1/27
Vocabulary and key technical terms derived from the Industrial Wastewater Topic Study Guide covering sampling, calculations, treatment operations, chemistry, safety, and regulatory compliance.
Polymer Dilution Formula
A calculation method used to determine the volume of a concentrated polymer needed to prepare a lower concentration solution; for example, 60mL of a 20% polymer solution is needed to prepare 12,000mL of a 0.1% solution.
Concentration in Parts Per Million (ppm)
A unit of concentration where 1% equals 10,000ppm; for example, a 34% solution is equal to 340,000ppm.
Total Suspended Solids (TSS) Calculation
A laboratory measurement of suspended solids calculated using the tare weight of a dried pad and the final weight after filtering a sample; for a 55mL sample with a tare weight of 0.1123g and final weight of 0.1452g, the resulting TSS is 598mg/L.
Rapid Mix Stage
The initial stage of a Jar Test where rapid mixing encourages the dosed coagulant to come into contact with solids to begin forming pin floc.
Clarifier Short Circuiting
A hydraulic condition in a clarifier caused by uneven settling or leaning (e.g., by 10∘), leading to sludge flowing toward the lower elevation side.
Chemical Oxygen Demand (COD)
The analytical test that best indicates the direct impact industrial waste will have on a municipal plant.
DAF Air Saturation
An operational process control strategy in Dissolved Air Flotation (DAF) systems where air saturation is increased to prevent solids from settling in the tank.
Flow Proportion Composite Sample
A composite sampling technique where sample volumes vary with flow; advantageous over a grab sample because as flow increases, contaminants increase, making the sample more representative.
Hypochlorous Acid Reaction (Chlorine in Water)
The chemical process where adding chlorine to water releases Hypochlorous Acid, which increases hydrogen ion concentration and consumes alkalinity, causing the pH to drop.
Cationic Coagulant
A positively charged chemical agent, such as Ferrous Sulfate, used to settle out colloidal solids that carry an anionic (negative) charge in wastewater.
Alkalinity Contributors
Chemical compounds including Calcium Carbonate, Magnesium Carbonate, and Hydroxide that together contribute alkalinity to water.
Ferric Chloride Sludge Production
A chemical characteristic of Ferric Chloride relative to Alum, where a major disadvantage of using Ferric Chloride for solids settling is that it produces more waste sludge.
Van der Waal Force
The physical attractive force between colloidal solids that flocculants such as Aluminum Sulfate and Ferric Chloride work to increase.
Hydrogen Sulfide (H2S) Hazards
Hazards associated with hydrogen sulfide gas produced from sulfates, including being flammable and serving as a source of olfactory fatigue.
Sodium Hypochlorite
Commonly known as bleach, a chemical treatment compound that yields Free Residual Chlorine.
Jar Testing Chemical Verification
An operational advantage of performing regular jar testing on newly purchased chemicals to determine whether the reported concentration is accurate.
Class B Fire Extinguisher
An extinguisher classification utilized to extinguish petroleum-related fires in refining facilities.
Tare Weight
The weight of an empty cylinder or vessel that must be known before weighing each cylinder to determine withdrawal rates and chemical usage accurately.
Hydrophilic Desiccant
A moisture-absorbing substance in a desiccator; a color change to a lighter shade indicates that the desiccant was not replaced by the previous shift.
Positive Displacement Pump Discharge Valve
A discharge valve that, if closed during pump operation, will cause failure of the pump and components due to extreme pressure.
Chlorine Cylinder Wrench Location
A safety requirement specifying that the wrench used for opening and closing a chlorine cylinder must always be firmly fitted on the stem at the top of the cylinder in use.
Resource Conservation and Recovery Act (RCRA)
Federal environmental legislation that governs the cleanup of leaking underground storage tanks and classifies toxic heavy metals such as Cadmium and Arsenic.
Clean Water Act (CWA)
Federal legislation governing discharge limits and reporting guidelines, under which state-issued permits can and usually will be more strict.
Backflow Assembly Device
A mechanical device whose primary purpose is to prevent the mixing or cross-connection of potable and non-potable water sources.
40 CFR 136
The Code of Federal Regulations section where an operator looks to find approved laboratory analytical methods.
Oil and Grease Sample Container Standard
A protocol requiring that oil and grease samples never be taken in plastic bottles because most plastic is petroleum-based and will bind with the oil and grease in the sample.
Voltage
An electrical parameter that measures the pressure of an electrical current.
Preventative Maintenance Program
A proactive maintenance strategy that includes lubricating equipment based on the O&M schedule, vibration testing, and thermal imaging.