1/20
Looks like no tags are added yet.
What is the purpose of a titration in volumetric analysis?
To determine the concentration of an unknown solution by reacting it with a solution of known concentration
What type of reaction is typically involved in an acid-base titration?
A neutralisation reaction
What is the equivalence point in a titration?
The point at which the acid and base have reacted in exact stoichiometric proportions
What is the difference between the equivalence point and the end point of a titration?
The equivalence point is the theoretical point of complete reaction; the end point is the point at which the indicator changes colour
What is the role of an indicator in an acid-base titration?
To show when the end point has been reached by changing colour
Why must the indicator chosen for a titration have a colour change that occurs at or very close to the equivalence point?
So that the end point closely matches the equivalence point, giving an accurate result
What piece of apparatus is used to deliver a measured volume of solution in a titration?
A burette
What piece of apparatus is used to measure a fixed volume of solution to be placed in the conical flask?
A pipette
Why is a conical flask used rather than a beaker in a titration?
The conical shape allows swirling without spillage and helps ensure thorough mixing
What is a standard solution?
A solution of accurately known concentration
Why must a primary standard be used to prepare a standard solution for titrations?
Because a primary standard has known purity and can be weighed accurately to prepare a solution of precise concentration
What properties should a primary standard have?
High purity, stability in air, high molar mass, and solubility in water
What is the formula relating moles, concentration and volume?
n = c × V, where n is moles, c is concentration in mol dm⁻³, and V is volume in dm³
How do you convert volume in cm³ to volume in dm³?
Divide the volume in cm³ by 1000
In a titration calculation, how do you determine the number of moles of the unknown substance?
Use the moles of the known substance and the stoichiometric ratio from the balanced equation
What is meant by the titre in a titration?
The volume of solution added from the burette to reach the end point
Why are rough titrations performed before recording accurate titres?
To identify the approximate end point so that subsequent titrations can be performed more carefully near that volume
Why should concordant titres be used when calculating the mean titre?
Because concordant results are consistent and reliable, reducing the effect of random errors
What is meant by concordant results in a titration?
Results that are within 0.10 cm³ of each other
How do you calculate the concentration of an unknown solution from titration data?
Use the mean titre to calculate moles of the known solution, use the stoichiometric ratio to find moles of the unknown, then divide by the volume of the unknown solution to find its concentration
A burette has an uncertainty of ±0.05 cm³ per reading. Calculate the percentage uncertainty in a titre of 25.00 cm³.
A titre is calculated from two burette readings (start and end), so the absolute uncertainty in the titre is 2 × 0.05 = 0.10 cm³. Percentage uncertainty = (0.10 / 25.00) × 100 = 0.40%.