Reactor-produced radionuclides are neutron-rich and decay by

Beta-minus emission

2
New cards

Cyclotron-produced radionuclides are proton-rich and decay by

Positron emission or electron capture

3
New cards

Production method for most PET isotopes

Cyclotron

4
New cards

Two major fission products used in nuclear medicine

Mo-99 and I-131

5
New cards

Reactor process where a stable nucleus captures a neutron

Neutron activation (n,γ)

6
New cards

Neutron activation product is what element relative to the target

Same element (low specific activity)

7
New cards

Fission product is what element relative to the target

Different element (carrier-free)

8
New cards

Does a generator create new radioactivity

No, it separates daughter from parent

9
New cards

Isotopes made with 0–10 MeV hospital cyclotrons

F-18 and O-15

10
New cards

Isotopes requiring 30+ MeV cyclotrons

Sr-82 and Ge-68

11
New cards

Reaction producing F-18

O-18 (p,n) F-18

12
New cards

Reaction producing In-111

Cd-112 (p,2n) In-111

13
New cards

Parent that decays to Tl-201

Pb-201 (T½ 9.3 h)

14
New cards

Immediate parent that decays to I-123

Xe-123

15
New cards

Half-life of In-111

2.8 days (~67 h)

16
New cards

PET isotope requiring an on-site cyclotron due to its 20 min half-life

C-11

17
New cards

Reactor component that slows neutrons to thermal speed

Moderator

18
New cards

Percent U-235 in natural uranium

0.7%

19
New cards

Fission products mnemonic My I-Xe Story Can Act

Mo-99, I-131, Xe-133, Sr-90, Cs-137, Ac-227

20
New cards

Neutron activation reaction producing Lu-177

Lu-176 (n,γ) Lu-177

21
New cards

Mo-99 half-life

66 h

22
New cards

Tc-99m half-life

6 h

23
New cards

Sr-82 half-life

25 days (25.5 d)

24
New cards

Rb-82 half-life

75 seconds

25
New cards

Equilibrium type of the Mo-99/Tc-99m generator

Transient equilibrium

26
New cards

Equilibrium type of the Sr-82/Rb-82 generator

Secular equilibrium

27
New cards

Parent-to-daughter half-life ratio for transient equilibrium

~10–50 : 1

28
New cards

Parent-to-daughter half-life ratio for secular equilibrium

100 : 1

29
New cards

In transient equilibrium daughter activity compared to parent

Slightly exceeds parent, then tracks it

30
New cards

In secular equilibrium daughter activity compared to parent

Approximately equal

31
New cards

Time for Sr-82/Rb-82 to reach equilibrium

~7.5 min

32
New cards

Time to maximum Tc-99m regrowth after elution

~23–24 hours

33
New cards

Percent of Mo-99 activity present as Tc-99m at 24 h

87%

34
New cards

Column material holding Mo-99 in the generator

Alumina (Al2O3)

35
New cards

Chemical form of the Tc-99m eluate

Sodium pertechnetate (TcO4−, +7)

36
New cards

Theoretical generator yield formula

Mo activity now × Tc/Mo fraction

37
New cards

Actual generator yield formula

Theoretical yield × elution efficiency

38
New cards

Typical elution efficiency

85–95%

39
New cards

Elution efficiency with theoretical 550 mCi and actual 475 mCi

86.4%

40
New cards

Causes of low generator yield

Air leak, channeling, radiolysis

41
New cards

Purity type asking is this the right isotope

Radionuclidic purity

42
New cards

Purity type asking is there an unwanted non-radioactive substance

Chemical purity

43
New cards

Purity type asking is the isotope in the right chemical form

Radiochemical purity

44
New cards

Mo-99 breakthrough limit

0.15 µCi Mo-99 per mCi Tc-99m

45
New cards

Mo-99 breakthrough limit applies at what time

Time of administration

46
New cards

Agency setting the Mo-99 breakthrough limit (10 CFR 35.204)

NRC

47
New cards

How often Mo-99 breakthrough is tested

Every elution

48
New cards

Mo-99 gamma energies detected in the moly assay

740 and 780 keV

49
New cards

Why the lead moly shield works

Blocks 140 keV Tc, passes Mo gammas

50
New cards

Usual Tc-99m eluate expiration

~12 hours

51
New cards

Time to reach the Mo limit formula

t = ln(0.15 ÷ ratio) ÷ 0.105

52
New cards

Mo breakthrough: 18 µCi Mo in 300 mCi Tc

0.06 µCi/mCi, passes

53
New cards

Maximum Mo-99 allowed in 756 mCi Tc-99m

113.4 µCi

54
New cards

Aluminum (Al3+) breakthrough limit

10 µg/mL

55
New cards

Test used for Al3+ breakthrough

Colorimetric spot test (aurin tricarboxylic acid)

56
New cards

Al3+ spot test passes when the eluate spot is

Lighter than the 10 µg/mL standard

57
New cards

Effect of excess Al3+ on a bone scan

Liver uptake

58
New cards

Effect of excess Al3+ on sulfur colloid

Clumping, lung uptake

59
New cards

Agent in sulfur colloid kits that binds excess Al3+

EDTA

60
New cards

Rb-82 is an analog of

Potassium

61
New cards

Rb-82 generator daily QC first step

Elute 50 mL saline and discard

62
New cards

Wait time before re-eluting for Rb-82 QC

~10 minutes

63
New cards

Time the Rb-82 QC sample must decay before Sr measurement

≥1 hour

64
New cards

Sr-82 breakthrough limit

0.02 µCi Sr-82 per mCi Rb-82

65
New cards

Sr-85 breakthrough limit

0.2 µCi Sr-85 per mCi Rb-82

66
New cards

Sr-82 calculation from the decayed sample reading

Reading ÷ [1 + (R × 0.478)]

67
New cards

Sr-85 breakthrough calculation

Sr-82 result × R (Sr-85/Sr-82 ratio)

68
New cards

Rb-82 QC: 50 mCi at EOE, R 1.48, sample 0.8 µCi

Sr-82 0.0094, Sr-85 0.014; passes

69
New cards

Dose calibrator detector type

Ionization chamber

70
New cards

Regulation requiring dose calibrator assay of every dose

10 CFR 35.60

71
New cards

1 mCi equals

37 MBq

72
New cards

1 Ci equals

3.7 × 10^10 Bq

73
New cards

Dose calibrator constancy test frequency

Daily

74
New cards

Dose calibrator linearity test frequency

Quarterly

75
New cards

Dose calibrator accuracy test frequency

Annually

76
New cards

Dose calibrator geometry test frequency

At installation and after repair

77
New cards

Acceptance tolerance for all dose calibrator QC tests

±10%

78
New cards

Sources used for dose calibrator accuracy

Co-57, Cs-137, Co-60

79
New cards

Dose calibrator test checking correct reading across activity levels

Linearity

80
New cards

Dose calibrator test checking volume/container effects

Geometry

81
New cards

Failed linearity or geometry is handled by

Correction factor

82
New cards

Failed accuracy or constancy is handled by

Repair

83
New cards

Retention period for dose calibrator records

3 years

84
New cards

Reducing agent in Tc-99m cold kits

Stannous ion (Sn2+)

85
New cards

Oxidation state change of Tc with stannous reduction

+7 to +4

86
New cards

Kit that uses unreduced Tc and no stannous

Sulfur colloid

87
New cards

Sulfur colloid preparation reagents

Acid + sodium thiosulfate, then buffer

88
New cards

Cause of oversized sulfur colloid particles

Over-heating or high Al3+

89
New cards

Why not to inject air into a kit vial

Oxidizes stannous, causes free pertechnetate

90
New cards

What the kit vial label does NOT require

Patient name

91
New cards

Cause of high free pertechnetate in a kit

Oxidized stannous ion (incomplete reduction)

92
New cards

Mixing technique for MAA kits

Gentle inversion, never vigorous shaking

93
New cards

USP chapter governing radiopharmaceutical compounding

USP

94
New cards

Volume to draw formula

Volume = activity needed ÷ concentration now

95
New cards

Tc-99m precalibration factor at 2 h

1.259

96
New cards

Tc-99m precalibration factor at 4 h

1.587

97
New cards

Tc-99m decay factor at 2 h

0.794

98
New cards

Tc-99m decay factor at 4 h

0.630

99
New cards

Tc-99m decay factor at 6 h

0.5

100
New cards

Precalibration factor formula

1 ÷ decay factor