam
Absorbed dose of ionizing radiation by a unit mass of material
Which type of ultrasound transducer is used for transrectal examination in horses?
Broad bandwidth
Phased array sector
Linear array
Concave
Mechanical sector
Linear array
What is the principal disadvantage of using a grid while taking a radiograph?
Longer exposure time required
Cannot use with body parts over 10 cm thick
Decreased resolution
Visible gridlines distort the radiograph
A grid will increase the amount of scattered radiation
Longer exposure time required
What does an underexposed radiograph look like?
Foggy
Very light
Speckled
Transparent
Too dark
Very light
Which of the following would be a clinical presentation that might best be imaged using fluoroscopy?
Regurgitation
Osteomyelitis of cervical vertebra
Tibial fracture
Interstitial pneumonia
Paranasal sinusitis
Regurgitation
When you position a dog for a lateral pelvic radiograph, where do you measure the dog and where do you center the x-ray beam?
Over the acetabulum, greater trochanter of the femur
Across the sacrum, first two coccygeal vertebrae
Ischial tuberosities, base of tail
Wings of the ilium, caudal portion of the pubic foramen
Over the acetabulum, greater trochanter of the femur
As you look closely at an abdominal radiograph from a large German Shepherd, you see many regularly spaced alternating light and dark lines on the radiograph.
What do these lines mean?
The kilovoltage was too high
This is a sign of static electricity
The focal-film distance was too long
The x-ray was shot through a Potter-Bucky diaphragm
The x-ray was shot with a grid under the dog
The x-ray was shot with a grid under the dog
What is the purpose of the collimator in an x-ray machine?
Maintains a vacuum environment
Removes less-energetic x-rays from primary beam
Decreases production of scatter radiation
Prevents beta radiation from reaching the film
Provides electricity needed to heat the filament
Decreases production of scatter radiation
What are the three most important factors to remember for radiation safety?
kVp setting, focal-film distance, grid type
Collimation, speed, and megahertz
Positioning, angle of tungsten target, temperature of filament
Time, distance, shielding
Power, restraint, x-ray tube length
Time, distance, shielding
Which of the following correctly describes the Uberschwinger artifact (also known as the rebound effect) in digital radiography?
X-ray beam is more intense on cathode side than anode side
Image appears grainy due to underexposure
Linear striations are seen in background of image
Radiolucent halo around metal implants
Images from a previous exposure stay on panel due to high exposure
Radiolucent halo around metal implants
You have just taken an x-ray of a dog at 10 milliampere-seconds (mAs) from 100 cm away.
Now you need to reposition the dog and take another x-ray from 50 cm.
What mAs setting should you use to get a similar exposure to the first x-ray?
10 mAs
5mAs
2.5 mAs
20 mAs
2.5 mAs
Which one of the following choices is a type of mechanical restraint used to position a patient for a radiograph?
Foam wedge
Lead apron
Rabies pole
Tranquilizer
Technician's hands
Foam wedge
Which one of the following choices may cause a radiograph to come out blurry?
Patient movement
Focal-film distance too short
mAs too high
kVp too low
Static electricity
Patient movement
What is an anticlinal vertebra?
Anatomic landmark
First vertebra after sacrum
Congenital vertebral anomaly
Alternate name for C1
Transitional vertebra between thoracic and lumbar spine
Anatomic landmark