1/32
Looks like no tags are added yet.
What is duplex imaging?
Simultaneous 2D grayscale and Doppler imaging, either Color or Spectral.
What is triplex imaging?
Simultaneous 2D grayscale, Color Doppler, and Spectral Doppler imaging.
What are the main differences between duplex and triplex?
Duplex uses two imaging modes at once; triplex uses three.
What does Doppler gain control?
The amplification of returning Doppler signals.
What happens when Color Doppler gain is too high?
Color speckling appears outside the vessel.
What happens when Color Doppler gain is too low?
The vessel may not fill completely with color.
What does the G.A.S.S. acronym stand for?
Gain, Angle, Steer, Scale.
What is the purpose of color box steering?
To adjust the angle of the color box to optimize Doppler imaging.
What Doppler angle should be used according to your instrumentation PowerPoint?
Less than 60 degrees.
Why should the Doppler angle be aligned with the vessel?
To obtain more accurate blood flow velocity measurements.
What does the sample volume control?
The specific region from which Doppler signals are collected and analyzed.
What does spectral scale control?
The range of blood flow velocities that can be accurately displayed.
What does the spectral baseline do?
Divides the spectral display into positive and negative Doppler shifts.
How can the baseline and scale help correct aliasing?
By repositioning or expanding the displayed velocity range to reduce wraparound.
What happens when the Doppler angle is greater than 60 degrees?
Velocity measurements become less accurate and may overestimate velocities.
What does the Spectral Doppler Invert control do?
Reverses the displayed direction of the Doppler waveform relative to the baseline.
What is the difference between TGC and LGC?
TGC adjusts gain horizontally by depth; LGC adjusts gain vertically.
What does the Freeze button allow the sonographer to do during Doppler imaging?
Stop the live image to review a frame and make measurements.
What is the difference between Acquire and Freeze?
Freeze stops the image for review; Acquire captures an image or clip.
What does the PW button activate?
Pulsed-Wave Spectral Doppler.
What is the purpose of the color scale?
It controls velocity ranges and relates to the Nyquist limit.
What is the purpose of the spectral angle correction cursor?
It aligns the measurement angle with blood flow to improve accuracy.
What is a common result of improper angle correction?
Incorrect velocity measurements and potentially inaccurate interpretation.
What is the function of Gain in Doppler instrumentation?
Amplifies returning Doppler signals.
What is the function of Color scale in Doppler instrumentation?
Controls the range of velocities represented by color.
What is the function of Baseline in Doppler instrumentation?
Divides spectral display into positive and negative shifts.
What is the function of Steering in Doppler instrumentation?
Adjusts the angle of the color box.
What is the function of PW in Doppler instrumentation?
Activates Pulsed-Wave Spectral Doppler.
What is the function of Sample volume in Doppler instrumentation?
Selects the specific region for Doppler signal collection.
What is the function of Freeze in Doppler instrumentation?
Stops the live image to review and measure.
What is the function of Acquire in Doppler instrumentation?
Captures an image or real-time clip.
What is the function of Depth in Doppler instrumentation?
Adjusts the field of view penetration limit.
What is the function of Focus in Doppler instrumentation?
Improves resolution at a specific image depth.