1/131
Comprehensive vocabulary flashcards covering architectural planning concepts, National Building Code of the Philippines (PD 1096) provisions, residential spatial guidelines, cultural beliefs, and roof typologies.
Master Plan
A graphical representation of ideation and design concepts applied with accurate measurements and dimensions, serving as a technical guide for building construction.
Form Follows Function
The fundamental design principle asserting that the form, appearance, and aesthetics of a building arise naturally from its intended use, making decorative elements secondary.
Distribution
The systematic arrangement and positioning of rooms and major spaces within a residence to ensure efficiency, coordination, and dynamic spatial relationships.
Functional Zoning
The practice of grouping interior spaces logically by related activities into three primary functional zones: sleeping area, living area, and service area.
Circulation
The system of interior pathways and traffic flow designed to be smooth, continuous, and free of unnecessary turns or obstructions.
Section 808 Window Requirement (Habitable Rooms)
Requires rooms lacking artificial ventilation to have window openings equal to at least 10% of the room's floor area, with an absolute minimum of 1.00sq m.
Section 808 Window Requirement (Service/Wet Rooms)
Requires toilets, bathrooms, and laundry rooms without mechanical ventilation to have an opening area not less than 1/20 of the floor area, and not less than 240sq mm (or 240sq cm).
Emergency Egress Window (NBCP)
A rescue/egress window openable from inside without tools, having a minimum width of 820mm, minimum height of 1.00m, and a maximum sill height of 820mm above the floor.
Media Agua (Eaves / Awnings)
Protective projections over required windows that must maintain a minimum clear distance of not less than 750mm from side and rear property lines.
Vent Shaft (NBCP Section 809)
A vertical air passage requiring a cross-sectional area of at least 1.00sq m per meter of height (never less than 1.00sq m total) and a least dimension of 600mm.
Ventilation Skylight (NBCP Section 810)
A glazed opening on a roof whose glass area equals or exceeds the replaced window area, equipped with movable sashes or louvers matching the openable area of the window.
Air Changes per Hour (ACH) Rule of Thumb
The mechanical ventilation principle stating that the higher the ceiling of a room, the fewer the air changes per hour needed.
Section 806 Minimum Room Dimensions (Human Habitation)
Requires rooms intended for human habitation to have a minimum floor area of 6.00sq m and a least horizontal dimension of 2.00m.
Section 806 Minimum Room Dimensions (Kitchen)
Requires a minimum floor area of 3.00sq m with a least horizontal dimension of 1.50m.
Section 806 Minimum Room Dimensions (Bath and Toilet)
Requires a minimum floor area of 1.20sq m with a least horizontal dimension of 900mm.
Section 807 Air Space Requirements
Mandates minimum air volume per occupant: 3.00cu m for school classrooms (1.00sq m floor area per person), 12.00cu m for workshops/offices, and 14.00cu m for habitable rooms.
Setback
The required open distance between a structure and the property boundaries to provide necessary space for safety, light, ventilation, and emergency access.
R-2 and R-3 Maximum Grade Front Setback
A total ground-level front setback of 8.00m (3.00m+5.00m) configured to accommodate off-street parking outside the standard front yard.
Building Orientation
The strategic positioning of a building and its rooms relative to the sun's path and prevailing wind patterns to manage thermal comfort and natural light.
Service Area Orientation
Locating service areas (kitchen, laundry, bathrooms) facing west to allow afternoon solar exposure to reduce moisture and inhibit bacterial growth.
Section 805 Ceiling Height (Multi-Storey Buildings)
Mandates a minimum ceiling height of 2.70m for the first storey, 2.40m for the second storey, and 2.10m for succeeding storeys.
Section 805 Ceiling Height (Mezzanine Floors)
Mandates a minimum clear vertical distance of 1.80m both above and below the mezzanine floor surface.
Convenience Outlet Placement Standards
Installing electrical receptacles approximately 30cm above the finished floor line and within a maximum distance of 1.00m from the serviced appliance.
Door Jamb Wall Clearance
The required minimum distance of 0.20m from the door jamb to the finished wall face to ensure unobstructed swing clearance.
Oro, Plata, Mata
A traditional Filipino belief system where staircase steps are counted consecutively as gold (oro), silver (plata), and death (mata), avoiding terminating on mata.
Feng Shui
The ancient Chinese geomantic discipline (literally translating to 'wind-water') dedicated to aligning man-made structures harmoniously with cosmological and environmental energies.
Type I Construction (NBCP)
A building classification consisting primarily of wood construction permitted by the National Building Code.
Type II Construction (NBCP)
Wood frame construction reinforced with protective fire-resistant materials, rated one-hour fire-resistive throughout.
Type III Construction (NBCP)
A combination of masonry and wood construction that is one-hour fire-resistive throughout, with exterior walls composed of incombustible fire-resistive materials.
Type IV Construction (NBCP)
Structures composed of steel, iron, concrete, or masonry, featuring walls, ceilings, and permanent partitions of incombustible fire-resistive construction.
Type V Construction (NBCP)
Heavy-duty structural assemblies of steel, iron, concrete, or masonry engineered to be four-hour fire-resistive throughout.
Foyer
A central reception area or vestibule positioned as the primary circulation hub immediately connecting entrance points to living spaces and stairways.
Lanai
A roofed patio, inset loggia, or outdoor dining extension common in warm climates that links indoor living spaces with the back porch or garden.
Paseo
An exterior residential walkway designed to link the front porch directly to the rear service porch.
Clean Kitchen (Main Kitchen)
A formal kitchen dedicated to light food preparation, baking, salads, pastries, and specialty dishes.
Dirty Kitchen (Secondary Kitchen)
A secondary utility kitchen designated for routine daily cooking, dishwashing, and heavy-duty meal preparation.
Powder Room
A guest-accessible dry comfort room containing a toilet and washbasin but purposefully built without a shower or bathing facility.
Carport vs. Garage
A carport is an open-sided vehicle shelter, whereas a garage is an enclosed, walled vehicular structure that frequently contains storage and tool areas.
Gable Roof
A pitched roof featuring two opposing sloped surfaces meeting at a central ridge, bordered on each end by a triangular vertical wall (gable).
Box Gable Roof
A variation of the gable roof engineered without rafter overhangs at the gable ends, keeping the roof line completely flush with the end walls.
Dutch Gable Roof
A composite roof featuring a hip roof profile on all four sides topped by a smaller gable structure at the ridge line.
Jerkinhead Roof
A gable roof whose triangular ridge end is clipped or hipped downward to reduce wind resistance and soften the gable crest.
Saltbox Roof
An asymmetrical pitched roof characterized by one short slope on the front side and a continuous, long slope reaching low toward the rear.
Gambrel Roof
A barn-style roof having two slopes on each side of the ridge, where the lower pitch is much steeper than the shallow upper pitch.
A-Frame Roof
A steeply angled triangular gable roof that extends continuously from the roof peak down to the ground, serving as both ceiling and exterior walls.
Mansard Roof
A four-sided French hip roof where each side possesses a double slope, with the lower slope significantly steeper than the upper slope to create usable attic space.
Butterfly Roof
An inverted, V-shaped roof design created by two surfaces pitching inward toward a central valley trough.
Sawtooth Roof
An industrial multi-ridge roof profile alternating steep glazed vertical faces for daylighting with gently sloping opaque planes.
Clerestory Roof
A dual-level roof construction separated by a vertical wall containing a continuous band of windows to admit natural overhead light.
Monitor Roof
A pitched roof featuring an elevated clerestory or raised lantern structure along the central ridge line to permit enhanced ventilation and illumination.
Master Plan
A graphical representation of ideation and design concepts, applied with accurate measurements and dimensions, serving as a technical guide for the construction of a building.
Form Follows Function
The fundamental architectural design principle stating that a building's shape, appearance, and aesthetics arise naturally from its intended practical purpose, with decorative elements being secondary.
Distribution
The systematic spatial arrangement and placement of rooms and functional areas within a residence to ensure efficiency, coordination, and practical relationships between spaces.
Functional Zoning
The logical grouping of residential areas based on related activities into three primary functional zones: Sleeping area, Living area, and Service area.
Circulation
The continuous, smooth, and direct pathways planned inside a structure to provide convenient, safe, and unobstructed movement for occupants.
NBCP Section 808 Window Opening Rule
A National Building Code rule requiring rooms without artificial ventilation to have window openings totaling at least 10% of the room's floor area, with an absolute minimum of 1.00sq m.
NBCP Section 808 Wet Area Window Requirement
The ventilation standard requiring toilets, bathrooms, and laundry rooms to have window openings of not less than 201 of the floor area, and not less than 240sq mm opening directly to an exterior court, yard, street, or watercourse.
NBCP Section 808 Roofed Porch Ventilation Criteria
The standard allowing required windows to open into a roofed porch provided the porch has a ceiling height of at least 2.70m, abuts a legal open space, and has one of its longer sides at least 65% open and unobstructed.
Media Agua Setback
The legal requirement that eaves, canopies, and awnings positioned over required windows must maintain a clearance of not less than 750mm from side and rear property lines.
Emergency Egress Window
An operable opening for escape or rescue that requires no tools to open from the inside, possessing minimum clear dimensions of 820mm in width, 1.00m in height, and a sill height of no more than 820mm above the floor.
NBCP Section 809 Vent Shafts
Vertical ventilation shafts requiring a horizontal cross-section of at least 1.00sq m for every meter of height (never less than 1.00sq m total) and a least dimension of not less than 600mm.
NBCP Section 809 Horizontal Air Ducts
Air intake ducts opening to a street or court with an unobstructed cross-section of at least 0.30sq m, a minimum dimension of 300mm, and intake openings placed at least 300mm above the exterior street or court grade.
NBCP Section 810 Ventilation Skylights
Overhead glazed openings that must provide a glass area not less than the required windows they replace, equipped with movable sashes or louvers whose aggregate net free area matches the replaced openable area.
NBCP Section 811 Artificial Ventilation Rule
A regulatory mandate requiring rooms with industrial or heating equipment to feature mechanical ventilation to eliminate excessive hot or polluted air, operating on the principle that higher ceiling heights require fewer air changes per hour.
Rooms for Human Habitation (NBCP Section 806)
Habitable residential spaces requiring a minimum floor area of 6.00sq m with a least horizontal dimension of 2.00m.
Kitchen Dimensions (NBCP Section 806)
Food preparation areas requiring a minimum floor area of 3.00sq m and a least horizontal dimension of 1.50m.
Bath and Toilet Dimensions (NBCP Section 806)
Sanitary rooms requiring a minimum floor area of 1.20sq m with a least horizontal dimension of 900mm.
School Room Air Space Requirement (NBCP Section 807)
A statutory volume requirement stipulating a minimum of 3.00cu m of air space per person alongside 1.00sq m of floor area per person.
Workshops, Factories, and Offices Air Space (NBCP Section 807)
Occupational working environments requiring a minimum air volume of 12.00cu m per person.
Habitable Room Air Space (NBCP Section 807)
Standard residential rooms requiring a minimum internal volume of 14.00cu m of air space per occupant.
R-1 Minimum Setbacks
Zoning setbacks for low-density residential zones requiring a minimum front yard of 4.50m, a side yard of 2.00m, and a rear yard of 2.00m.
Grade Front Setback for R-2 Max and R-3 Max
A total front setback of 8.00m at natural ground level, calculated as 3.00m+5.00m to accommodate parking outside the yard, while upper floors comply with a 3.00m setback.
Commercial Classification Threshold for R-5
A building zoning rule stating that an R-5 mixed-use structure is legally classified as commercial if at least 55% of its Gross Floor Area (GFA) is dedicated to commercial use.
Bedroom Orientation
The architectural guideline directing bedrooms away from the direct afternoon sun to prevent unwanted solar heat gain during daytime rest and evening cooling.
Service Area Orientation
The architectural guideline orienting kitchens, laundries, and bathrooms toward the west so afternoon ultraviolet sunlight reduces moisture and retards bacterial growth.
Ceiling Height: Naturally Ventilated Rooms (NBCP Section 805)
The standard specifying that rooms relying solely on natural ventilation must have a minimum ceiling height of 2.70m.
Ceiling Height: Multi-Storey Buildings (NBCP Section 805)
The statutory ceiling heights prescribing a minimum of 2.70m for the first storey, 2.40m for the second storey, and 2.10m for all succeeding upper storeys.
Ceiling Height: Mezzanine Floors (NBCP Section 805)
The minimum vertical clear height requirement of 1.80m measured both above and below the intermediate mezzanine level.
Convenience Outlet Placement
The electrical guideline specifying that wall sockets should be positioned approximately 30cm above the finished floor line and located no further than 1.00m from the serviced appliance.
Door Jamb Wall Clearance
A spatial clearance rule requiring an unobstructed distance of at least 0.20m from the door jamb to the finished perpendicular wall to ensure full door-swing operation.
Type I Construction
A building classification under NBCP Section 401 consisting of wood construction where structural components can be made of any code-approved building material.
Type II Construction
A construction type under Section 401 using wood framing reinforced with fire-resistant materials to achieve a uniform one-hour fire-resistive rating throughout.
Type III Construction
A construction type combining masonry and timber framing that provides one-hour fire resistance throughout, featuring exterior walls made of non-combustible, fire-resistive materials.
Type IV Construction
A classification requiring structural members of steel, iron, concrete, or masonry, featuring permanent partitions, ceilings, and walls of incombustible fire-resistive materials.
Type V Construction
The highest structural fire-rating classification under Section 401 of the NBCP, requiring steel, iron, concrete, or masonry elements that are four-hour fire-resistive throughout.
NBCP Section 402 Exception
A regulatory exception permitting a building's construction type to change without full compliance if the Building Official determines the proposed construction is less hazardous to life and fire safety.
Porch
A sheltered transition space guarding the main entryway from weather, typically aligned with prevailing breezes and visible from the front boundary or gate.
Foyer
An entrance vestibule or reception space serving as the house's primary circulation nexus, affording direct access to staircases and main public rooms.
Lanai
An open or semi-enclosed covered living space (or inset balcony/loggia) extending from the dining area toward the garden or porch, suited for tropical climates.
Paseo
A dedicated outdoor linear walkway providing continuous exterior passage connecting the front porch to the rear porch of a residence.
Powder Room
A secondary, visitor-accessible half-bathroom containing a toilet and wash basin without any shower or bathing facilities (also called a dry CR).
Clean Kitchen
The formal main indoor kitchen used for light meal preparation, baking pastries, assembling salads, or serving specialty dishes.
Dirty Kitchen
A heavy-use auxiliary or secondary kitchen designated for everyday cooking, washing greasy cookware, and standard messy utility tasks.
Breakfast Nook
A compact dining alcove or counter area designed for fast, informal family dining, commonly sited adjacent to a window offering outdoor views.
Carport
An open-sided covered automotive shelter that can double as a flexible venue for assorted domestic outdoor chores and activities.
Garage
A fully enclosed, securable vehicular storage space often incorporating built-in workbenches, equipment closets, and home utility storage.
Pantry
A dedicated, well-ventilated storage room for dry groceries, provisions, utensils, and cold goods, situated adjacent to the primary or dirty kitchen.
Oro, Plata, Mata
A traditional Filipino cultural belief that stair steps should be counted sequentially as gold (oro), silver (plata), and death (mata), avoiding layouts where the terminal top step ends on mata.
Padugo
A northern Filipino folk ritual where blood from a slaughtered animal (usually a chicken) is sprinkled on corner posts or foundation trenches to appease local ground spirits.
Feng Shui
The traditional Chinese geomantic discipline (meaning 'wind-water') that governs spatial orientation, layout, and placement of structures to encourage auspicious cosmological energy and prosperity.