What is the optimal time temperature, and pressure settings used for sterilization in an autoclave machine?

20 mins, 121 degrees, 15psi

2
New cards

What risk group does E.Coli strain ER1647 belong to?

Risk group 1

3
New cards

What risk group does Lambda Bacteriophage belong to?

Risk group 1

4
New cards

P10 adjustable pipette

4.5 uL

5
New cards

Biosafety containment practices used in this lab are

Biosafety containment level I, with added biosafety containment level II practice

6
New cards

MSDS stands for

Material safety data sheets

7
New cards

To contain a biohazard spill outside of the biological safety cabinet, the following procedures are practiced

Close all open containers near spill. cover spill with paper towels, saturate paper towels with 10% bleach, discard paper towels, spray 70% Ethanol, repeat, and notify TA

8
New cards

P100 adjustable pipetter

55 uL

9
New cards

Why did we add tetracycline in our agar plates for ER1647 growth?

To grow ER1647 that are Tetracycline resistant

10
New cards

Steps for streaking agar plate

Flame tube, flame loop, saturate loop with bacteria, perform quadrant streaking method, flaming loop in between steps

11
New cards

What is the purpose of adding chloroform to the phage/SM buffer solution?

Lyses Bacterial membranes, killing the bacteria

12
New cards

What is the purpose of the 20 minutes at 37 degrees incubation after the Phage and Bacteria have been combined?

Adsorption and penetration of the virus

13
New cards

What is the dilution if you add 1uL viral sample into 9 uL of buffer?

1 uL/ 1 uL + 9uL=1/10

14
New cards

What is in the SM Phage buffer that allows Phage to remain viable?

Gelatin

15
New cards

DMSO

Dimethyl sulfoxide

16
New cards

What is the dilution if you add 50uL viral sample into 450uL of buffer?

50uL/ 50uL + 450uL=50/500=1/10

17
New cards

What is the purpose of the plaque assay?

To determine the amount of virus that are present in your original sample

18
New cards

We use BLANK when working with mL volumes of liquid and we use BLANK when working with uL volumes of liquid

serological pipet-aid; adjustable pipetter

19
New cards

To prevent water condensation overnight you would incubate your agar plates BLANK when performing the plaque assay

Inverted

20
New cards

BLANK is the practice of safe methods to contain and handle an infectious agent

Containment

21
New cards

The volume/concentration of the BLANK should never exceed the volume/concentration of the BLANK when combining phage and bacteria together

Bacteriophage; Bacteria

22
New cards

In order to be able to count plaques in a plaque assay we must do a BLANK of our concentrated virus before incubating it with bacteria

Serial dilution

23
New cards

PFU is an acronym for BLANK

Plaque forming units

24
New cards

We incubated our Phage and ER1647 bacteria mixture for BLANK minutes, at BLANK C

20; 37

25
New cards

A chemical BLANK is a substance of biological origin

Chemical

26
New cards

BLANK is the cryoprotectant that is used for freezing phage stocks

30% glycerol

27
New cards

BLANK is the cryoprotectant that is used for freezing E. coli stocks

7% DMSO

28
New cards

How will you prepare a 100 ml of 2% gelatin solution with water?

2% of 100 ml= 2ml gelatin

100 ml - 2= 98 ml water

29
New cards

How much maltase powder do you need to make a solution of 1L of LB media where the concentration of maltose powder will be 0.2%?

1L=1000 mL

(0.2g/100mL) x 1000mL=2g

30
New cards

Determine the volume of tetracycline needed to add in 1L of LB media where the tetracycline concentration will be 12.5 ug/mL, using the tetracycline stock which concentration is 12.5mg/ml.

C1=12.5ug/mL

C2=12.5 × 1000=12500

V2= 1L= 1000mL

V1=(12.5)(1000)/12500=1 ml

31
New cards

How much MgSO4 powder do you need to make a 100 ml of LB media where the concentration of MgSO4 will be 10 mM? (Molar mass=120.37 g/mol)

100 mL/1000 mL/L= 0.1L

10 mL/1000 mM/M=0.01 M

(0.01 mol/L)(0.1 L)(120.37 g/mol)=0.12037 g

32
New cards

Calculate the concentration of viral stock from the following plaque formations

PFU=10

DF=10-5

Volume=500 uL=0.5 mL

Concentration=10/0.5 × 10-5

10/0.5=20

1/10-5=105

(2.0 × 101) x 105=2.0 × 106 PFU/mL

33
New cards

DMSO

Protects from freezing

34
New cards

Chloroform

Kills bacteria without killing the phage

35
New cards

SM phage buffer

Pulls water out of the concentration

36
New cards

Glycerol

Used as a freezing agent to prevent ice-crystals forming

37
New cards

E coli

Gram negative bacteria found in digestive tract

38
New cards

What is the principle of plaque assay?

To determine the original amount of viruses, present in an original stock

39
New cards

4 types of adjustable pipettors

P1000-100; 1000

P200-20; 200

P20-2; 20

P10-0.5; 100

40
New cards

Names of disinfectants used in lab

10% bleach

70% Ethanol

41
New cards

Steps to prepare the biosafety cabinet for culturing cells aseptically

1.) Aseptic technique and standard safety practices.

2.) Protective gear must be worn.

3.) All materials needed for the experiment must be in the cabinet prior to starting, to minimize movement

in and out of the cabinet.

4.) The front and back grills should never be blocked.

5.) Work area should be clutter-free.

6.) Personnel should work at a distance greater than 4 inches within the Class II cabinets. Currents that are created by working close to the inlet grill can allow for back-flow of contaminated air out of the hood.

7.) Traffic in front of the cabinet should be restricted when a cabinet is in use to avoid sudden drafts, which can disrupt the airflow barrier of the cabinet and prevent distraction for the worker.

8.) Provisions must be made for the safe removal of decontaminated material from the cabinets.

9.) The cabinets require decontamination at the beginning and end of each experiment (10% bleach/70% ethanol)

42
New cards

Type of biosafety hood will be required for cell culture

Class II hood

43
New cards

What is the name and purpose of the exclusion dye when counting cells?

Typhan blue, it is used to differentiate between living and dead cells

44
New cards

Cell concentration=average # of cells x dilution factor x 104

Describe in detail how do you get 104

1 cm3=1mL

10mm3=1,000mm3

1mmm3=1/1000mL=10-3 mL

Volume=0.1mm3=0.1×10-3mL=10-4mL

45
New cards
term image
46
New cards
term image
47
New cards

The optimal growth conditions for Vero cell line are

37 C

Humidity

C02

Media-DMEM

48
New cards

How is the media enriched for Vero cell line?

10% FBS

49
New cards

What is preferred disinfectant used to decontaminate the biosafety hood PRIOR to using it?

70% Ethanol

50
New cards

Why do we centrifuge the cells at 1,500 rpm for 10 minutes after we have collected them from the T-75 flasks?

To concentrate the cells so they can safely aspirate and fresh medium can be placed

51
New cards

How do you detach cells from the flask?

Adding proteolytic enzyme solution and incubating the flask for 10 mins

52
New cards
term image
53
New cards

Preferred disinfectant used to decontaminate biosafety hood AFTER a procedure has been preformed

10% bleach and 70% ethanol

54
New cards

Why do we use Hemagglutination assay?

To confirm if virus is present in sample and detect its titer

55
New cards

Influenza virus

contains HA antigens on its cell surface can bind to RBC and cause them to agglutinate

56
New cards

Baculovirus

contains viral surface protein gp46 that can also bind to RBC of host cells (via unknown receptor) and induce hemagglutination of RBC

57
New cards

Hemagglutination-inhibition (HAI) assay

Involve titration of the viral hemagglutination with an anti-viral antibody (often from serum of human or animal infected with that virus) for inhibition of hemagglutination (i.e. neutralization of virus)

58
New cards

Why do we use RBC in Hemagglutination assay?

because they have carbohydrate-containing receptors on their surface, their color acts as an indicator in the assay

59
New cards

HA titer

Dilution factor / volume of virus added (in mL)

60
New cards

End point

the last well that hemagglutinated with the viral sample

61
New cards

Consider a negative control with PBS and RBC only (no virus)

Why?

to eliminate any potential agglutination factors that are in the buffer, that may cause false positive results.