what type of supervision is required in ct
direct supervision
how many hours of education (distributed over 4 different subject matters) are required by the arrt for you to sit for the ct registry
16 hours
how many ct numbers are required by the arrt for you to sit for your registry
125
how many ct numbers are required for us to get in ct clinical this semester
50
what is the maximum number of each ct exam that you can record for the arrt post primary certification
5
what is the total number of objectives you will need to turn in for ct this semester
4
what is the total number of evaluations you will need to get in ct this semester
2
what requires direct supervision in ct
contrast administration
venipuncture
scanning
what does tomo mean
to cut, section, or slice
what are the 3 advantages of ct over conventional radiography
superior image quality
no superimposition
ability to differentiate between small differences in densities
what direction does the x axis on ct axes move
right to left
what direction does the y axis on ct axes move
anterior to posterior
what direction does the z axis on ct axes move
superior to inferior
what is the point that all 3 axes meet
orgin
which axes make up a pixel
2D
x and y
which axes make up a voxel
3D
x, y, and z
if given a matrix size of 512 be able to calculate the number of pixels
512 × 512 = 262,144
what is beam attenuation
the reduction of xray as it passes through matter
what are the 3 things that can happen when xray photons pass through matter
absorption
scatter
penetration
what are the 3 properties of matter that affect the number of photons that interact with matter
density
thickness
atomic number of tissue
what is the effect of increasing these properties on the number of photons that interact with matter
if increased= more is reduced and it appears white
what is the definition of linear attenuation coefficient
the amount of xray beam that is scattered or absorbed per unit thickness of the absorber
what can a technologist do to change/affect attenuation (factor)
kVp
what are the shades of gray/ct numbers called in ct
hounsfield units (Hu)
what is the ct number for bone
+1000
what is the ct number for water
0
what is the ct number for air
-1000
what is used to compare the linear attenuation coefficient to to assign a housfield unit
water
what postprocessing tool can be used to determine the ct number of an area and the standard deviation of the pixels within in
ROI
what does polychromatic mean related to the xray beam
an xray beam that is composed of photons with varying energies
what is beam hardening
an artifact in ct that happens when you have a body part that is very dense
where is beam hardening seen on a head ct
seen on the base of the skull through the petrous ridge area
what are the 2 benefits of filtering the low energy, long wavelength xray photons from the beam
reduces beam hardening (artifact) and reduces patient dose
what is volume averaging
how many photons your averaging in your pixel
how can volume averaging be reduced
by using a smaller pixel size (reducing the 3rd dimension) USING THINNER SLICES
what is raw data
all measurements that have been taken
not processed yet
what is image data
data included in the image after the computer has processed it and assigned a Hu
what is prospective reconstruction
images that come up right after scanning
what is retrospective reconstruction
the reconstructed image
uses raw data to make a new image
what is the scanning method that is used when the patient table moves continuously through the ct scanner during the scan
helical/spiral scanning
what material is the ct table made of and why
carbon graphite fiber because it doesnt absorb xray
what is the term for the the degree to which a ct table can move horizontally which determines the extent a patient can be scanned without repositioning
scannable range
what is the term for the process of moving the table by a specified measure
table incrementation
what is the smallest measurement of table movement that is required to be able to be reproduced
1 mm
what is it called when the technologist uses an anatomic landmark to set the table position
table referencing
which side is the right side when looking at an axial CT image
the right side is my left side when looking at it and vice versa

what image plane is this
axial

what image plane is this
coronal

what image plane is this
sagittal
which image orientation is acquired from the original ct scan
axial
which image orientations are created through post processing
sagittal and coronal