1
New cards

Plumbing

________ is defined as the art and science of installing pipes, fixtures, and other apparatus to convey and supply water in buildings and to dispose and discharge waste water and other liquids, gases, and other substances out of buildings in a safe, orderly, healthy, and sanitary way to ensure the health and sanitation of life and property.

2
New cards

Plumber

________ is a title given to a person who is skilled in the field of sanitation.

3
New cards

Plumbarius

________ refers to an individual who worked in the sanitary field of ancient Rome.

4
New cards

Plumbum

________ meant lead. A metal used as plumbing material by the Romans, preferred for tis twin properties of malleability and resistant to acid.

5
New cards

Solid Waste

________ are waste being discharged by water closet.

6
New cards

Liquid Waste

________ are waste coming from various fixtures.

7
New cards

Waste Pipe

________ is any pipe that conveys waste from various fixtures other than water closet.

8
New cards

Soil Pipe

________ is any pipe that convey waste coming from water closet.

9
New cards

Drainage Installation

________ is sometimes referred to as DWV.

10
New cards

Drainage, Waste, and Ventilation

DWV stands for ________.

11
New cards

Air Gap

________ is the unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture, or other device and the flood level rim of the receptacle.

12
New cards

Backflow

________ is the flow of water, or other liquid mixture or substances into the distributing pipes of a potable supply of water from any source, other than its intended source.

13
New cards

Back Siphonage

________ refers to the backflow of used, contaminated, or polluted water from a plumbing fixture or vessel into a water supply pipe due to a negative pressure in such a pipe.

14
New cards

Battery of Fixture

________ refers to any group of two or more similar adjacent fixtures which discharges into a common horizontal waste pipe or soil branch.

15
New cards

Bib

________ is synonymous with faucet, cock, tap, plug, etc. The word faucet is preferred.

16
New cards

Blind Flange

________ is a flange that closes the end of a pipe. There is no opening for the passage of water.

17
New cards

Blow Off

________ is a controlled outlet on a pipeline used to discharge water.

18
New cards

Branch

________ is any part of piping system other than the main riser or stack.

19
New cards

Branch Interval

________ is the length of a soil or waste stack corresponding in general to a storey height, but in no case less than 2.40m within which the horizontal branches from one floor or storey of a building are connected to the stack.

20
New cards

Branch vent

________ is a vent connecting one or more individual vents with a vent stack or stack vent.

21
New cards

Caulking

________ is plugging an opening with oakum, lead, or other materials that are pounded into the space or opening.

22
New cards

Circuit Vent

________ is a branch vent that serves two or more traps, and extends from the front of the last fixture connection of a horizontal branch to the vent stack.

23
New cards

Continuous Vent

________ is a vertical vent that is a continuation of the drain to which the vent connects.

24
New cards

Combination Fixture

________ is a fixture combining one sink and tray, or two or three compartment sink or tray in one vent.

25
New cards

Combination Waste and Vent System

________ is a specially designed system of waste piping embodying the horizontal wet venting of one or more sinks or floor drains by means of a common waste and vent pipe adequately sized to provide free movement of air above the flow line of the drain.

26
New cards

Common Vent

________ is a drain from two or three fixture connected to a single trap. It is also called the dual vent.

27
New cards

Cross Connection

________ is any physical connection between two otherwise separate piping system, one contains potable water, and the other from unknown or questionable safety, whereby, water may flow from one system to the other direction of flow depending on the pressure differential between the two systems.

28
New cards

Dead End

________ is the extended portion of a pipe that is closed at one end permitting the stagnation of water or air therein.

29
New cards

Developed Length

________ is the length along the center of the pipe and fitting.

30
New cards

Diameter

________ of a pipe or tube refers to the nominal internal diameter (ID) of such pipe, except brass and copper tube where the term refers to the outside diameter (OD) of the pipe.

31
New cards

Drainage System

________ includes all piping within the public or private premises that conveys sewage, rainwater, or other liquid waste to a legal point of disposal. It does not include the mains of public sewer system, private or public sewerage treatment or disposal plant.

32
New cards

Dry Vent

________ is a vent that does not carry water or water borne wastes.

33
New cards

Effective Opening

________ is the minimum cross sectional area at the point of water supply discharge, measured or expressed in terms of diameter of a circle. If the opening is not a circle, the diameter of a circle that is equivalent to the cross sectional. (This is applicable to air gap).

34
New cards

Existing Work

________ shall apply to that portion of plumbing system that has been installed and approved prior to the contemplated addition, alteration or correction.

35
New cards

Fixture Branch

________ is a pipe connecting several fixtures.

36
New cards

Fixture Drain

________ is the drain from the trap of a fixture to the junction of that drain with any other drain pipe.

37
New cards

Fixture Units

________ is a quantity in terms of which the load producing effects on the plumbing system of different kinds of plumbing fixtures are expressed on some arbitrarily chosen scale.

38
New cards

Fixture Unit Flow Rate

________ is the total discharge flow in gallons per minute of a simple fixture divided by 7.5 gallons that provides the flow rate of that particular plumbing fixture as a unit of flow. Fixtures are rates as multiple of this unit of flow.

39
New cards

Flood Level

________ is a device located inside the tank for the purpose of maintaining water level for effective flushing of the water closet.

40
New cards

Ferrule

________ is a metallic sleeve called or otherwise joined to an opening in pipe into which a plug is screwed that can be removed for the purpose of cleaning or examining the interior of the pipe.

41
New cards

Flush Valve

________ is a device located at the bottom of the tank for flushing water closets and similar fixtures.

42
New cards

Flushometer Valve

________ is a device which discharges a predetermined quantity of water to the fixture for flushing purposes activated by direct water pressure.

43
New cards

Grade

________ is the slope or fall of pipe in reference to a fraction of an inch per foot length of pipe.

44
New cards

Group Vent

________ is a branch vent that performs its function for two or more traps.

45
New cards

Horizontal Pipe

________ means any pipe or fitting which makes an angle of more than 45 deg with the vertical.

46
New cards

Invert

________ is the lowest portion of the inside of any pipe or conduit that is not vertical.

47
New cards

Liquid Waste

________ is the discharge from any fixture, appliance, or appurtenance in connection with a pluming system which does not receive fecal matter.

48
New cards

Local Vent Pipe

________ is a pipe on the fixture side of the trap through which vapour or foul air is removed from a room or fixture.

49
New cards

Looped Vent

________ is the same as circuit vent except that it loops back and connects with a stack vent instead of a vent stack.

50
New cards

Lateral

________ in plumbing is a secondary pipe. In sewage, a common sewer to which no other common sewer is tributary. It receives sewage only from building sewer.

51
New cards

Main

________ is the principal artery of the system to which branches may be connected.

52
New cards

Main Sewer

________ is a sewer line or system directly controlled by public authority.

53
New cards

Main Vent

________ is the principal artery of the venting system to which vent branches may be connected.

54
New cards

Plumbing Fixtures

________ are installed receptacles, devices, or appliances which are supplied with water, or which receives or discharges liquid or liquid borne waste, with or without discharge into drainage system which maybe directly or indirectly connected.

55
New cards

Plumbing System

________ includes the water supply distribution pipes, plumbing fixtures and traps; soil, waste, and vent pipes; house drain and house sewers including their respective connections, devices and appurtenances within the property lines of premises; and water treating or water using equipment.

56
New cards

Public Sewer

________ is a common sewer directly controlled by public authorities where all abutters have equal rights of connection.

57
New cards

Relief Vent

________ provides circulation of air between drainage and vent systems.

58
New cards

Re-vent Pipe

________ (sometimes called individual vent) is the part of the vent pipeline which connects directly with an individual waste or group of wastes, underneath or back of the fixture, and extend either to the main or branch vent pipe.

59
New cards

Riser

________ is a water supply pipe which extends vertically one full storey or more to convey water to branches or fixtures.

60
New cards

Rough-In

________ is the installation of all parts of the plumbing system which can be completed prior to the installation of fixtures. This include drainage, water supply, vent piping and the necessary fixture supports.

61
New cards

Return Bend

An open ________ usually with inside threads, but applied also to a 180 deg bend in pipe.

62
New cards

Sanitary Sewage

________ is sewage containing human excrement and liquid household waste. It is also called domestic sewage.

63
New cards

Sanitary Sewer

________ is a sewer intended to receive sanitary sewage with or without industrial wastes and without the admixture of surface water, store water or drainage.

64
New cards

Secondary Branch

________ is any branch in a building drain other than the primary branch.

65
New cards

Sewerage or Sewage Work

________ is a comprehensive term including all construction or collection, transportation, pumping, treatment and final disposition of sewage.

66
New cards

Siamese Connection

________ is a Y connection used on fire lines so that two lines of hose may be connected to a hydrant or to the same nozzle.

67
New cards

Standpipe

________ is a vertical pipe usually used for the storage of water, frequently under pressure.

68
New cards

Side Vent

________ is a vent connecting to the drain pipe through a fitting at an angle not greater than 45 deg to the vertical.

69
New cards

Soil Pipe

________ is any pipe that conveys the discharge of water closets or fixtures having similar functions, with or without the discharge from other fixtures, to the building drains (house drain) or building sewer (house sewer).

70
New cards

Stack

________ is the vertical main of a system of soil, waste or vent pipe.

71
New cards

Stack Group

________ is a term applied to the location of fixtures in relation to the stack so that by means of proper fittings, vents may be reduced to a minimum.

72
New cards

Stack Vent

________ is the extension of a soil or waste stack above the highest horizontal drain connected to the stack. It is sometimes called waste vent or soil vent.

73
New cards

Stack Venting

________ is a method of venting a fixture or fixtures through the soil or waste stack.

74
New cards

Subsoil Drain

________ are underground drain pipes that receive subsurface or seepage water only and convey it to a place of disposal.

75
New cards

Sump

________ is a pit or receptacle at a low point to which the liquid waste are drained.

76
New cards

Trap

________ is a fitting or device so designed as to provide when properly vented a liquid seal that will prevent the back passage of air without materially affecting the flow of sewage through it.

77
New cards

Trap Seal

________ is the maximum vertical depth of liquid that trap will retain, measured between the crown weir and top of the dip of the trap.

78
New cards

Vent Stack

________ is a vertical pipe installed primarily for the purpose of providing circulation of air to different parts of the drainage system.

79
New cards

Vent System

________ is a pipe or pipes installed to provide a flow or circulation of air within the plumbing system to protect trap seals siphoning and back pressure.

80
New cards

Vertical Pipe

________ is a pipe installed in a vertical position or at an angle of not more than 45 deg with the vertical.

81
New cards

Waste Pipe

________ is a pipe that conveys liquid waste from fixture that is free of fecal matter.

82
New cards

Water Distributing Pipe

________ is a pipe that conveys water from the water service pipe to the plumbing fixtures and other water outlets.

83
New cards

Water Service Pipe

________ is the pipe from the water main or other source of water supply to the building served.

84
New cards

Water Supply System

________ consists of the water service pipe, water distributing pipes, and the necessary connecting pipes, fitting, control valves, and all appurtenance in or adjacent to the building or premises.

85
New cards

Wet Vent

________ is a vent that receives discharges from wastes other than water closet.