1/25
Vocabulary practice flashcards covering UV-Vis spectrophotometry principles, BeerâLambert Law parameters, purity ratios, and DNA extraction reagents and steps.
UV-Vis Spectrophotometer
An instrument that bombards molecules with light at a specific wavelength, energetically exciting valence electrons in outer orbitals to absorb energy, and measures absorbance to determine the concentration and purity of substances like nucleic acids and proteins.

UV-Vis Spectrophotometer Optical Path
The sequential path traveled by light within the instrument, consisting of the light Source, Entrance slit, Dispersion device (prism), Exit slit, Sample cuvette, and Detector.
Absorbance Spectrum
The graphical profile or output generated when the absorbance of a molecule is examined across multiple wavelengths.

BeerâLambert Law
A mathematical relationship used to calculate the concentration of a molecule with high accuracy: A=ΔbC, where A is absorbance, Δ is molar absorptivity, b is path length, and C is concentration.
Molar Absorptivity (Δ)
The coefficient representing how strongly a chemical species absorbs light at a given wavelength, expressed in units of L/(molâ cm).
Path Length (b or L)
The distance that light travels through the sample inside the cuvette, measured in cm.
Concentration (C)
The amount of solute present in a sample, typically expressed in mol/L.
Protein Maximum Absorbance
The wavelength of maximum light absorption for proteins, which occurs at 280nm (with an additional minor peak observed at 215â230nm).
Nucleic Acid Maximum Absorbance
The wavelength of maximum light absorption for DNA and RNA, which occurs at 260nm.
260/280 Ratio (Pure DNA)
The absorbance ratio used to assess purity, with an accepted value of approximately 1.8 (or 1.7â1.9) for pure DNA.
260/280 Ratio (Pure RNA)
The absorbance ratio for pure RNA, with an accepted value of approximately 2.0, which is higher than DNA due to the higher ratio of Uracil compared to Thymine.
260/280 Ratio (Pure Protein)
The absorbance ratio for pure protein, which has an accepted value of approximately 0.6.
Protein Contamination in PCR
A form of contamination where remaining proteins interfere with the denaturation of template DNA strands and hinder the binding of DNA polymerase.
Protease Contamination in Restriction Digestion
A form of contamination where proteases degrade restriction enzymes, impairing the digestion of DNA.
DNA Digestion/Extraction Buffer
A reagent that lyses open cells to release DNA into solution.
Proteinase K
An enzyme used to digest and break down cellular proteins such as histones, including enzymes that could degrade DNA.
Potassium Acetate
A salt used to precipitate cellular debris for centrifugal separation and to allow DNA to stay tightly bound and precipitate out of solution.
Isopropanol (DNA Extraction)
An alcohol used to precipitate concentrated DNA samples requiring a final concentration of ~35% and 0.5M salt (0.7â1 volumes of sample), but salt can co-precipitate and storage at â20âC is not recommended.
Ethanol (DNA Extraction)
An alcohol used to precipitate short or dilute DNA samples requiring a final concentration of ~75% and 0.5M salt (2â2.25 volumes of sample); storage at â20âC improves precipitation and allows sample storage.
Ice Bath (DNA Extraction)
A cooling step applied to further drive the precipitation of DNA out of solution before pelleting.
Centrifugation (DNA Extraction)
A procedure that spins samples at high speed to separate cellular debris or compact precipitated DNA into a pellet at the bottom of the tube.
TE Buffer
A sterile resuspension buffer added to rehydrate purified DNA and protect it from degradation.
Tris
A buffering agent present in TE buffer that functions to maintain a stable pH.
EDTA
A chelating component of TE buffer that prevents nucleases from chewing up or denaturing DNA.
RNase
An enzyme added to digest and eliminate any co-precipitated RNA from the extracted DNA solution.
Spectrophotometer Blank
A cuvette containing only the solvent (such as TE buffer) used to zero the instrument (0.000) to eliminate any absorbance contributed by the solvent itself.