NMX-AA-179-SCFI-2018 Lecture Review

0.0(0)
Studied by 0 people
call kaiCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/19

flashcard set

Earn XP

Description and Tags

Comprehensive practice flashcards covering the regulatory, technical, and metrological requirements of the Mexican standard NMX-AA-179-SCFI-2018 for measuring national water volumes.

20 Terms

1
New cards

The purpose of the NMX-AA-179-SCFI-2018 standard is to provide ________ in the measured volumes of used, exploited, or harnessed national waters.

certainty

2
New cards

The standard aims to avoid the sub-declaration of water usage and the ________ of the resource.

hoarding

3
New cards

A ________ is a legal entity accredited by the EMA and approved by CONAGUA to handle the selection, installation, and operation of measurement systems.

prestador de servicios integrados

4
New cards

Users of national waters have a legal obligation to transmit their measurement data to the ________.

Comisión Nacional del Agua

5
New cards

The standard defines the constant of acceleration of gravity (gg) as ________.

9.81 m/s29.81\,m/s^2

6
New cards

For subterranean water sources with pressure flow, a meter must be selected for nominal diameters (DN) between ________.

13 mm≤DN≤800 mm13\,mm \leq \text{DN} \leq 800\,mm

7
New cards

In conduits with a diameter greater than 800 mm (DN>800 mm\text{DN} > 800\,mm), the meters must be ________ of the spool (carrete) type.

electromagnetic

8
New cards

According to the Maximum Permissible Error (MPE) for Class 2 meters, the error in the lower flow zone (Q1≤Q<Q2Q_1 \leq Q < Q_2) must be ±________ %.

55

9
New cards

For the upper flow zone (Q2≤Q≤Q4Q_2 \leq Q \leq Q_4), the MPE for Class 2 meters at temperatures between 0.1 ∘C0.1\,^{\circ}C and 30 ∘C30\,^{\circ}C is ±________ %.

22

10
New cards

The ratio of the transition flow to the minimum flow rate (Q2/Q1Q_2 / Q_1) is specified as ________.

1,61,6

11
New cards

The ratio for the maximum extraordinary operating flow to the maximum operating flow (Q4/Q3Q_4 / Q_3) is specified as ________.

1,251,25

12
New cards

The periodic verification for volumetric meters with moving parts (such as propellers or turbines) must be conducted every ________.

year

13
New cards

Meters without moving parts (such as electromagnetic or ultrasonic) must undergo periodic verification every ________ year(s).

seven

14
New cards

An initial verification must be performed within ________ natural days following the installation of a new or repaired meter.

30

15
New cards

The measurement system's non-volatile memory must be capable of storing and keeping data accessible for a minimum of ________ year(s).

five

16
New cards

The cabinet used to protect the electronic components must comply with NEMA-4X or ________ standards.

IP-66

17
New cards

To prevent condensation inside the cabinet, the user must place at least ________ of desiccant material such as silica gel.

200 g200\,g

18
New cards

The data transmission unit can send information to the authority via File Transfer Protocol (FTP) or ________.

short message service (SMS)

19
New cards

The NMX-AA-179-SCFI-2018 standard is ________ to any international standard because none existed at the time of its creation.

Not equivalent (NEQ)

20
New cards

An ultrasonic flowmeter configuration consisting of a single pair of sensors with one trajectory for pressure piping is abbreviated as ________.

ATTC