1/60
Looks like no tags are added yet.
What is the optimal time temperature, and pressure settings used for sterilization in an autoclave machine?
20 mins, 121 degrees, 15psi
What risk group does E.Coli strain ER1647 belong to?
Risk group 1
What risk group does Lambda Bacteriophage belong to?
Risk group 1
P10 adjustable pipette
4.5 uL
Biosafety containment practices used in this lab are
Biosafety containment level I, with added biosafety containment level II practice
MSDS stands for
Material safety data sheets
To contain a biohazard spill outside of the biological safety cabinet, the following procedures are practiced
Close all open containers near spill. cover spill with paper towels, saturate paper towels with 10% bleach, discard paper towels, spray 70% Ethanol, repeat, and notify TA
P100 adjustable pipetter
55 uL
Why did we add tetracycline in our agar plates for ER1647 growth?
To grow ER1647 that are Tetracycline resistant
Steps for streaking agar plate
Flame tube, flame loop, saturate loop with bacteria, perform quadrant streaking method, flaming loop in between steps
What is the purpose of adding chloroform to the phage/SM buffer solution?
Lyses Bacterial membranes, killing the bacteria
What is the purpose of the 20 minutes at 37 degrees incubation after the Phage and Bacteria have been combined?
Adsorption and penetration of the virus
What is the dilution if you add 1uL viral sample into 9 uL of buffer?
1 uL/ 1 uL + 9uL=1/10
What is in the SM Phage buffer that allows Phage to remain viable?
Gelatin
DMSO
Dimethyl sulfoxide
What is the dilution if you add 50uL viral sample into 450uL of buffer?
50uL/ 50uL + 450uL=50/500=1/10
What is the purpose of the plaque assay?
To determine the amount of virus that are present in your original sample
We use BLANK when working with mL volumes of liquid and we use BLANK when working with uL volumes of liquid
serological pipet-aid; adjustable pipetter
To prevent water condensation overnight you would incubate your agar plates BLANK when performing the plaque assay
Inverted
BLANK is the practice of safe methods to contain and handle an infectious agent
Containment
The volume/concentration of the BLANK should never exceed the volume/concentration of the BLANK when combining phage and bacteria together
Bacteriophage; Bacteria
In order to be able to count plaques in a plaque assay we must do a BLANK of our concentrated virus before incubating it with bacteria
Serial dilution
PFU is an acronym for BLANK
Plaque forming units
We incubated our Phage and ER1647 bacteria mixture for BLANK minutes, at BLANK C
20; 37
A chemical BLANK is a substance of biological origin
Chemical
BLANK is the cryoprotectant that is used for freezing phage stocks
30% glycerol
BLANK is the cryoprotectant that is used for freezing E. coli stocks
7% DMSO
How will you prepare a 100 ml of 2% gelatin solution with water?
2% of 100 ml= 2ml gelatin
100 ml - 2= 98 ml water
How much maltase powder do you need to make a solution of 1L of LB media where the concentration of maltose powder will be 0.2%?
1L=1000 mL
(0.2g/100mL) x 1000mL=2g
Determine the volume of tetracycline needed to add in 1L of LB media where the tetracycline concentration will be 12.5 ug/mL, using the tetracycline stock which concentration is 12.5mg/ml.
C1=12.5ug/mL
C2=12.5 × 1000=12500
V2= 1L= 1000mL
V1=(12.5)(1000)/12500=1 ml
How much MgSO4 powder do you need to make a 100 ml of LB media where the concentration of MgSO4 will be 10 mM? (Molar mass=120.37 g/mol)
100 mL/1000 mL/L= 0.1L
10 mL/1000 mM/M=0.01 M
(0.01 mol/L)(0.1 L)(120.37 g/mol)=0.12037 g
Calculate the concentration of viral stock from the following plaque formations
PFU=10
DF=10-5
Volume=500 uL=0.5 mL
Concentration=10/0.5 × 10-5
10/0.5=20
1/10-5=105
(2.0 × 101) x 105=2.0 × 106 PFU/mL
DMSO
Protects from freezing
Chloroform
Kills bacteria without killing the phage
SM phage buffer
Pulls water out of the concentration
Glycerol
Used as a freezing agent to prevent ice-crystals forming
E coli
Gram negative bacteria found in digestive tract
What is the principle of plaque assay?
To determine the original amount of viruses, present in an original stock
4 types of adjustable pipettors
P1000-100; 1000
P200-20; 200
P20-2; 20
P10-0.5; 100
Names of disinfectants used in lab
10% bleach
70% Ethanol
Steps to prepare the biosafety cabinet for culturing cells aseptically
1.) Aseptic technique and standard safety practices.
2.) Protective gear must be worn.
3.) All materials needed for the experiment must be in the cabinet prior to starting, to minimize movement
in and out of the cabinet.
4.) The front and back grills should never be blocked.
5.) Work area should be clutter-free.
6.) Personnel should work at a distance greater than 4 inches within the Class II cabinets. Currents that are created by working close to the inlet grill can allow for back-flow of contaminated air out of the hood.
7.) Traffic in front of the cabinet should be restricted when a cabinet is in use to avoid sudden drafts, which can disrupt the airflow barrier of the cabinet and prevent distraction for the worker.
8.) Provisions must be made for the safe removal of decontaminated material from the cabinets.
9.) The cabinets require decontamination at the beginning and end of each experiment (10% bleach/70% ethanol)
Type of biosafety hood will be required for cell culture
Class II hood
What is the name and purpose of the exclusion dye when counting cells?
Typhan blue, it is used to differentiate between living and dead cells
Cell concentration=average # of cells x dilution factor x 104
Describe in detail how do you get 104
1 cm3=1mL
10mm3=1,000mm3
1mmm3=1/1000mL=10-3 mL
Volume=0.1mm3=0.1×10-3mL=10-4mL


The optimal growth conditions for Vero cell line are
37 C
Humidity
C02
Media-DMEM
How is the media enriched for Vero cell line?
10% FBS
What is preferred disinfectant used to decontaminate the biosafety hood PRIOR to using it?
70% Ethanol
Why do we centrifuge the cells at 1,500 rpm for 10 minutes after we have collected them from the T-75 flasks?
To concentrate the cells so they can safely aspirate and fresh medium can be placed
How do you detach cells from the flask?
Adding proteolytic enzyme solution and incubating the flask for 10 mins

Preferred disinfectant used to decontaminate biosafety hood AFTER a procedure has been preformed
10% bleach and 70% ethanol
Why do we use Hemagglutination assay?
To confirm if virus is present in sample and detect its titer
Influenza virus
contains HA antigens on its cell surface can bind to RBC and cause them to agglutinate
Baculovirus
contains viral surface protein gp46 that can also bind to RBC of host cells (via unknown receptor) and induce hemagglutination of RBC
Hemagglutination-inhibition (HAI) assay
Involve titration of the viral hemagglutination with an anti-viral antibody (often from serum of human or animal infected with that virus) for inhibition of hemagglutination (i.e. neutralization of virus)
Why do we use RBC in Hemagglutination assay?
because they have carbohydrate-containing receptors on their surface, their color acts as an indicator in the assay
HA titer
Dilution factor / volume of virus added (in mL)
End point
the last well that hemagglutinated with the viral sample
Consider a negative control with PBS and RBC only (no virus)
Why?
to eliminate any potential agglutination factors that are in the buffer, that may cause false positive results.