16 Terms

1
New cards

Data Center Certified Associate (DCCA)

An entry-level, vendor-neutral certification from Schneider Electric University focused on foundational data center physical infrastructure, including power, cooling, cabling, physical security, and management.

2
New cards

DCCA Examination Parameters

A test format featuring 100100 questions, a duration of 120120 minutes, a passing score requirement of 70%70\%, and an exam fee of 250 USD250\,\text{USD}.

3
New cards

Switchgear and Transformers

Physical distribution equipment delivering electricity from utility grid generation and transmission pathways to internal technical spaces.

4
New cards

Power Distribution Units (PDUs)

Power equipment deployed in the rack environment alongside rack-mounted power strips, redundancy paths, and dual-corded server strategies.

5
New cards

Automated Transfer Switches (ATS)

Switching devices used in conjunction with emergency backup diesel generators and fuel storage systems to transition power sources.

6
New cards

Uninterruptible Power Supply (UPS)

Critical backup power equipment operating in standby, line-interactive, or double-conversion online configurations, utilizing battery storage or flywheels.

7
New cards

Double-Conversion Online Systems

A specific Uninterruptible Power Supply (UPS) configuration studied alongside standby and line-interactive topologies.

8
New cards

Airflow Containment

The deployment of curtains and rigid panels in raised floor environments with hot/cold aisle layouts to segregate supply and exhaust air.

9
New cards

Chilled Water Systems

Large-scale chiller plant operations used to collect and reject heat while coordinating with precise relative humidity control to mitigate static risks and condensation.

10
New cards

Structured Cabling

Standardized cabling topologies employing fiber optic and copper media, along with pathway management designed to prevent airflow blockages.

11
New cards

Very Early Smoke Detection Apparatus (VESDA)

An advanced aspirating smoke detection technology used in fire detection alongside pre-action sprinkler systems and gaseous clean-agent fire suppression alternatives.

12
New cards

Pre-action Sprinkler Systems

A specialized fire suppression mechanism utilized in data centers alongside gaseous clean-agent alternatives and early detection sensors.

13
New cards

Defense-in-Depth Model

A multi-layered physical security architecture spanning external perimeters, building access points, mantrap entry gates, and biometric server rack locking controls.

14
New cards

Mantrap Entry Gates

Physical access control portals positioned between exterior facility access points and internal server spaces within a defense-in-depth security model.

15
New cards

Standard 19-inch Rack

A standardized technical enclosure geometry assessed by structural weight capacities, rail configurations, and physical space optimization tactics.

16
New cards

Data Center Infrastructure Management (DCIM)

Software platforms providing environmental monitoring, real-time sensor networking, and capacity planning metrics across physical infrastructure.